Markoulina Berger-Gryllaki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Markoulina Berger-Gryllaki has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Farshid Sadeghipour
Pharmacy Department, Lausanne University Hospital, Lausanne, Switzerland
3 shared publications - Julian Pezzatti
Pharmacy Department, Lausanne University Hospital, Lausanne, Switzerland
2 shared publications - William Bello
Pharmacy Department, Lausanne University Hospital, Lausanne, Switzerland
2 shared publications - Antoine Pierrot
Pharmacy Department, Lausanne University Hospital, Lausanne, Switzerland
1 shared publication C. Brönnimann
Service de pharmacie, centre hospitalier universitaire Vaudois, Lausanne, Suisse
1 shared publication- Camille Hosotte
Pharmacy Department, Lausanne University Hospital, Lausanne, Switzerland
1 shared publication
Latest Publications
- Open Access
- 19 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 40736
Assessment of leachables in hospital pharmacy compounded topotecan conditioned in common off-label syringes for intravitreal use
Compounding drug products is a vital hospital pharmacy feature that requires safe and compatible primary packaging, particularly for prefilled syringes (PFSs). The off-label use of plastic syringes in batch compounding for intravitreal administration has raised concerns over leachables and silicone oil lubricants, which may migrate into drug solutions and potentially cause toxicity. This study evaluated two widely used off-label plastic syringes, BD Plastipak and BBraun Omnifix, for conditioning with topotecan (TPT), a chemotherapeutic used to treat infant retinoblastoma. Leachables were monitored over 12 months via an original LC‒MS method with postcolumn infusion (PCI), including possible detection of silicone degradants. This approach may serve as an indirect method to assess silicone-related contamination due to the spread of free silicone particulates. Both syringes released low overall levels of leachables. However, BD Plastipak emits five oligomeric degradants, two exceeding permitted daily exposure (PDE) limits. In contrast, BBraun Omnifix showed greater chemical stability, releasing only minimal silicone-related compounds and oleamide, suggesting a lower risk for intraocular use. Although these findings support BBraun Omnifix as a safer option, the findings underscore the need for toxicologically assessed, purpose-designed plastic PFSs made from low-extractable materials such as cyclic olefin polymer (COP) or copolymer (COC) for long-term drug storage.
- 19 November 2025
- Published by Springer Nature in Scientific Reports
- Vol. 15 (1) , 40736
Open AccessAssessment of leachables in hospital pharmacy compounded topotecan conditioned in common off-label syringes for intravitreal use
Compounding drug products is a vital hospital pharmacy feature that requires safe and compatible primary packaging, particularly for prefilled syringes (PFSs). The off-label use of plastic syringes in batch compounding for intravitreal administration has raised concerns over leachables and silicone oil lubricants, which may migrate into drug solutions and potentially cause toxicity. This study evaluated two widely used off-label plastic syringes, BD Plastipak and BBraun Omnifix, for conditioning with topotecan (TPT), a chemotherapeutic used to treat infant retinoblastoma. Leachables were monitored over 12 months via an original LC‒MS method with postcolumn infusion (PCI), including possible detection of silicone degradants. This approach may serve as an indirect method to assess silicone-related contamination due to the spread of free silicone particulates. Both syringes released low overall levels of leachables. However, BD Plastipak emits five oligomeric degradants, two exceeding permitted daily exposure (PDE) limits. In contrast, BBraun Omnifix showed greater chemical stability, releasing only minimal silicone-related compounds and oleamide, suggesting a lower risk for intraocular use. Although these findings support BBraun Omnifix as a safer option, the findings underscore the need for toxicologically assessed, purpose-designed plastic PFSs made from low-extractable materials such as cyclic olefin polymer (COP) or copolymer (COC) for long-term drug storage.
- Open Access
- 23 August 2023
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 236, 115640
Development of a generic approach for monitoring leachable compounds in hospital pharmacy-prepared prefilled plastic packaging by ultrahigh-performance liquid chromatography coupled to high-resolution mass spectrometry with postcolumn infusion
- 23 August 2023
- Published by Elsevier in Journal of Pharmaceutical and Biomedical Analysis
- Vol. 236, 115640
Open AccessDevelopment of a generic approach for monitoring leachable compounds in hospital pharmacy-prepared prefilled plastic packaging by ultrahigh-performance liquid chromatography coupled to high-resolution mass spectrometry with postcolumn infusion