Kiwon Yeom
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kiwon Yeom has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Seho Kim
Department of Human Intelligence and Robot Engineering, Sangmyung University, Cheonan-si 31066, Republic of Korea
2 shared publications - Joong Ho Lee
Department of Game Software, Keimyung University, Daegu 42601, Republic of Korea
1 shared publication Seonil Choi
Sangmyung University - Cheonan Campus
1 shared publication- Seungyeon Shin
Department of Electronic Information System Engineering, Graduate School, Sangmyung University, Cheonan 31066, Republic of Korea
1 shared publication
Latest Publications
- Open Access
Robotic Venipuncture with Sequential Needle-Tip Realignment and Probe-Induced Vessel Displacement Compensation
Robotic venipuncture systems can accurately localize vascular targets using near-infrared (NIR) and ultrasound (US) imaging. However, image-based localization does not guarantee accurate physical needle placement. Residual errors arising from sensor-to-robot registration, mechanical assembly, and needle mounting can cause misalignment of the physical needle tip, while contact pressure of the US probe on soft tissue can displace the vessel from its initially estimated position. This study presents a sequential error-compensation method that addresses residual positioning errors before needle insertion, followed by US-based vessel-arrival detection and bounded stopping during insertion. Monocular NIR imaging is used to determine the vessel centerline and planar target on the skin surface, while US imaging provides the corresponding vessel depth coordinate for three-dimensional target localization. Probe-induced vessel displacement is incorporated into the insertion geometry to determine the required needle angle and insertion length. After insertion-path planning, the physical needle tip is redetected in the NIR image and realigned with the planar vessel target. The final insertion angle is then established and needle advancement is performed using the independent linear insertion axis. By compensating these error sources prior to penetration, the subsequent insertion stage is simplified to linear needle advancement without continuous high-DOF steering. During insertion, US-based vessel-arrival detection is combined with an independent maximum insertion-length constraint to provide bounded stopping. In phantom experiments, NIR-based needle-tip alignment increased the pre-insertion alignment success rate from 14.0% to 94.0%, while probe-induced vessel displacement compensation increased insertion success from 58.0% to 98.0%. The complete autonomous procedure achieved a 96.7% success rate. These results demonstrate that sequential compensation of probe-induced vessel displacement and physical needle-tip misalignment enables accurate and repeatable robotic venipuncture using a comparatively simple insertion architecture without continuous multi-DOF needle steering.
Open AccessRobotic Venipuncture with Sequential Needle-Tip Realignment and Probe-Induced Vessel Displacement Compensation
Robotic venipuncture systems can accurately localize vascular targets using near-infrared (NIR) and ultrasound (US) imaging. However, image-based localization does not guarantee accurate physical needle placement. Residual errors arising from sensor-to-robot registration, mechanical assembly, and needle mounting can cause misalignment of the physical needle tip, while contact pressure of the US probe on soft tissue can displace the vessel from its initially estimated position. This study presents a sequential error-compensation method that addresses residual positioning errors before needle insertion, followed by US-based vessel-arrival detection and bounded stopping during insertion. Monocular NIR imaging is used to determine the vessel centerline and planar target on the skin surface, while US imaging provides the corresponding vessel depth coordinate for three-dimensional target localization. Probe-induced vessel displacement is incorporated into the insertion geometry to determine the required needle angle and insertion length. After insertion-path planning, the physical needle tip is redetected in the NIR image and realigned with the planar vessel target. The final insertion angle is then established and needle advancement is performed using the independent linear insertion axis. By compensating these error sources prior to penetration, the subsequent insertion stage is simplified to linear needle advancement without continuous high-DOF steering. During insertion, US-based vessel-arrival detection is combined with an independent maximum insertion-length constraint to provide bounded stopping. In phantom experiments, NIR-based needle-tip alignment increased the pre-insertion alignment success rate from 14.0% to 94.0%, while probe-induced vessel displacement compensation increased insertion success from 58.0% to 98.0%. The complete autonomous procedure achieved a 96.7% success rate. These results demonstrate that sequential compensation of probe-induced vessel displacement and physical needle-tip misalignment enables accurate and repeatable robotic venipuncture using a comparatively simple insertion architecture without continuous multi-DOF needle steering.
- Open Access
Characterization and Validation of Lane-Change Precursors Based on Vehicle Kinematic States for Proactive Safety in Autonomous Driving
Lane changes (LCs) and cut-ins can increase collision risk and reduce an ego vehicle’s response time. Existing intention and trajectory prediction studies provide limited explanation of how preceding kinematic changes develop relative to normal lane keeping (LK). This study defines a lane-change precursor as a state in which kinematic deviations that are not readily accounted for by normal LK under comparable driving conditions persistently develop and strengthen. Two complementary indices quantify the rarity of cumulative directional lateral motion, evaluated in both lateral directions, and the departure of the joint lateral velocity, lateral acceleration, heading, and yaw-rate state from normal LK. Application to naturalistic trajectories from Next Generation Simulation (NGSIM) and the highD highway trajectory dataset showed increasing differences between lane-changing and normal LK vehicles toward lane transition. Multivariate state discrimination increased toward lane transition in NGSIM, whereas clear separation was observed from the beginning of the analysis window in highD. Precursors were also observed before individual lane transitions, with the two indices showing different detection and false-positive characteristics. Linking precursor information to logistic regression and long short-term memory outputs improved prediction precision and suppressed false positives during normal LK by requiring subsequent confirmation after an observed precursor. Cumulative motion and multivariate state deviation provide complementary kinematic and statistical information for interpreting and confirming maneuver predictions through observed vehicle motion. This information improves prediction reliability and can support future interaction risk assessment.
Open AccessCharacterization and Validation of Lane-Change Precursors Based on Vehicle Kinematic States for Proactive Safety in Autonomous Driving
Lane changes (LCs) and cut-ins can increase collision risk and reduce an ego vehicle’s response time. Existing intention and trajectory prediction studies provide limited explanation of how preceding kinematic changes develop relative to normal lane keeping (LK). This study defines a lane-change precursor as a state in which kinematic deviations that are not readily accounted for by normal LK under comparable driving conditions persistently develop and strengthen. Two complementary indices quantify the rarity of cumulative directional lateral motion, evaluated in both lateral directions, and the departure of the joint lateral velocity, lateral acceleration, heading, and yaw-rate state from normal LK. Application to naturalistic trajectories from Next Generation Simulation (NGSIM) and the highD highway trajectory dataset showed increasing differences between lane-changing and normal LK vehicles toward lane transition. Multivariate state discrimination increased toward lane transition in NGSIM, whereas clear separation was observed from the beginning of the analysis window in highD. Precursors were also observed before individual lane transitions, with the two indices showing different detection and false-positive characteristics. Linking precursor information to logistic regression and long short-term memory outputs improved prediction precision and suppressed false positives during normal LK by requiring subsequent confirmation after an observed precursor. Cumulative motion and multivariate state deviation provide complementary kinematic and statistical information for interpreting and confirming maneuver predictions through observed vehicle motion. This information improves prediction reliability and can support future interaction risk assessment.
- 15 August 2026
- Published by Springer Nature
- p. 389-396
Reinforcement Learning with Merged Motor Learning Theory for Personalized Upper-Limb Robot Rehabilitation
- 15 August 2026
- Published by Springer Nature
- p. 389-396
Reinforcement Learning with Merged Motor Learning Theory for Personalized Upper-Limb Robot Rehabilitation
- Open Access
Development of a Hand-Fan-Shaped Arm and a Model Predictive Controller for Leg Crossing, Walking, and One-Legged Balancing of a Wheeled-Bipedal Jumping Robot
Bipedal walking robots are advancing research by performing challenging human-like movements in complex environments. Particularly, wheeled-bipedal robots are used in many indoor environments by overcoming the speed and maneuverability limitations of bipedal walking robots without wheels. However, when both wheels lose contact with the ground, maintaining lateral balance becomes challenging, and there is an increased risk of toppling over. Furthermore, utilizing robotic arms similar to human arms, in addition to wheel-based balance, could enable more precise and stable control. In this paper, we develop a wheeled-bipedal robot that is able to jump and drive while also being able to cross its legs and balance on one leg (the OLEBOT). The OLEBOT is designed with a hand-fan-shaped end-effector capable of generating compensatory torque. By tilting the hand-fan-shaped end-effector in the opposite direction, OLEBOT achieves pitch control and single-leg balance. In jumping scenario, it imitates the arm movements of a person performing stationary high jumps, while utilizing a cam-based leg joint system to boost jump height. In addition, this paper develops a control architecture based on model predictive control (MPC) to ensure stable posture in driving, jumping, and one-legged balancing scenarios for OLEBOT. Finally, the experimental results demonstrate that OLEBOT is capable of maintaining a stable posture using a wheeled-bipedal system and achieving balance in a one-legged stance.
Open AccessDevelopment of a Hand-Fan-Shaped Arm and a Model Predictive Controller for Leg Crossing, Walking, and One-Legged Balancing of a Wheeled-Bipedal Jumping Robot
Bipedal walking robots are advancing research by performing challenging human-like movements in complex environments. Particularly, wheeled-bipedal robots are used in many indoor environments by overcoming the speed and maneuverability limitations of bipedal walking robots without wheels. However, when both wheels lose contact with the ground, maintaining lateral balance becomes challenging, and there is an increased risk of toppling over. Furthermore, utilizing robotic arms similar to human arms, in addition to wheel-based balance, could enable more precise and stable control. In this paper, we develop a wheeled-bipedal robot that is able to jump and drive while also being able to cross its legs and balance on one leg (the OLEBOT). The OLEBOT is designed with a hand-fan-shaped end-effector capable of generating compensatory torque. By tilting the hand-fan-shaped end-effector in the opposite direction, OLEBOT achieves pitch control and single-leg balance. In jumping scenario, it imitates the arm movements of a person performing stationary high jumps, while utilizing a cam-based leg joint system to boost jump height. In addition, this paper develops a control architecture based on model predictive control (MPC) to ensure stable posture in driving, jumping, and one-legged balancing scenarios for OLEBOT. Finally, the experimental results demonstrate that OLEBOT is capable of maintaining a stable posture using a wheeled-bipedal system and achieving balance in a one-legged stance.
- Open Access
- 24 August 2023
- Published by Wiley
Design and development of robotic system for precise vascular access and autonomous veinpuncture
The medical robot systems have the effect of reducing the work load and preventing accidents by supporting task that are difficult for inexperienced medical practitioners. Recently, research on automated blood collection and injection robotic system has been increasing, but work is still necessary such as replacing needle tips, setting tourniquet and fixing the patient's arm. In this letter, we propose an intelligent intravenous injection robot without having to see the medical workers face-to-face. We design a revolving system for automatic needle replacement and an arm holder for vessel fixation. Finally, we experiment positioning the needle at the target point by position control based on mathematical modeling and velocity kinematics.
- 24 August 2023
- Published by Wiley
Open AccessDesign and development of robotic system for precise vascular access and autonomous veinpuncture
The medical robot systems have the effect of reducing the work load and preventing accidents by supporting task that are difficult for inexperienced medical practitioners. Recently, research on automated blood collection and injection robotic system has been increasing, but work is still necessary such as replacing needle tips, setting tourniquet and fixing the patient's arm. In this letter, we propose an intelligent intravenous injection robot without having to see the medical workers face-to-face. We design a revolving system for automatic needle replacement and an arm holder for vessel fixation. Finally, we experiment positioning the needle at the target point by position control based on mathematical modeling and velocity kinematics.