Chunxu Qin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chunxu Qin has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Changjiang Ding
College of Electric Power, Inner Mongolia University of Technology, Hohhot 010080, China
4 shared publications - Liqiang Liu
College of Electric Power, Inner Mongolia University of Technology, Hohhot 010080, China
4 shared publications - Zhiqing Song
College of Electric Power, Inner Mongolia University of Technology, Hohhot, China
3 shared publications Chuanqiang Che
Inner Mongolia Electric Power Research Institute, Hohhot 010051, China
2 shared publications- Chuanqiang Che
Inner Mongolia Electric Power Research Institute, Hohhot 010051, China
2 shared publications Hao Chen
College of Science, Inner Mongolia University of Technology, Hohhot 010051, China
2 shared publications
Latest Publications
- Open Access
Surrogate Modeling of the Electric Field in the End-Winding Region of Pumped-Storage Generator Stators Based on Deep Neural Networks
The end-winding insulation structure of stator windings in pumped-storage generator units is complex, with pronounced electric field concentration under out-of-phase conditions, making them critical concerns in insulation design and condition-based maintenance. Although the finite element method (FEM) offers reliable accuracy, the strong nonlinearity of the anti-corona layer results in a computation time exceeding 104 seconds per single solution, rendering it impractical for parameter optimization and rapid on-site assessment. This paper proposes a fast prediction method for end-region potential distribution based on a deep neural network (DNN). Taking a 334 MW unit as the research object, a three-dimensional electroquasistatic finite element model with six stator coils is established and validated through power-frequency withstand voltage and ultraviolet imaging experiments. Training samples are generated via design of experiments (DoE), and a multilayer DNN surrogate model with a 7-dimensional input (comprising 3D spatial coordinates and four physical parameters) and a 1-dimensional output is constructed to directly reconstruct the spatial potential field at the end region. The results demonstrate that the surrogate model achieves a maximum relative error of less than 2% along the entire path compared with the high-fidelity FEM solutions, with a single prediction time of approximately 38 s—representing a speedup factor of approximately 272—while also exhibiting good generalization capability. This method provides a feasible technical approach for rapid reconstruction of end-region field distribution and optimization of insulation structures.
Open AccessSurrogate Modeling of the Electric Field in the End-Winding Region of Pumped-Storage Generator Stators Based on Deep Neural Networks
The end-winding insulation structure of stator windings in pumped-storage generator units is complex, with pronounced electric field concentration under out-of-phase conditions, making them critical concerns in insulation design and condition-based maintenance. Although the finite element method (FEM) offers reliable accuracy, the strong nonlinearity of the anti-corona layer results in a computation time exceeding 104 seconds per single solution, rendering it impractical for parameter optimization and rapid on-site assessment. This paper proposes a fast prediction method for end-region potential distribution based on a deep neural network (DNN). Taking a 334 MW unit as the research object, a three-dimensional electroquasistatic finite element model with six stator coils is established and validated through power-frequency withstand voltage and ultraviolet imaging experiments. Training samples are generated via design of experiments (DoE), and a multilayer DNN surrogate model with a 7-dimensional input (comprising 3D spatial coordinates and four physical parameters) and a 1-dimensional output is constructed to directly reconstruct the spatial potential field at the end region. The results demonstrate that the surrogate model achieves a maximum relative error of less than 2% along the entire path compared with the high-fidelity FEM solutions, with a single prediction time of approximately 38 s—representing a speedup factor of approximately 272—while also exhibiting good generalization capability. This method provides a feasible technical approach for rapid reconstruction of end-region field distribution and optimization of insulation structures.
- Open Access
Study on Thermal–Fluid Coupling Simulation of GIS Disconnect Switch Considering External Environmental Factors
To address the difficulty of directly measuring the internal conductor temperature and the complex influence of external environmental factors on gas-insulated switchgear (GIS), a three-dimensional thermal–fluid multiphysics coupling model was developed for a 110 kV three-phase common-enclosure GIS disconnect switch. The model incorporates contact resistance heating, natural convection of SF6 gas, wind speed, and solar radiation. The effects of contact resistance and environmental factors on the temperature field distribution were systematically investigated. The results show that an increase in contact resistance significantly raises the conductor temperature, while higher wind speeds effectively reduce the temperature rise of the equipment. Solar radiation substantially increases the enclosure temperature, whereas ambient temperature has little influence on temperature rise. Based on the enclosure temperature rise, a conductor temperature-rise prediction model and a multi-factor correction model were established. Validation results indicate that all models achieved coefficients of determination greater than 0.98, with prediction errors controlled within ±2 °C. The proposed method enables the accurate prediction of conductor temperature under complex environmental conditions and provides technical support for condition monitoring and overheating fault diagnosis of GIS equipment.
Open AccessStudy on Thermal–Fluid Coupling Simulation of GIS Disconnect Switch Considering External Environmental Factors
To address the difficulty of directly measuring the internal conductor temperature and the complex influence of external environmental factors on gas-insulated switchgear (GIS), a three-dimensional thermal–fluid multiphysics coupling model was developed for a 110 kV three-phase common-enclosure GIS disconnect switch. The model incorporates contact resistance heating, natural convection of SF6 gas, wind speed, and solar radiation. The effects of contact resistance and environmental factors on the temperature field distribution were systematically investigated. The results show that an increase in contact resistance significantly raises the conductor temperature, while higher wind speeds effectively reduce the temperature rise of the equipment. Solar radiation substantially increases the enclosure temperature, whereas ambient temperature has little influence on temperature rise. Based on the enclosure temperature rise, a conductor temperature-rise prediction model and a multi-factor correction model were established. Validation results indicate that all models achieved coefficients of determination greater than 0.98, with prediction errors controlled within ±2 °C. The proposed method enables the accurate prediction of conductor temperature under complex environmental conditions and provides technical support for condition monitoring and overheating fault diagnosis of GIS equipment.
- Open Access
- 28 May 2026
- Published by MDPI AG in Antioxidants
- Vol. 15 (6) , 681
Cold Plasma Treatment Enhances Drought Tolerance of Alfalfa (Medicago sativa L.) Seeds by Modulating Physiological Responses and Transcriptomic Profiles
Drought stress is a major limiting factor for alfalfa (Medicago sativa L.) production in arid and semi-arid regions. Cold plasma treatment has emerged as a promising physical technology for improving seed germination and stress tolerance, but its underlying mechanisms remain poorly understood. In this study, alfalfa seeds were treated with cold plasma (plasma discharge voltage: 0, 5, 10, 15 kV) for 5 min and exposed to PEG 6000 stress at 0, 5, 10, and 15%. Results showed that cold plasma treatment significantly alleviated the inhibitory effects of drought stress on seed germination, with the Plasma-15 kV treatment exhibiting the highest germination potential and germination rate compared to the control (p < 0.05). Plasma treatment enhanced the activities of superoxide dismutase (SOD), peroxidase (POD), and catalase (CAT), while reducing malondialdehyde (MDA) content (p < 0.05), indicating mitigated oxidative damage under drought conditions. Transcriptomic analysis revealed that cold plasma regulated the expression of genes involved in the MAPK signaling pathway and other drought-responsive pathways, leading to metabolic reallocation (Q < 0.05) and enhanced drought tolerance. In conclusion, 5 min of Plasma-15 kV treatment effectively enhances drought tolerance via physiological and transcriptional regulation, providing an eco-friendly strategy for alfalfa cultivation in dry regions.
- 28 May 2026
- Published by MDPI AG in Antioxidants
- Vol. 15 (6) , 681
Open AccessCold Plasma Treatment Enhances Drought Tolerance of Alfalfa (Medicago sativa L.) Seeds by Modulating Physiological Responses and Transcriptomic Profiles
Drought stress is a major limiting factor for alfalfa (Medicago sativa L.) production in arid and semi-arid regions. Cold plasma treatment has emerged as a promising physical technology for improving seed germination and stress tolerance, but its underlying mechanisms remain poorly understood. In this study, alfalfa seeds were treated with cold plasma (plasma discharge voltage: 0, 5, 10, 15 kV) for 5 min and exposed to PEG 6000 stress at 0, 5, 10, and 15%. Results showed that cold plasma treatment significantly alleviated the inhibitory effects of drought stress on seed germination, with the Plasma-15 kV treatment exhibiting the highest germination potential and germination rate compared to the control (p < 0.05). Plasma treatment enhanced the activities of superoxide dismutase (SOD), peroxidase (POD), and catalase (CAT), while reducing malondialdehyde (MDA) content (p < 0.05), indicating mitigated oxidative damage under drought conditions. Transcriptomic analysis revealed that cold plasma regulated the expression of genes involved in the MAPK signaling pathway and other drought-responsive pathways, leading to metabolic reallocation (Q < 0.05) and enhanced drought tolerance. In conclusion, 5 min of Plasma-15 kV treatment effectively enhances drought tolerance via physiological and transcriptional regulation, providing an eco-friendly strategy for alfalfa cultivation in dry regions.
- 2 February 2026
- Published by Elsevier in Food Research International
- Vol. 230, 118540
Volatile odor characterization of electrohydrodynamically (EHD) dried garlic products based on HS-GC-IMS and HS-SPME-GC-MS
- 2 February 2026
- Published by Elsevier in Food Research International
- Vol. 230, 118540
Volatile odor characterization of electrohydrodynamically (EHD) dried garlic products based on HS-GC-IMS and HS-SPME-GC-MS
- Open Access
- 6 September 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 121, 107548
Comprehensive analysis of ultrasound-assisted electrohydrodynamic technology on drying characteristics, quality attributes, and volatile profiles of yam (Dioscorea opposita)
- 6 September 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 121, 107548
Open AccessComprehensive analysis of ultrasound-assisted electrohydrodynamic technology on drying characteristics, quality attributes, and volatile profiles of yam (Dioscorea opposita)
- Open Access
- 21 February 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (5) , 468
Study on the Effects of High-Voltage Discharge Plasma Drying on the Volatile Organic Compounds and Texture Characteristics of Oat Grass
Oat grass is a high-quality forage with exceptional nutritional value and quality. Freshly harvested oat grass requires rapid drying to extend its shelf life. Currently, the primary methods for drying oat grass are natural air drying (AD) and hot air drying (HAD). However, prolonged drying times or elevated temperatures can lead to a degradation in hay quality. To address this issue, in this study, we employed a novel non-thermal drying technology—high-voltage discharge plasma drying (HVDPD)—to dry oat grass. The HVDPD device adopted a multi-needle plate electrode system, with a high-voltage power output of 50 Hz AC and a voltage set to 35 kV. The distance between the needle tip and the plate was set to 10 cm, while the spacing between the needles was adjusted only to three gradients of 2 cm, 8 cm, and 12 cm. To investigate the effects of HVDPD, HAD, and AD on the volatile compounds and textural characteristics of oat grass, in this study, we employed gas chromatography–mass spectrometry (GC-MS) for qualitative and quantitative analyses of the primary volatile components in oat hay. The texture characteristics were determined using texture profile analysis (TPA) and shear testing. A total of 103 volatile substances were detected in oat grass. We categorized them into the following: 28 types of alkanes, 17 types of alkenes, 8 types of esters, 11 types of ketones, 13 types of aldehydes, 20 types of alcohols, and 6 other classes of compounds. We found that the HVDPD group demonstrated significant advantages in enhancing the volatile flavor and palatability of oat grass. The results of the textural properties showed that the structure of oat grass treated with HVDPD was significantly softer, with the 2 cm needle-spacing group exhibiting superior quality and palatability. Overall, this research demonstrates the significant advantages of HVDPD for drying oat grass, providing an important reference for its application in the field of drying technology.
- 21 February 2025
- Published by MDPI AG in Agriculture
- Vol. 15 (5) , 468
Open AccessStudy on the Effects of High-Voltage Discharge Plasma Drying on the Volatile Organic Compounds and Texture Characteristics of Oat Grass
Oat grass is a high-quality forage with exceptional nutritional value and quality. Freshly harvested oat grass requires rapid drying to extend its shelf life. Currently, the primary methods for drying oat grass are natural air drying (AD) and hot air drying (HAD). However, prolonged drying times or elevated temperatures can lead to a degradation in hay quality. To address this issue, in this study, we employed a novel non-thermal drying technology—high-voltage discharge plasma drying (HVDPD)—to dry oat grass. The HVDPD device adopted a multi-needle plate electrode system, with a high-voltage power output of 50 Hz AC and a voltage set to 35 kV. The distance between the needle tip and the plate was set to 10 cm, while the spacing between the needles was adjusted only to three gradients of 2 cm, 8 cm, and 12 cm. To investigate the effects of HVDPD, HAD, and AD on the volatile compounds and textural characteristics of oat grass, in this study, we employed gas chromatography–mass spectrometry (GC-MS) for qualitative and quantitative analyses of the primary volatile components in oat hay. The texture characteristics were determined using texture profile analysis (TPA) and shear testing. A total of 103 volatile substances were detected in oat grass. We categorized them into the following: 28 types of alkanes, 17 types of alkenes, 8 types of esters, 11 types of ketones, 13 types of aldehydes, 20 types of alcohols, and 6 other classes of compounds. We found that the HVDPD group demonstrated significant advantages in enhancing the volatile flavor and palatability of oat grass. The results of the textural properties showed that the structure of oat grass treated with HVDPD was significantly softer, with the 2 cm needle-spacing group exhibiting superior quality and palatability. Overall, this research demonstrates the significant advantages of HVDPD for drying oat grass, providing an important reference for its application in the field of drying technology.
- Open Access
- 18 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (22) , 10655
Influence of Electrohydrodynamics on the Drying Characteristics and Volatile Components of Ginger
This article studies the electrohydrodynamic drying of ginger. In this work, drying experiments were performed in an electrohydrodynamic drying (EHD) system at various AC voltages (0 kV (control), 15 kV, 20 kV, 25 kV, and 30 kV). The drying properties and volatile components of ginger were thoroughly examined and studied using IR spectroscopy and GC–MS. The findings revealed that electrohydrodynamics significantly increased the drying rate and reduced the drying time of ginger, with a sevenfold increase in drying rate and a one-third reduction in drying time at 30 kV. The peak of the infrared spectrum of ginger remains unchanged. We found 240 volatile chemicals under different drying voltages. The primary volatile chemicals were esters and aldehydes. The ginger products dried at 30 kV had the lowest aldehyde concentration. These findings give an experimental and theoretical foundation for applying electrohydrodynamics to the subject of ginger drying.
- 18 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (22) , 10655
Open AccessInfluence of Electrohydrodynamics on the Drying Characteristics and Volatile Components of Ginger
This article studies the electrohydrodynamic drying of ginger. In this work, drying experiments were performed in an electrohydrodynamic drying (EHD) system at various AC voltages (0 kV (control), 15 kV, 20 kV, 25 kV, and 30 kV). The drying properties and volatile components of ginger were thoroughly examined and studied using IR spectroscopy and GC–MS. The findings revealed that electrohydrodynamics significantly increased the drying rate and reduced the drying time of ginger, with a sevenfold increase in drying rate and a one-third reduction in drying time at 30 kV. The peak of the infrared spectrum of ginger remains unchanged. We found 240 volatile chemicals under different drying voltages. The primary volatile chemicals were esters and aldehydes. The ginger products dried at 30 kV had the lowest aldehyde concentration. These findings give an experimental and theoretical foundation for applying electrohydrodynamics to the subject of ginger drying.
- Open Access
Partial Discharge Signal Pattern Recognition of Composite Insulation Defects in Cross-Linked Polyethylene Cables
To investigate the pattern recognition of complex defect types in XLPE (cross-linked polyethylene) cable partial discharges and analyze the effectiveness of identifying partial discharge signal patterns, this study employs the variational mode decomposition (VMD) algorithm alongside entropy theories such as power spectrum entropy, fuzzy entropy, and permutation entropy for feature extraction from partial discharge signals of composite insulation defects. The mean power spectrum entropy (PS), mean fuzzy entropy (FU), mean permutation entropy (PE), as well as the permutation entropy values of IMF2 and IMF13 (Pe) are selected as the characteristic quantities for four categories of partial discharge signals associated with composite defects. Six hundred samples are selected from the partial discharge signals of each type of compound defect, amounting to a total of 2400 samples for the four types of compound defects combined. Each sample comprises five feature values, which are compiled into a dataset. A Snake Optimization Algorithm-optimized Support Vector Machine (SO-SVM) model is designed and trained, using the extracted features from cable partial discharge datasets as case examples for recognizing cable partial discharge signals. The identification outcomes from the SO-SVM model are then compared with those from conventional learning models. The results demonstrate that for partial discharge signals of XLPE cable composite insulation defects, the SO-SVM model yields better identification results than traditional learning models. In terms of recognition accuracy, for scratch and water ingress defects, SO-SVM improves by 14.00% over BP (Back Propagation) neural networks, by 5.66% over GA-BP (Genetic Algorithm–Back Propagation), and by 12.50% over SVM (support vector machine). For defects involving metal impurities and scratches, SO-SVM improves by 13.39% over BP, 9.34% over GA-BP, and 12.56% over SVM. For defects with metal impurities and water ingress, SO-SVM shows enhancements of 13.80% over BP, 9.47% over GA-BP, and 13.97% over SVM. Lastly, for defects combining metal impurities, water ingress, and scratches, SO-SVM registers increases of 11.90% over BP, 9.59% over GA-BP, and 12.05% over SVM.
Open AccessPartial Discharge Signal Pattern Recognition of Composite Insulation Defects in Cross-Linked Polyethylene Cables
To investigate the pattern recognition of complex defect types in XLPE (cross-linked polyethylene) cable partial discharges and analyze the effectiveness of identifying partial discharge signal patterns, this study employs the variational mode decomposition (VMD) algorithm alongside entropy theories such as power spectrum entropy, fuzzy entropy, and permutation entropy for feature extraction from partial discharge signals of composite insulation defects. The mean power spectrum entropy (PS), mean fuzzy entropy (FU), mean permutation entropy (PE), as well as the permutation entropy values of IMF2 and IMF13 (Pe) are selected as the characteristic quantities for four categories of partial discharge signals associated with composite defects. Six hundred samples are selected from the partial discharge signals of each type of compound defect, amounting to a total of 2400 samples for the four types of compound defects combined. Each sample comprises five feature values, which are compiled into a dataset. A Snake Optimization Algorithm-optimized Support Vector Machine (SO-SVM) model is designed and trained, using the extracted features from cable partial discharge datasets as case examples for recognizing cable partial discharge signals. The identification outcomes from the SO-SVM model are then compared with those from conventional learning models. The results demonstrate that for partial discharge signals of XLPE cable composite insulation defects, the SO-SVM model yields better identification results than traditional learning models. In terms of recognition accuracy, for scratch and water ingress defects, SO-SVM improves by 14.00% over BP (Back Propagation) neural networks, by 5.66% over GA-BP (Genetic Algorithm–Back Propagation), and by 12.50% over SVM (support vector machine). For defects involving metal impurities and scratches, SO-SVM improves by 13.39% over BP, 9.34% over GA-BP, and 12.56% over SVM. For defects with metal impurities and water ingress, SO-SVM shows enhancements of 13.80% over BP, 9.47% over GA-BP, and 13.97% over SVM. Lastly, for defects combining metal impurities, water ingress, and scratches, SO-SVM registers increases of 11.90% over BP, 9.59% over GA-BP, and 12.05% over SVM.
- Open Access
- 26 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (17) , 9656
Study on Power Frequency Breakdown Characteristics of Nano-TiO2 Modified Transformer Oil under Severe Cold Conditions
With 45# transformer oil as the base fluid, different concentrations of TiO2 nanomodified transformer oil were prepared via the thermal oscillation method. Nanomodified transformer oil with a concentration of 0.01 g/L was selected for evaluation via the breakdown test. Then, 0.01 g/L nanomodified transformer oil and ordinary 45# transformer oil were subjected to the variable control of different moisture contents and different temperatures, and breakdown tests under different types of electrodes were performed within the temperature range of −30 °C to 30 °C. The test results showed the following: Under severe cold conditions, the improvement effect of the breakdown voltage in different temperature ranges was different. Within the temperature range of −30 °C to −10 °C, the enhancement effect could reach 13% to 15%. Within the temperature range of −10 °C to 0 °C, the enhancement effect could reach 8% to 9%. Within the temperature range of 0 °C to 30 °C, the enhancement effect could reach 18% to 21%. Compared with the test results at high water contents, the improvement in the breakdown voltage amplitude of transformer oil by nanomaterials was more obvious at low water contents. In addition, nanomaterials could reduce the dispersion of the breakdown voltage to make the breakdown voltage more stable. Lastly, COMSOL was used to simulate the polarization process of nanoparticles under a uniform electric field and the influence of the trajectory of charged particles in the oil to further analyze the mechanism of the influence of nanoparticles in oil on the breakdown voltage of the oil gap. The simulation results showed that, when the particles were accelerated by the electric field, they moved irregularly. After adding nanoparticles, the charged particles were adsorbed by the nanoparticles when passing through the nanoparticles, which reduced the migration rate of charged particles in the oil. The breakdown voltage of the oil gap increased.
- 26 August 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (17) , 9656
Open AccessStudy on Power Frequency Breakdown Characteristics of Nano-TiO2 Modified Transformer Oil under Severe Cold Conditions
With 45# transformer oil as the base fluid, different concentrations of TiO2 nanomodified transformer oil were prepared via the thermal oscillation method. Nanomodified transformer oil with a concentration of 0.01 g/L was selected for evaluation via the breakdown test. Then, 0.01 g/L nanomodified transformer oil and ordinary 45# transformer oil were subjected to the variable control of different moisture contents and different temperatures, and breakdown tests under different types of electrodes were performed within the temperature range of −30 °C to 30 °C. The test results showed the following: Under severe cold conditions, the improvement effect of the breakdown voltage in different temperature ranges was different. Within the temperature range of −30 °C to −10 °C, the enhancement effect could reach 13% to 15%. Within the temperature range of −10 °C to 0 °C, the enhancement effect could reach 8% to 9%. Within the temperature range of 0 °C to 30 °C, the enhancement effect could reach 18% to 21%. Compared with the test results at high water contents, the improvement in the breakdown voltage amplitude of transformer oil by nanomaterials was more obvious at low water contents. In addition, nanomaterials could reduce the dispersion of the breakdown voltage to make the breakdown voltage more stable. Lastly, COMSOL was used to simulate the polarization process of nanoparticles under a uniform electric field and the influence of the trajectory of charged particles in the oil to further analyze the mechanism of the influence of nanoparticles in oil on the breakdown voltage of the oil gap. The simulation results showed that, when the particles were accelerated by the electric field, they moved irregularly. After adding nanoparticles, the charged particles were adsorbed by the nanoparticles when passing through the nanoparticles, which reduced the migration rate of charged particles in the oil. The breakdown voltage of the oil gap increased.