Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Pedro Castro-Martins has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Usability Evaluation and Perceived Performance of the MoonWalking® Insole in Safety Footwear

    by Pedro Castro-Martins, Arcelina Marques, Luís Pinto-Coelho, Mário Vaz

    Prolonged standing and repetitive lifting are routine occupational stressors that elevate plantar pressures across workers. In those with diabetes, these demands represent additional risk factors for diabetic foot pathology, highlighting the need for ergonomic interventions beyond standard safety footwear. This study evaluated the perceived ergonomic performance of the MoonWalking® insole, a novel adaptive pneumatic system designed for real-time pressure stabilization and offloading when integrated into safety footwear. A comparative experimental protocol tested two conditions: safety footwear with the manufacturer’s original insole and the same footwear with the MoonWalking prototype. Twenty participants assessed perceived comfort using a VAS and binary ergonomic questionnaires. The results showed statistically significant improvements in perceived cushioning, foot fit, and overall comfort when using the MoonWalking insole. Participants consistently identified pressure-stabilizing and offloading functions across all plantar regions, indicating that adaptive pressure control was clearly perceptible. No pain or movement restrictions were reported. Although perceived fatigue did not reach statistical significance, a decreasing trend was observed. A slight reduction in intention to reuse the footwear occurred with the prototype, possibly due to its increased weight. These findings provide evidence that integrating an adaptive pneumatic insole into safety footwear may improve plantar pressure redistribution and user comfort.

  • Open Access

    A Portable Insole System for Actively Controlled Offloading of Plantar Pressure for Diabetic Foot Care

    by Pedro Castro-Martins, Arcelina Marques, Luís Pinto-Coelho, Pedro Fonseca, Mário Vaz

    Plantar pressure monitoring is decisive in injury prevention, especially in at-risk populations such as people with diabetic foot. In this context, innovative solutions such as pneumatic insoles can be essential in plantar pressure management. This study describes the development of a variable pressure system that promotes the monitoring, stabilization, and offloading of plantar pressure through a pneumatic insole. This research was also intended to evaluate its ability to redistribute plantar pressure, reduce peak pressure in both static and dynamic conditions, and validate its pressure measurements by comparing the results with those obtained from a pedar® insole. Tests were carried out under both static and dynamic conditions, before and after the pressure stabilization process by air cells and the subsequent pressure offloading. During the validation process, methods were used to evaluate the agreement between measurements obtained by the two systems. The results of the static test showed that pressure stabilization reduced pressure on the heel by 32.43%, distributing it to the metatarsals and toes. After heel pressure offloading, the reduction reached 42.72%. In the dynamic test, despite natural dispersion of the measurements, a trend to reduce the peak pressure in the heel, metatarsals, and toes was observed. Agreement analysis recorded 96.32% in the static test and 94.02% in the dynamic test. The pneumatic insole proved effective in redistributing and reducing plantar pressure, with more evident effects in the static test. Its agreement with the pedar® system reinforces its reliability as a tool for measuring and managing plantar pressure, representing a promising solution for preventing plantar lesions.


  • Open Access

    Calibration and Modeling of the Semmes–Weinstein Monofilament for Diabetic Foot Management

    by Pedro Castro-Martins, Luís Pinto-Coelho, Raul D. S. G. Campilho

    Diabetic foot is a serious complication that poses significant risks for diabetic patients. The resulting reduction in protective sensitivity in the plantar region requires early detection to prevent ulceration and ultimately amputation. The primary method employed for evaluating this sensitivity loss is the 10 gf Semmes–Weinstein monofilament test, commonly used as a first-line procedure. However, the lack of calibration in existing devices often introduces decision errors due to unreliable feedback. In this article, the mechanical behavior of a monofilament was analytically modeled, seeking to promote awareness of the impact of different factors on clinical decisions. Furthermore, a new device for the automation of the metrological evaluation of the monofilament is described. Specific testing methodologies, used for the proposed equipment, are also described, creating a solid base for the establishment of future calibration guidelines. The obtained results showed that the tested monofilaments had a very high error compared to the 10 gf declared by the manufacturers. To improve the precision and reliability of assessing the sensitivity loss, the frequent metrological calibration of the monofilament is crucial. The integration of automated verification, simulation capabilities, and precise measurements shows great promise for diabetic patients, reducing the likelihood of adverse outcomes.


  • Open Access

    Calibration and Modelling of the Semmes-Weinstein Monofilament for Diabetic Foot Management

    by Pedro Castro-Martins, Luis Coelho, R.D.S.G. Campilho

    Diabetic foot is a serious complication that poses significant risks for diabetic people. The resulting reduction in protective sensitivity in the plantar region requires early detection to prevent the imminent ulceration and amputation. The primary method employed for evaluating this sensitivity loss is the 10 g f Semmes-Weinstein monofilament test, commonly used as a first-line procedure. However, the lack of calibration in existing devices often introduces decision errors due to unreliable feedback. In this paper, a new equipment designed to address these limitations and enhance the assessment of the sensitivity loss using the 10 g f monofilament is introduced. The proposed system automates metrological verification and evaluation processes, ensuring accurate and reliable results. Furthermore, it simulates the practitioner’s procedure, serving both as a valuable training tool and a means to provide force-feedback information. An analytical model of the monofilament buckling and deflection is also presented. The obtained results showed that the tested monofilaments had a very high error compared to the 10 g f declared by the manufacturers. It is aimed, by introducing this advanced equipment, to improve the precision and reliability of assessing the sensitivity loss. The integration of automated verification, simulation capabilities, and precise measurements shows great promise for diabetic patients, reducing the likelihood of adverse outcomes such as ulceration and amputation.


  • Open Access

    In-shoe plantar pressure measurement technologies for the diabetic foot: A systematic review

    by Pedro Castro-Martins, Arcelina Marques, Luís Coelho, Mário Vaz, João Santos Baptista


  • Open Access

    Plantar pressure thresholds as a strategy to prevent diabetic foot ulcers: A systematic review

    by Pedro Castro-Martins, Arcelina Marques, Luís Coelho, Mário Vaz, José Torres Costa


  • Towards an In-Shoe Pneumatic Insole to Plantar Injury Prevention in Diabetic Foot

    by Pedro Castro-Martins, Luís Pinto-Coelho, Mário Vaz, Marcelino Pinto, Arcelina Marques


  • Preliminary Tests with Screen-Printed Piezoresistive Pressure Sensors on PET and Textile Substrates

    by Pedro Martins, Carolina Silva, Juliana Oliveira, Arcelina Marques

    The search for more practical and economically advantageous solutions to produce flexible and printable pressure sensors, is giving rise to new approaches with promising results. The production of conductive and piezoresistive inks for application on flexible and stretchable substrates is a sign of this evolution. In this paper, we propose to analyze the results of some calibration tests, performed with pressure-sensitive piezoresistive sensors screen-printed on PET and textile substrates. The results showed that these sensors generally follow a trend with a strong approximation to the linear model. The textile sensor is the most linear (R2 = 0.99), and PET sensor (S1) has a higher sensitivity (40.4 mV/kPa) than the other sensors. Results obtained are, in general, within the expected behavior for the piezoresistive ink used and allowed for comparing between sensors printed in PET and textile substrates. A positive factor to consider lies in the possibility of using the screen-printing technology on different substrates, preferably in textile fabric.


  • Bring You Own Patient - BYOP Program

    by Pedro Martins, Joaquim Abreu de Sousa