JPJosé Luiz Rangel Paes

José Luiz Rangel Paes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


José Luiz Rangel Paes has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Experimental analysis of the performance of screwed connections for steel-timber composite beams

    by Jean Antônio Emerick, Humberto Varum, Xavier Romão, Gustavo de Souza Veríssimo, José Luiz Rangel Paes


  • Open Access

    Global Buckling Resistance of Cold-Formed Steel Beams with Omega-Shaped Sections

    by Rita Peres, José Carvalho, Jean Antonio Emerick, Luís Macedo, José Luiz Rangel Paes, José Miguel Castro

    The absence of analytical expressions in current codes for evaluating the critical moment for lateral–torsional buckling of cold-formed beams with omega-shaped sections presents a fundamental challenge when assessing their resistance to global buckling. In response to this challenge, a comparative study was conducted to explore various approaches for calculating the critical moment. This involved both analytical and numerical analyses, using different methods available in codes and computational tools. The analytical analysis followed the Effective Width Method, employing the expression proposed in ENV 1993-1-1:1992, which is commonly used for evaluating the critical lateral–torsional moment of hot-rolled profiles. Numerical analyses were then performed using the ABAQUS v6.13, GBTUL v2.0, and CUFSM v5.05 software packages. The ABAQUS model, validated with results obtained from an experimental campaign, serves as the reference model. Upon assessing the bending moment resistances according to European, Brazilian, and American standards, consistency was found among these standards. However, it became evident that using the analytical expression proposed for hot-rolled profiles is inadequate for evaluating the critical lateral–torsional moment of CFS omega-shaped profiles. Conversely, the agreement between the ABAQUS, GBTUL, and CUFSM results suggests their utility as reliable tools for estimating the elastic critical lateral–torsional buckling moment.


  • Open Access

    Evaluation of the Structural Behavior of Composite Slim-Floor Beams with Openings in the Web

    by Leonardo C. Mesquita, Marília G. Marques, José L. R. Paes

    In this study, the bending behavior of Slim-Floor beams was analyzed using FE models developed in the ABAQUS software. The validity of these models was demonstrated by comparing the numerical results obtained with experimental data found in the literature. Through parametric evaluations, the following findings were verified: (i) the connection mechanisms adopted (concrete dowels, reinforcing steel bars, and adherence) were able to activate the composite behavior between steel and concrete; (ii) the spacing between the openings, the number of openings, and the diameter of the reinforcing steel bars determine the behavior of the connection; (iii) adherence contributes little to the strength of the connection, and therefore, its contribution can be neglected; (iv) the connection mechanisms adopted in this study can promote the ductile behavior of the Slim-Floor beams.


  • Open Access

    Experimental Analysis of Watertightness Performance of Interfaces between Masonry and Steel Structures Subjected to Accelerated Aging

    by Alex de Freitas Bhering, Rayane Neves Franco, Mariana Araújo dos Santos, Lorena de Melo Sathler, Leonardo Gonçalves Pedroti, Humberto Varum, Gustavo de Souza Veríssimo, José Luiz Rangel Paes

    Steel buildings often experience failure at the interfaces between their vertical exterior enclosure systems (VEESs) and structural elements. This phenomenon generates various pathological manifestations in steel buildings, resulting in the precocious decay of the structure and the diminishment of its service life. The treatment of these interfaces is essential for ensuring their proper performance and watertightness, and to protect the durability of the steel structure. This paper proposes a method for treating common interface joints between masonry and steel structures with the application of an EPDM (ethylene propylene diene monomer) elastomer membrane. The main goal of this building technique is to ensure the durability and watertightness of the interface’s joints when they are subjected to aging triggered by heat exposure and thermal shock. The experimental models tested consisted of a steel frame and a conventional masonry vertical enclosure system with ceramic blocks plastered with cement mortar. The models were subjected to ten cycles of heat exposure and thermal shock for the purpose of simulating accelerated aging, followed by a watertightness experiment that simulated the action of both rain and wind pressure. The interfaces between masonry and the steel structure proposed in this study allowed adequate differential movements between the parts, without damage to joints and masonry. Only small cracks were observed in the outer test region of all of the interfaces tested. In the regions of the joints treated with the EPDM membrane, no alterations were visible to the naked eye. During the cycles of the heat exposure and thermal shock test, the maximum relative horizontal displacements observed in the joints were 0.743 mm for vertical joints and 0.230 mm for horizontal joints, indicating the accurate reproduction of the behavior expected from an untied interface. The results obtained in the previously mentioned watertightness test showed that no humidity stains were found on the inner face of any of the specimens, even after the continuous application of a pneumatic pressure of 400 Pa for eight hours. Therefore, the results indicated satisfactory performance in terms of durability and watertightness in all evaluated cases, indicating that the application of an EPDM membrane can be effective in preventing water leaks in the interfaces between masonry and steel elements, thus contributing to ensuring the steel structure’s durability.