Adrian Rogers
Research Subjects
Adrian Rogers has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Elizabeth N. Clare Mills
Division of Immunology, Immunity to Infection and Respiratory Medicine, School of Biological Sciences, Manchester Institute of Biotechnology, University of Manchester, Manchester, UK
2 shared publications Angela Simpson
Division of Immunology, Immunity to Infection and Respiratory Medicine, School of Biological Sciences, Manchester University NHS Foundation Trust
1 shared publication- Charlotte Bernhard Madsen
National Food Institute, Technical University of Denmark, Kgs. Lyngby, Denmark
1 shared publication Chiara Nitride
Department of Agricultural Sciences
1 shared publicationJoan Bartra-Tomas
Allergy Department, Hospital Clinic
1 shared publication- Johnna Perry
In Johnna’s Kitchen , 1306 Barford Dr , Liberty, MO 64068, United States
1 shared publication
Latest Publications
- Open Access
- 22 May 2025
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 73 (22) , 14099-14111
From Peptide to Protein: Development of Conversion Factors for the Quantification of Gluten Using Targeted Mass Spectrometry
Immuno- and mass spectrometry (MS) test methods have been used to ensure "gluten-free" food products contain less than 20 ppm of gluten. However, comparison of test method performance is difficult due to differences in reporting units. A set of wheat flour fractions was prepared and characterized regarding immunoglobulin E (IgE)-reactivity and protein profile, which were then used to screen a panel of gluten peptides to identify reporters suitable for use in an MS test method for gluten determination. Four peptide markers were selected and synthesized as heavy isotopically labeled versions for further evaluation. Two were derived from α-gliadin (RPQQPYPQPQPQY and QPFPQPQLPY [spanning a celiac toxic motif]), one each from γ-gliadin (GIIQPQQPAQL [spanning a celiac toxic motif and IgE epitope]), and a low-molecular-weight subunit of glutenin (VQQQIPVVQPSIL). Analysis of the wheat flour fractions was achieved with peptides RPQQPYPQPQPQY, GIIQPQQPAQL, and VQQQIPVVQPSIL. Two methods were used to derive a set of factors for converting from peptide marker to gluten protein: one based on calculation and a second on experimental analysis using either the gliadin or glutenin protein fractions. Experimentally derived conversion factors performed better when used in an MS test method to quantify gluten in a set of wheat flour samples. Peptide VQQIPVVQPSIL showed the greatest sensitivity and, when employing a glutenin fraction-based conversion factor, gave comparable results to protein levels determined using Dumas total nitrogen analysis. This peptide marker demonstrated the potential to determine gluten at a level around the 10 mg gluten/kg food product level, showing that the prototype method and approaches described have the potential to deliver a complementary method for determination of gluten in food.
- 22 May 2025
- Published by American Chemical Society (ACS) in Journal of Agricultural and Food Chemistry
- Vol. 73 (22) , 14099-14111
Open AccessFrom Peptide to Protein: Development of Conversion Factors for the Quantification of Gluten Using Targeted Mass Spectrometry
Immuno- and mass spectrometry (MS) test methods have been used to ensure "gluten-free" food products contain less than 20 ppm of gluten. However, comparison of test method performance is difficult due to differences in reporting units. A set of wheat flour fractions was prepared and characterized regarding immunoglobulin E (IgE)-reactivity and protein profile, which were then used to screen a panel of gluten peptides to identify reporters suitable for use in an MS test method for gluten determination. Four peptide markers were selected and synthesized as heavy isotopically labeled versions for further evaluation. Two were derived from α-gliadin (RPQQPYPQPQPQY and QPFPQPQLPY [spanning a celiac toxic motif]), one each from γ-gliadin (GIIQPQQPAQL [spanning a celiac toxic motif and IgE epitope]), and a low-molecular-weight subunit of glutenin (VQQQIPVVQPSIL). Analysis of the wheat flour fractions was achieved with peptides RPQQPYPQPQPQY, GIIQPQQPAQL, and VQQQIPVVQPSIL. Two methods were used to derive a set of factors for converting from peptide marker to gluten protein: one based on calculation and a second on experimental analysis using either the gliadin or glutenin protein fractions. Experimentally derived conversion factors performed better when used in an MS test method to quantify gluten in a set of wheat flour samples. Peptide VQQIPVVQPSIL showed the greatest sensitivity and, when employing a glutenin fraction-based conversion factor, gave comparable results to protein levels determined using Dumas total nitrogen analysis. This peptide marker demonstrated the potential to determine gluten at a level around the 10 mg gluten/kg food product level, showing that the prototype method and approaches described have the potential to deliver a complementary method for determination of gluten in food.
- Open Access
- 7 August 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 106 (6) , 1696-1700
Consumer-Led Investigation into Potential Issues That Arise When Testing Dairy Matrixes for Gluten With the NIMA Sensor
Background: Some consumers with celiac disease use personal, point-of-use gluten detection devices to test food. False-positive results may occur due to sampling, matrix effects, and sensor issues. Objective: The purpose of the present study was to determine if the positive gluten results some users were obtaining when testing cream cheese and materials of similar consistency were false positives and, if so, what might be causing them to occur. Methods: Cream cheese, soft cheese, and yogurt were tested for gluten using the Ridascreen Gliadin R7001 sandwich R5 ELISA and the Ridascreen Gliadin R7021 competitive R5 ELISA. Two test portions were taken, extracted, and tested from each homogenized material. Materials were also analyzed for gluten using a NIMA sensor, a personal, point-of-use gluten detection device. Multiple test portion weights were tested beginning at 0.13 to 0.17 g (the ideal weight of the test portion according to the NIMA sensor development team). Results: Using the sandwich R5 ELISA and the competitive R5 ELISA, all materials tested below the lower LOD for gluten. Using a NIMA sensor, as the weight of the test portion tested increased, sensor results went from no gluten found, to gluten found, to no test result. Conclusion: The gluten found results using the NIMA sensor are likely false positives that appear to correspond with the weight and volume of the material tested, as well as the viscosity. There is also an apparent disconnect between the gluten found result reported by the sensor and an interpretation of the lateral flow device (LFD) strip result when assessed by eye which should also be taken into account. Ideally, NIMA sensor users should be advised on the weight amount of material to analyze and test portions should be weighed before being used with the NIMA sensor. However, this is not a practical solution when testing in many environments, including restaurants. Highlights: Slight variations in weight and volume of test materials can result in false positive results when testing dairy matrixes for gluten using the Nima sensor.
- 7 August 2023
- Published by Oxford University Press (OUP) in Journal of AOAC INTERNATIONAL
- Vol. 106 (6) , 1696-1700
Open AccessConsumer-Led Investigation into Potential Issues That Arise When Testing Dairy Matrixes for Gluten With the NIMA Sensor
Background: Some consumers with celiac disease use personal, point-of-use gluten detection devices to test food. False-positive results may occur due to sampling, matrix effects, and sensor issues. Objective: The purpose of the present study was to determine if the positive gluten results some users were obtaining when testing cream cheese and materials of similar consistency were false positives and, if so, what might be causing them to occur. Methods: Cream cheese, soft cheese, and yogurt were tested for gluten using the Ridascreen Gliadin R7001 sandwich R5 ELISA and the Ridascreen Gliadin R7021 competitive R5 ELISA. Two test portions were taken, extracted, and tested from each homogenized material. Materials were also analyzed for gluten using a NIMA sensor, a personal, point-of-use gluten detection device. Multiple test portion weights were tested beginning at 0.13 to 0.17 g (the ideal weight of the test portion according to the NIMA sensor development team). Results: Using the sandwich R5 ELISA and the competitive R5 ELISA, all materials tested below the lower LOD for gluten. Using a NIMA sensor, as the weight of the test portion tested increased, sensor results went from no gluten found, to gluten found, to no test result. Conclusion: The gluten found results using the NIMA sensor are likely false positives that appear to correspond with the weight and volume of the material tested, as well as the viscosity. There is also an apparent disconnect between the gluten found result reported by the sensor and an interpretation of the lateral flow device (LFD) strip result when assessed by eye which should also be taken into account. Ideally, NIMA sensor users should be advised on the weight amount of material to analyze and test portions should be weighed before being used with the NIMA sensor. However, this is not a practical solution when testing in many environments, including restaurants. Highlights: Slight variations in weight and volume of test materials can result in false positive results when testing dairy matrixes for gluten using the Nima sensor.
- 1 February 2011
- Published by S. Karger AG in International Archives of Allergy and Immunology
- Vol. 155 (3) , 212-224
Sensitization with 7S Globulins from Peanut, Hazelnut, Soy or Pea Induces IgE with Different Biological Activities Which Are Modified by Soy Tolerance
Background: It is not known why some foods sensitizing via the gastrointestinal tract are prevalent allergenic foods and others are not. Eating habits, processing, and the food matrix have been suggested to influence the allergenicity of a given food. Factors related to protein structure, such as stability to digestion, have also been suggested. 7S globulins from peanut, hazelnut, soy, and pea were studied to determine whether related proteins would induce a similar sensitization when removed from their ‘normal’ matrix. Methods: Brown Norway rats (soy tolerant or nontolerant) were immunized i.p. 3 times with 100 µg purified peanut, hazelnut, soy, or pea 7S without adjuvant. Sera were analyzed for specific antibodies by different ELISAs (IgG1, IgG2a, and IgE), inhibition ELISA, and rat basophilic leukemia cell assay. Results: The 4 related 7S globulins induced a response with an almost identical level of specific antibodies, but peanut 7S induced IgE of higher avidity than hazelnut and pea 7S which, again, had a higher avidity than IgE induced by soy 7S. Soy tolerance reduced the functionality of IgE without influencing antibody titers. Conclusions: Although the 4 7S globulins are structurally related allergens, they induce antibodies with different antigen-binding characteristics. Peanut 7S induces IgE of a higher avidity than hazelnut and pea 7S which, again, has a higher avidity than IgE induced by soy 7S. We also show that soy tolerance influences the function of antibodies to peanut 7S. These findings may help explain how antibodies of different clinical significances can develop in different individuals sensitized to the same allergen.
- 1 February 2011
- Published by S. Karger AG in International Archives of Allergy and Immunology
- Vol. 155 (3) , 212-224
Sensitization with 7S Globulins from Peanut, Hazelnut, Soy or Pea Induces IgE with Different Biological Activities Which Are Modified by Soy Tolerance
Background: It is not known why some foods sensitizing via the gastrointestinal tract are prevalent allergenic foods and others are not. Eating habits, processing, and the food matrix have been suggested to influence the allergenicity of a given food. Factors related to protein structure, such as stability to digestion, have also been suggested. 7S globulins from peanut, hazelnut, soy, and pea were studied to determine whether related proteins would induce a similar sensitization when removed from their ‘normal’ matrix. Methods: Brown Norway rats (soy tolerant or nontolerant) were immunized i.p. 3 times with 100 µg purified peanut, hazelnut, soy, or pea 7S without adjuvant. Sera were analyzed for specific antibodies by different ELISAs (IgG1, IgG2a, and IgE), inhibition ELISA, and rat basophilic leukemia cell assay. Results: The 4 related 7S globulins induced a response with an almost identical level of specific antibodies, but peanut 7S induced IgE of higher avidity than hazelnut and pea 7S which, again, had a higher avidity than IgE induced by soy 7S. Soy tolerance reduced the functionality of IgE without influencing antibody titers. Conclusions: Although the 4 7S globulins are structurally related allergens, they induce antibodies with different antigen-binding characteristics. Peanut 7S induces IgE of a higher avidity than hazelnut and pea 7S which, again, has a higher avidity than IgE induced by soy 7S. We also show that soy tolerance influences the function of antibodies to peanut 7S. These findings may help explain how antibodies of different clinical significances can develop in different individuals sensitized to the same allergen.
- 1 September 1990
- Published by Elsevier in Aquatic Toxicology
- Vol. 17 (3) , 213-230
The survival of early life stages of brown trout (Salmo trutta L.) in relation to aluminium speciation in upland Welsh streams
- 1 September 1990
- Published by Elsevier in Aquatic Toxicology
- Vol. 17 (3) , 213-230
The survival of early life stages of brown trout (Salmo trutta L.) in relation to aluminium speciation in upland Welsh streams