YLYan-Sheng Li

Yan-Sheng Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yan-Sheng Li has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of the Galvanostatic Charging Current Diagnostics for the In Situ Characterization of Aged MEAs in PEMFCs

    by Yan-Sheng Li, Leonardo I. Astudillo, Markus R. Pietsch, Ana Marija Damjanović, Hubert A. Gasteiger

    Unlike in the case of single-cell proton exchange membrane fuel cells (PEMFCs), implementing voltage-controlled in situ diagnostics in PEMFC stack tests is challenging, as the single cell voltage cannot be controlled precisely. Consequently, in PEMFC stacks, current-controlled methods must be used. Here we evaluate the so-called charging current (CC) diagnostics for its suitability to quantify the electrochemically active surface area (ECSA) of a platinum-catalyzed electrode of a membrane electrode assembly (MEA) as well as the H 2 -crossover ( i H 2 − x , memb ) and the ohmic-shorting currents ( i short , memb ) of MEAs. As the here proposed analysis method enables an independent quantification of both i H 2 − x , memb and i short , memb , reliable ECSA values can be obtained not only for pristine MEAs but also for severely aged MEAs that exhibit low electrode roughness factors ( rf ) and significant H 2 -crossover and shorting currents. This is validated using model MEAs with very low rf values and/or high H 2 -crossover/shorting currents, characteristic for MEAs after accelerated stress tests (ASTs). The CC diagnostics was also applied to an automotive-scale short-stack (manufactured and tested at EKPO Fuel Cell Technologies) after ∼8000 h of a load-cycling AST. Finally, a brief guideline on how to conduct the CC diagnostics and its limitations for PEMFC stacks is presented.


  • Open Access

    Semi-Analytical Methodology to Correct Polarization Curve to Measure Tafel Slope for an Electronic Resistance Laden Catalyst Layer

    by Yadul Sethi, Yan-Sheng Li, Bharatkumar Suthar

    The polarization curve of a fuel cell shows the relationship between operating current and cell voltage. The cell voltage is lower than the equilibrium voltage due to several losses within the system. For a proton exchange membrane fuel cell (PEMFC), such losses typically arise from proton transport losses in the membrane, transport and kinetic losses in the catalyst layers, electronic transport losses in the cell components like flow-fields and the gas diffusion layers, and mass transport losses. For a mass-transport-free PEMFC operation, a previously established method corrects the polarization curve to obtain the Tafel slope of the oxygen reduction reaction for a catalyst layer without electronic transport resistance (e.g., Pt/C catalyst layer). This work builds upon that approach, extending the Tafel slope estimation to systems where both protonic and electronic transport resistances of the cathode catalyst layer are significant (e.g., platinum-group-metal-free catalysts).


  • Tafel Slope Estimation of Electronic Resistance Laden Catalyst Layer in PEMFC Using Polarization Curve Correction Methodology

    by Yadul Sethi, Yan-Sheng Li, BharatKumar Suthar

    The higher cost of PEMFC systems proves to be a major bottleneck in their adoption. Platinum being a costly material (used as a catalyst in PEMFC) contributes significantly (42%) to the overall cost of the PEMFC stack.1 The majority of the Platinum catalyst is loaded on the cathode side due to the slow nature of the oxygen reduction reaction (10-8 A/cm2 for ORR). Hence, alternative options for the cathode catalysts are being persued as a potential alternative for platinum metal group-free (PGM-free) catalyst to improve the economics of such systems.2 The sluggish kinetics of PGM-free catalysts requires much thicker CCL (compared to the Pt catalyst) to have comparable fuel cell performance at low currents.3 Thicker CCLs will lead to poorer protonic and electronic conduction. Voltage breakdown analysis from the polarization curve (Cell voltage vs Current density) is quite common in literature and is used to gather selective insights into the working of PEMFC. Work by Neyerlin et al. mathematically quantified the effect of proton conduction on the polarization curve.4 In their work, they also proposed a systematic correction methodology to retrieve the Tafel Slope by correcting the polarization curve for proton conduction and other ohmic resistances (membrane and external resistances). It is to be noted that the correction approach presented by Neyerlin et al. works well for systems with neglible electronic resistance (since it was designed for Platinum based CCLs which are thin and highly electronically conducting). However, for PGM-free catalysts which are thicker and poorer electronic conductors than Pt-based CCLs, contribution from both electronic and protonic conduction will affect the polarization curve. We propose a method to correct the polarization curve in PEMFC for effective total transport loss (both electronic and protonic) to get back the Tafel slope of the oxygen reduction reaction on the cathode side. Further, we demonstrate the approach for two different CCLs made with commercially available catalysts named PMF and in-house developed catalysts named HM (presented in Li et al)5. Note that this work assumes that the mass transport losses are not present (which is reasonable assumption in H2/O2 system) and assumes that gas cross-over effects (due to the crossing of gases through the membrane to the other side of the PEMFC) are not current dependent during fuel cell operations. Figure 1 shows the correction steps for hypothetical data generated from bvp-5C simulations (for an electronic resistance laden catalyst layer) which is treated as an actual polarization curve (orange curve represented as Ecell). In this work, we develop a semi-analytical expression for effective transport loss (represented by cyan shaded in Figure 1) which can be used to correct the (corrected for membrane proton conduction and other external electronic resistance referred to as Rmem+ext) to obtain a curve which, when fitted with the Tafel kinetics equation gives the value the Tafel slope of that CCL. References S. T. Thompson et al., Solid State Ion., 319, 68–76 (2018). Lefèvre Michel, Proietti Eric, Jaouen Frédéric, and Dodelet Jean-Pol, Science (1979), 324, 67–71 (2009). F. Jaouen et al., Johnson Matthey Technology Review, 62, 231–255 (2018). K. C. Neyerlin, W. Gu, J. Jorne, A. Clark, and H. A. Gasteiger, J. Electrochem. Soc., 154, B279 (2007). Y.-S. Li, D. Menga, H. A. Gasteiger, and B. Suthar, J. Electrochem. Soc., 170, 094503 (2023). Figure 1


  • Open Access

    On the Stability of an Atomically‐Dispersed Fe−N−C ORR Catalyst: An In Situ XAS Study in a PEMFC

    by Davide Menga, Yan‐Sheng Li, Ana Marija Damjanović, Olivier Proux, Friedrich E. Wagner, Tim‐Patrick Fellinger, Hubert A. Gasteiger, Michele Piana

    The stability of Fe−N−C oxygen reduction reaction (ORR) electrocatalysts has been considered a primary challenge for their practical application in proton exchange membrane fuel cells (PEMFCs). While several studies have attempted to reveal the possible degradation mechanism of Fe−N−C ORR catalysts, there are few research results reporting on their stability as well as the possible Fe species formed under different voltages in real PEMFC operation. In this work, we employ in‐situ X‐ray absorption near‐edge structure (XANES) to monitor the active‐site degradation byproducts of an atomically dispersed Fe−N−C ORR catalyst under a H2/O2‐operating PEMFC at 90 % relative humidity and 80 °C. For this, stability tests were carried out at two constant cell voltages, namely 0.4 and at 0.8 V. Even though the ORR activity of the Fe−N−C catalyst decreased significantly and was almost identical at the end of the tests for the two voltages employed, the analysis of the XANES recorded under H2/N2 configuration at 0.6 and 0.9 V within the stability test suggests that two different degradation mechanisms occur. They are demetalation of iron cations followed by their precipitation into Fe oxides upon operation at 0.8 V, versus a chemical carbon oxidation close to the active sites, likely triggered by reactive oxygen species (ROS) originated from the H2O2 formation, during the operation at 0.4 V.


  • Effect of the Solvent Composition in Catalyst Inks on Viscosity, Catalyst Layer Morphology, and PEMFC Performance

    by Markus Achim Schilling, Yan-Sheng Li, Hubert Andreas Gasteiger

    The solvent composition in a catalyst ink is a key parameter in fabricating cathode catalyst layers (CCLs) to reach high-performance proton exchange membrane fuel cells (PEMFCs). In general, an optimized solvent composition in a catalyst ink (e.g., the H2O-to-alcohol ratio) can yield reasonably uniform and thin ionomer structures covering the catalyst surface, leading to better proton and oxygen transport resistances of the CCLs.1,2 While the impact of solvent composition on the morphology of ionomer or catalyst in both solvent dispersion and CCLs was widely investigated, those results could vary significantly and remain inconclusive in between different studies.3 This is likely due to complex interactions between the solvent system, the ionomer, and the catalyst, and additional experimental parameters (e.g., the solvent composition in the ionomer stock dispersion, or the ink mixing method) that were not controlled. Minor changes in the fabrication process can alter the final morphology of the components in a CCL and thus vary its PEMFC performance.4 To the best of our knowledge, there are only a few systematic studies correlating the effect of the solvent system on ionomer dispersions and catalyst inks to the CCL micromorphology and PEMFC performance. In this study, we systematically examined the impact of the ratio of two commonly used solvents, 1-propanol (1-PA) and H2O, on the viscosity of ionomer dispersions (without catalysts), on the viscosity of catalyst inks (using Pt supported on a Vulcan and a Ketjenblack carbon support), on the crack formation in CCLs, and on the single-cell PEMFC performance (using 5 cm2 active area single-cell testing under differential-flow conditions). The occurrence of cracks in the CCLs was rationalized based on the rheology of the catalyst inks, the surface tension of the solvent mixtures, and the change in solvent composition during the drying process. Moreover, the influence of the ionomer stock dispersion on the viscosity of catalyst inks was investigated. This analysis shows that catalyst inks with identical compositions can have significantly different viscosities and crack formation in CCLs, depending on the ionomer stock dispersion used in the catalyst ink preparation, which highlights the importance of the processing history of the ionomer. An exemplary result is given in Figure 1, comparing the photographs of two CCLs coated on a PTFE substrate prepared with catalyst inks of identical composition. Both CCLs were fabricated with 10/90 wt% 1-PA/H2O in the catalyst inks, but different ionomer stock dispersions were used: One stock dispersion was prepared with 100 wt% H2O (Fig. 1A), and the other with a 60/40 wt% 1-PA/H2O mixture (Fig. 1B). Furthermore, we show that the shear force due to the grinding media used during the mixing of catalyst inks can trigger a gelation process of the ionomer, which strongly affects the viscosity and processibility of the catalyst ink. Finally, the impact of the solvent composition of catalyst inks on the PEMFC performance (in H2/O2 and H2/air configuration), the proton conduction resistance, and the oxygen transport resistance of the CCL were compared. Based on those results, we highlight the importance of the processing history for the fabrication of CCLs. References T. van Cleve, S. Khandavalli, A. Chowdhury, S. Medina, S. Pylypenko, M. Wang, K. L. More, N. Kariuki, D. J. Myers, A. Z. Weber et al., ACS applied materials & interfaces 2019, 11, 46953. A. Orfanidi, P. J. Rheinländer, N. Schulte, H. A. Gasteiger, J. Electrochem. Soc. 2018, 165, F1254-F1263. S. A. Berlinger, S. Garg, A. Z. Weber, Current Opinion in Electrochemistry 2021, 29, 100744. S. Khandavalli, J. H. Park, N. N. Kariuki, D. J. Myers, J. J. Stickel, K. Hurst, K. C. Neyerlin, M. Ulsh, S. A. Mauger, ACS applied materials & interfaces 2018, 10, 43610. Acknowledgment This work has been supported by the Fuel Cells and Hydrogen 2 Joint Undertaking under grant agreement No. 826097 (GAIA). This Joint Undertaking receives support from the European Union’s Horizon 2020 research and innovation program, Hydrogen Europe, and Hydrogen Europe Research. Figure 1

  • Open Access

    ORR Activity and Voltage-Cycling Stability of a Carbon-Supported PtxY Alloy Catalyst Evaluated in a PEM Fuel Cell

    by Paulette A. Loichet Torres, Yan-Sheng Li, Corbinian Grön, Timon Lazaridis, Philipp Watermeyer, Ningyan Cheng, Christian H. Liebscher, Hubert A. Gasteiger

    Platinum-yttrium alloys (PtxY) are suggested to have superior oxygen reduction reaction (ORR) activity and long-term stability in proton exchange membrane fuel cells (PEMFCs). However, the actual ORR activity and stability of a PtxY catalyst with a high electrochemically active surface area (ECSA) in a PEMFC remains uncertain. Here, a Ketjen black (KB) carbon supported PtxY/KB catalyst with a high ECSA (∼60 m2/g) was synthesized using a carbon nitride precursor. Based on elemental analysis, XRD, electron microscopy, and a mass-balance based model, it was shown that the acid-leached PtxY nanoparticles of the catalyst consist of a ∼0.7 nm thick Pt-shell and a Pt3Y core. Rotating disk electrode (RDE) and 5 cm2 single-cell PEMFC measurements indicated that the ORR activity of the acid-leached PtxY/KB catalyst is similar to an analogously synthesized Pt/KB reference catalyst with the same ECSA. Voltage-cycling accelerated stress tests (ASTs) between 0.6−1.0 V (in H2/N2 at 80 °C/95% RH) in 5 cm2 single-cells showed that the ORR activity and durability of the PtxY/KB catalyst is similar to that of the Pt/KB reference catalyst. Thus, the high durability of Pt-rare Earth alloys that has been claimed on the basis of RDE measurements is not observed in actual PEMFCs.


  • Open Access

    Design of PGM-Free Cathode Catalyst Layers for PEMFC Applications: The Impact of Electronic Conductivity

    by Yan-Sheng Li, Davide Menga, Hubert A. Gasteiger, Bharatkumar Suthar

    The impact of the electronic resistance of platinum-group-metal-free cathode catalyst layers (PGM-free CCLs) for proton-exchange-membrane fuel cells (PEMFCs) was systematically investigated. Here we selected two different PGM-free catalysts (having high and low electronic conductivity) and integrated them into CCLs without and with conductive carbon fiber additives. To investigate the impact of the electronic resistivity ( ρ e − ) of PGM-free catalysts and CCLs, their through-plane ρ e − values were quantified by an in situ electrochemical impedance spectroscopy (EIS) approach based on a one-dimensional transmission line model. The results indicate that the electronic conductivity of PGM-free CCLs can be increased by adding carbon additive, resulting in a significant improvement of the fuel cell performance (by ∼60 mV at 1 A cm−2 in H2/O2 configuration). Ex situ four-point probe measurements of the in-plane ρ e − values of some of the CCLs were found to differ vastly from the through-plane ρ e − values. This difference is attributed to the anisotropic morphology of the CCLs, caused by preferential fiber orientation and/or cracks in the CCLs. In the end, we suggest guidelines for the design and evaluation of PGM-free CCLs and for assessing and improving their electronic resistance.