Michael Priestley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Michael Priestley has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Asan Bacak
School of Earth, Atmospheric and Environmental Sciences, University of Manchester, Oxford Road, Manchester M13 9PL, UK
1 shared publication - Carl J. Percival
Jet Propulsion Laboratory, California Institute of Technology, 4800 Oak Grove Drive, Pasadena, California 91109-8099, United States
1 shared publication - Damien Martin
Atmospheric Chemistry Research Group, School of Chemistry, Cantock’s Close, University of Bristol, Bristol BS8 1TS, UK
1 shared publication - Dudley Edmund Shallcross
School of Chemistry, University of Bristol, Bristol BS8 1TS, UK
1 shared publication - James Matthews
IEEE-USA
1 shared publication - Matthew D. Wright
H. H. Wills Physics Laboratory, University of Bristol, Tyndall Avenue, Bristol, BS8 1TL, UK; Atmospheric Chemistry Research Group, School of Chemistry, University of Bristol, Cantock's Close, Bristol, BS8 1TS, UK
1 shared publication
Latest Publications
- Open Access
- 21 February 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 14 (2) , 214
Urban Pollutant Transport and Infiltration into Buildings Using Perfluorocarbon Tracers
People spend the majority of their time indoors and therefore the quality of indoor air is worthy of investigation; indoor air quality is affected by indoor sources of pollutants and from pollutants entering buildings from outdoors. In this study, unique perfluorocarbon tracers were released in five experiments at a 100 m and ~2 km distance from a large university building in Manchester, UK and tracer was also released inside the building to measure the amount of outdoor material penetrating into buildings and the flow of material within the building itself. Air samples of the tracer were taken in several rooms within the building, and a CO2 tracer was used within the building to estimate air-exchange rates. Air-exchange rates were found to vary between 0.57 and 10.90 per hour. Indoor perfluorocarbon tracer concentrations were paired to outdoor tracer concentrations, and in-out ratios were found to vary between 0.01 and 3.6. The largest room with the lowest air-exchange rate exhibited elevated tracer concentrations for over 60 min after the release had finished, but generally had the lowest concentrations, the room with the highest ventilation rates had the highest concentration over 30 min, but the peak decayed more rapidly. Tracer concentrations indoors compared to outdoors imply that pollutants remain within buildings after they have cleared outside, which must be considered when evaluating human exposure to outdoor pollutants.
- 21 February 2017
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 14 (2) , 214
Open AccessUrban Pollutant Transport and Infiltration into Buildings Using Perfluorocarbon Tracers
People spend the majority of their time indoors and therefore the quality of indoor air is worthy of investigation; indoor air quality is affected by indoor sources of pollutants and from pollutants entering buildings from outdoors. In this study, unique perfluorocarbon tracers were released in five experiments at a 100 m and ~2 km distance from a large university building in Manchester, UK and tracer was also released inside the building to measure the amount of outdoor material penetrating into buildings and the flow of material within the building itself. Air samples of the tracer were taken in several rooms within the building, and a CO2 tracer was used within the building to estimate air-exchange rates. Air-exchange rates were found to vary between 0.57 and 10.90 per hour. Indoor perfluorocarbon tracer concentrations were paired to outdoor tracer concentrations, and in-out ratios were found to vary between 0.01 and 3.6. The largest room with the lowest air-exchange rate exhibited elevated tracer concentrations for over 60 min after the release had finished, but generally had the lowest concentrations, the room with the highest ventilation rates had the highest concentration over 30 min, but the peak decayed more rapidly. Tracer concentrations indoors compared to outdoors imply that pollutants remain within buildings after they have cleared outside, which must be considered when evaluating human exposure to outdoor pollutants.