Heejung Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Heejung Kim has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Boram Ha
Department of Radiation Oncology, Hallylm University Dongtan Sacred Heart Hospital, Hwaseong 14068, Korea
1 shared publication - Eun Seog Kim
Department of Radiation Oncology, College of Medicine, Soonchunhyang University Cheonan Hospital, Cheonan 31151, Republic of Korea
1 shared publication - Hae Jin Park
Department of Radiation Oncology, Hanyang University College of Medicine, Seoul, Korea
1 shared publication - Haeyoung Kim
Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea
1 shared publication - Hyung-Sik Lee
Department of Radiation Oncology, Dong-A University Hospital, Dong-A University School of Medicine, Busan 49201, Korea
1 shared publication - Ik Jae Lee
Department of Radiation Oncology, Yonsei University College of Medicine, Seoul, Korea
1 shared publication
Latest Publications
- Open Access
Comparison of Dose Distribution in Regional Lymph Nodes in Whole-Breast Radiotherapy vs. Whole-Breast Plus Regional Lymph Node Irradiation: An In Silico Planning Study in Participating Institutions of the Phase III Randomized Trial (KROG 1701)
The purpose of the current in silico planning study is to compare radiation doses of whole-breast irradiation (WBI) and whole-breast plus regional lymph node irradiation (WBI+RNI) administered to the regional lymph nodes (RLN) in pN1 breast cancer. Twenty-four participating institutions were asked to create plans of WBI and WBI+RNI for two dummy cases. To compare target coverage between the participants, an isodose line equal to 90% of the prescribed dose was converted to an isodose contour (contour90% iso). The relative nodal dose (RND) was obtained using the ratio of RLN dose to the target dose. The Fleiss’s kappa values which represent inter-observer agreement of contour90% iso were over 0.68. For RNI, 6 institutions included axillary lymph node (ALN), supraclavicular lymph node (SCN), and internal mammary lymph node (IMN), while 18 hospitals included only ALN and SCN. The median RND between the WBI and WBI+RNI were as follows: 0.64 vs. 1.05 (ALN level I), 0.27 vs. 1.08 (ALN level II), 0.02 vs. 1.12 (ALN level III), 0.01 vs. 1.12 (SCN), and 0.54 vs. 0.82 (IMN). In all nodal regions, the RND was significantly lower in WBI than in WBI+RNI (p < 0.01). In this study, we could identify the nodal dose difference between WBI and WBI+RNI.
Open AccessComparison of Dose Distribution in Regional Lymph Nodes in Whole-Breast Radiotherapy vs. Whole-Breast Plus Regional Lymph Node Irradiation: An In Silico Planning Study in Participating Institutions of the Phase III Randomized Trial (KROG 1701)
The purpose of the current in silico planning study is to compare radiation doses of whole-breast irradiation (WBI) and whole-breast plus regional lymph node irradiation (WBI+RNI) administered to the regional lymph nodes (RLN) in pN1 breast cancer. Twenty-four participating institutions were asked to create plans of WBI and WBI+RNI for two dummy cases. To compare target coverage between the participants, an isodose line equal to 90% of the prescribed dose was converted to an isodose contour (contour90% iso). The relative nodal dose (RND) was obtained using the ratio of RLN dose to the target dose. The Fleiss’s kappa values which represent inter-observer agreement of contour90% iso were over 0.68. For RNI, 6 institutions included axillary lymph node (ALN), supraclavicular lymph node (SCN), and internal mammary lymph node (IMN), while 18 hospitals included only ALN and SCN. The median RND between the WBI and WBI+RNI were as follows: 0.64 vs. 1.05 (ALN level I), 0.27 vs. 1.08 (ALN level II), 0.02 vs. 1.12 (ALN level III), 0.01 vs. 1.12 (SCN), and 0.54 vs. 0.82 (IMN). In all nodal regions, the RND was significantly lower in WBI than in WBI+RNI (p < 0.01). In this study, we could identify the nodal dose difference between WBI and WBI+RNI.