Abhijeet Gorey
Research Subjects
Research Interests
Abhijeet Gorey has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Arpan Pal
TCS Research, Tata Consultancy Services Limited, Kolkata, India
5 shared publications - Tapas Chakravarty
TCS Research, Kolkata, India
5 shared publications - Chirabrata Bhaumik
TCS Research
4 shared publications - Arijit Sinharay
TCS Research,India
3 shared publications - Subhasri Chatterjee
City, University of London, Research Centre for Biomedical Engineering, London
2 shared publications - Aishani Basu
TCS Research
1 shared publication
Latest Publications
- 4 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (10) , 1-4
Photoacoustic Sensing System for Noninvasive and Real-Time Measurement of Paint's Viscosity in Flowing Conditions
Inline measurement of paint viscosity in the flowing conditions is extremely important for the paint manufacturing industry. This study proposes a non-invasive, cost-effective and inline method to measure paint's viscosity using frequency domain Photoacoustic (PA) sensing. Through a PA signal, three different frequency and time domain features namely spectral amplitude ratio, acoustic attenuation and acoustic wave velocity are extracted. Due to the lower accuracy (<90%) of the aforementioned features, a novel statistical feature i.e. the harmonic mean is derived from the existing features to enhance the accuracy of the measurement. To mitigate the experimental challenges, the viscosity model is trained from the PA data under static condition and tested for the paint under flowing condition. In the flowing conditions, the accuracy in the measurement is found to be less than 93%. Hence, a correction factor is introduced which considers the doppler shift in the PA wave velocity due to the paint flow. With this correction factor, the accuracy of the viscosity measurement is found to be greater than 95%. The developed viscosity model is validated through the 4-fold cross validation and the results are confirmed for their repeatability and tested with different paint samples.
- 4 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (10) , 1-4
Photoacoustic Sensing System for Noninvasive and Real-Time Measurement of Paint's Viscosity in Flowing Conditions
Inline measurement of paint viscosity in the flowing conditions is extremely important for the paint manufacturing industry. This study proposes a non-invasive, cost-effective and inline method to measure paint's viscosity using frequency domain Photoacoustic (PA) sensing. Through a PA signal, three different frequency and time domain features namely spectral amplitude ratio, acoustic attenuation and acoustic wave velocity are extracted. Due to the lower accuracy (<90%) of the aforementioned features, a novel statistical feature i.e. the harmonic mean is derived from the existing features to enhance the accuracy of the measurement. To mitigate the experimental challenges, the viscosity model is trained from the PA data under static condition and tested for the paint under flowing condition. In the flowing conditions, the accuracy in the measurement is found to be less than 93%. Hence, a correction factor is introduced which considers the doppler shift in the PA wave velocity due to the paint flow. With this correction factor, the accuracy of the viscosity measurement is found to be greater than 95%. The developed viscosity model is validated through the 4-fold cross validation and the results are confirmed for their repeatability and tested with different paint samples.
- 17 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Digital Twin Approach for Estimation of Contaminants in Lubrication Oil through Photoacoustic Sensing System
Monitoring the changes in properties of lubricant oil with different contaminants (e.g., soot particles, water, etc.) could be a reliable technique to investigate the faults that arise due to oil contamination aiding to machine maintenance. Photoacoustic sensing system has shown promises to measure such changes, however, the attempts are limited to the collection of a large number of samples for initial calibration and standardization of the process. A digital twin substituting the system may resolve these problems. In the current work, a digital twin for the photoacoustic measurements from lubricant oil has been developed through the process of: 1) designing a simulator, 2) carrying out experiments and 3) training a domain adaptation algorithm using the simulated data and testing with experimental datasets. Analysis has shown an increase in accuracy of approximately 7% for adaptation compared to the no adaptation scenario, and has established a digital twin platform for machine health analysis.
- 17 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
A Digital Twin Approach for Estimation of Contaminants in Lubrication Oil through Photoacoustic Sensing System
Monitoring the changes in properties of lubricant oil with different contaminants (e.g., soot particles, water, etc.) could be a reliable technique to investigate the faults that arise due to oil contamination aiding to machine maintenance. Photoacoustic sensing system has shown promises to measure such changes, however, the attempts are limited to the collection of a large number of samples for initial calibration and standardization of the process. A digital twin substituting the system may resolve these problems. In the current work, a digital twin for the photoacoustic measurements from lubricant oil has been developed through the process of: 1) designing a simulator, 2) carrying out experiments and 3) training a domain adaptation algorithm using the simulated data and testing with experimental datasets. Analysis has shown an increase in accuracy of approximately 7% for adaptation compared to the no adaptation scenario, and has established a digital twin platform for machine health analysis.
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (1) , 1-4
A Compact and Novel Photoacoustic Sensing Technique for In Vitro Characterization of Blood Viscosity: A Phantom-Based Study
The feasibility of continuous wave laser diode based Photoacoustic (CWPA) sensing technique in estimating the blood viscosity, and red blood cell concentration and measuring the blood vessel diameter is demonstrated here. The laser enabled swept frequency acoustic interferometry (LE-SFAI) principle is applied here to obtain the high signal-to-noise ratio CWPA signal. The experiments are performed using the liquid dye-glycerol mixture and further with the tissue mimicking phantoms. Certain distinct features from the time domain CWPA signal are used to estimate the aforementioned parameters. The results are verified by the results obtained from the standard instruments. The usage of a continuous wave laser diode enables a compact and economical photoacoustic (PA) sensing system for blood viscosity characterization and field deployment
- 13 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (1) , 1-4
A Compact and Novel Photoacoustic Sensing Technique for In Vitro Characterization of Blood Viscosity: A Phantom-Based Study
The feasibility of continuous wave laser diode based Photoacoustic (CWPA) sensing technique in estimating the blood viscosity, and red blood cell concentration and measuring the blood vessel diameter is demonstrated here. The laser enabled swept frequency acoustic interferometry (LE-SFAI) principle is applied here to obtain the high signal-to-noise ratio CWPA signal. The experiments are performed using the liquid dye-glycerol mixture and further with the tissue mimicking phantoms. Certain distinct features from the time domain CWPA signal are used to estimate the aforementioned parameters. The results are verified by the results obtained from the standard instruments. The usage of a continuous wave laser diode enables a compact and economical photoacoustic (PA) sensing system for blood viscosity characterization and field deployment
- 22 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (10) , 1-4
Nondestructive Measurement of Microcoating Thickness Using Sweep Frequency Photoacoustic Sensing Technique
Non-destructive and rapid measurement of micro coating thickness is a challenge for most of the paint coating industries. This study proposes a novel sweep frequency photoacoustic sensing technique for the non-destructive estimation of a coating layer thickness. The continuous wave laser diodeused for the sample excitationmakes the overallsystem compact and portable. Also, the usage of frequency sweep enables the technique to be applied to different substrates and different coating layers. The Rosencwaig-Gersho (RG) model is employed to estimate the thickness of the coating layer by measuring the resonance frequency of the photoacoustic wave. Regression analysis is performed to obtain the micro thickness through photoacoustic measurements. The photoacoustic measurements arecompared with the standard (cross-sectional microscopy) thickness measurement technique and the error is found to be less than 5%. The simple computational method and instrumentation used in this technique enable it to be deployed in industries for rapid estimation of the micro thickness.
- 22 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Letters
- Vol. 8 (10) , 1-4
Nondestructive Measurement of Microcoating Thickness Using Sweep Frequency Photoacoustic Sensing Technique
Non-destructive and rapid measurement of micro coating thickness is a challenge for most of the paint coating industries. This study proposes a novel sweep frequency photoacoustic sensing technique for the non-destructive estimation of a coating layer thickness. The continuous wave laser diodeused for the sample excitationmakes the overallsystem compact and portable. Also, the usage of frequency sweep enables the technique to be applied to different substrates and different coating layers. The Rosencwaig-Gersho (RG) model is employed to estimate the thickness of the coating layer by measuring the resonance frequency of the photoacoustic wave. Regression analysis is performed to obtain the micro thickness through photoacoustic measurements. The photoacoustic measurements arecompared with the standard (cross-sectional microscopy) thickness measurement technique and the error is found to be less than 5%. The simple computational method and instrumentation used in this technique enable it to be deployed in industries for rapid estimation of the micro thickness.
- 8 June 2022
- Published by Springer Nature
- p. 247-255
Application of Photoacoustic Sensing in Depicting Viscosity Information of Lubrication Oil
- 8 June 2022
- Published by Springer Nature
- p. 247-255
Application of Photoacoustic Sensing in Depicting Viscosity Information of Lubrication Oil