Sang-Ho Choi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sang-Ho Choi has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Seong-Ki Hong
Section of Industry Cooperation and Research Planning, Jeonju University, Jeonju 55069, Republic of Korea
1 shared publication - Su-Gwang Jeong
Department of Architectural Engineering, Soongsil University, Seoul 06978, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 25 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (17) , 9647
Building Energy Savings by Developing Complex Smart Windows and Their Controllers
The interest in zero-energy buildings has increased in Korea recently. Following the significant increases in cooling and lighting energy consumption in offices, various studies have been conducted to implement energy-saving measures. The purpose of this study is to reduce lighting and cooling energy consumption in the summer through the dimming control of a complex smart window system. To achieve this, the optimal dimming control algorithm has been derived and applied in simulations to analyze the energy consumption for lighting and cooling. A smart window incorporates suspended particle display glass that actively responds to changes in indoor and outdoor environments and controls light transmittance. It also includes a light-guiding glass that can actively control solar reflectance. Simulations of office buildings were conducted to develop optimal control algorithms and controllers based on solar radiation. Subsequently, we installed this complex smart window in a test room along with the developed control algorithm and controller, which responded to the amount of insolation and time. To ensure the accuracy of the experiment, we constructed separate test and reference rooms. The experimental results obtained under the same conditions showed a reduction of approximately 36.9% in cooling energy consumption in the test room compared with the reference room and a 54.5% reduction in lighting energy consumption. Furthermore, based on additional simulations and experiments, we confirmed that the application of complex smart window systems in office buildings could reduce considerably the energy consumption for cooling and lighting.
- 25 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (17) , 9647
Open AccessBuilding Energy Savings by Developing Complex Smart Windows and Their Controllers
The interest in zero-energy buildings has increased in Korea recently. Following the significant increases in cooling and lighting energy consumption in offices, various studies have been conducted to implement energy-saving measures. The purpose of this study is to reduce lighting and cooling energy consumption in the summer through the dimming control of a complex smart window system. To achieve this, the optimal dimming control algorithm has been derived and applied in simulations to analyze the energy consumption for lighting and cooling. A smart window incorporates suspended particle display glass that actively responds to changes in indoor and outdoor environments and controls light transmittance. It also includes a light-guiding glass that can actively control solar reflectance. Simulations of office buildings were conducted to develop optimal control algorithms and controllers based on solar radiation. Subsequently, we installed this complex smart window in a test room along with the developed control algorithm and controller, which responded to the amount of insolation and time. To ensure the accuracy of the experiment, we constructed separate test and reference rooms. The experimental results obtained under the same conditions showed a reduction of approximately 36.9% in cooling energy consumption in the test room compared with the reference room and a 54.5% reduction in lighting energy consumption. Furthermore, based on additional simulations and experiments, we confirmed that the application of complex smart window systems in office buildings could reduce considerably the energy consumption for cooling and lighting.