Kamel Srairi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kamel Srairi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Belkacem Mahdad
Department of Electrical Engineering, University of Biskra, Biskra, Algeria
6 shared publications - Tarek Bouktir
Université Ferhat ABBAS Sétif 1
5 shared publications - Belkacem Mahdad
University of Biskra
2 shared publications - Chouaib Labiod
Department of Mechanical Engineering, University of El Oued, El Oued, Algeria
2 shared publications - M. Bahri
University of Biskra
1 shared publication M. E. H. Benbouzid
University of Brest, FRE CNRS 3744 IRDL
1 shared publication
Latest Publications
- Open Access
- 23 December 2018
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 16 (4) , 459 - 470-470
Application of a Novel Modified Hybrid Algorithm for Solving Dynamic Economic Dispatch Problem with Practical Constraints
Application of a Novel Modified Hybrid Algorithm for Solving Dynamic Economic Dispatch Problem with Practical Constraints
- 23 December 2018
- Published by VSB - Technical University of Ostrava in Advances in Electrical and Electronic Engineering
- Vol. 16 (4) , 459 - 470-470
Open AccessApplication of a Novel Modified Hybrid Algorithm for Solving Dynamic Economic Dispatch Problem with Practical Constraints
Application of a Novel Modified Hybrid Algorithm for Solving Dynamic Economic Dispatch Problem with Practical Constraints
- 27 March 2017
- Published by Springer Nature in Electrical Engineering
- Vol. 100 (2) , 481-490
A novel control technique for torque ripple minimization in switched reluctance motor through destructive interference
- 27 March 2017
- Published by Springer Nature in Electrical Engineering
- Vol. 100 (2) , 481-490
A novel control technique for torque ripple minimization in switched reluctance motor through destructive interference
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1-6
Flexible Methodology Based in Fuzzy Logic Rules for Reactive Power Planning of Multiple Shunt FACTS Devices to Enhance System Loadability
The problem of finding out which positions are the most effective and how many flexible AC transmission system (FACTS) devices have to be installed and controlled in a deregulated environment on economic basis is a question of great significance for the dispatcher. This paper presents a flexible approach based in practical reasoning rules from fuzzy logic theory capable of governing multiple static VAr compensator (SVC) and a group of static compensator (STATCOM) by a flexible adjustment of reactive power injected or absorbed from the network. The main purpose of the presented coordinated strategy is the improvement of index power quality. Reactive index sensitivity coordinated with an expert rules to form a global database as a flexible tool to make an efficient decision about reactive power dispatch and to choose the size of the shunt FACTS controllers. Simulation results show clearly the advantage of this approach to enhance the reactive power planning.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1-6
Flexible Methodology Based in Fuzzy Logic Rules for Reactive Power Planning of Multiple Shunt FACTS Devices to Enhance System Loadability
The problem of finding out which positions are the most effective and how many flexible AC transmission system (FACTS) devices have to be installed and controlled in a deregulated environment on economic basis is a question of great significance for the dispatcher. This paper presents a flexible approach based in practical reasoning rules from fuzzy logic theory capable of governing multiple static VAr compensator (SVC) and a group of static compensator (STATCOM) by a flexible adjustment of reactive power injected or absorbed from the network. The main purpose of the presented coordinated strategy is the improvement of index power quality. Reactive index sensitivity coordinated with an expert rules to form a global database as a flexible tool to make an efficient decision about reactive power dispatch and to choose the size of the shunt FACTS controllers. Simulation results show clearly the advantage of this approach to enhance the reactive power planning.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 312-317
A Dynamic Methodology Based in Hybrid Genetic and Fuzzy Logic Rules with Multi Shunt FACTS Devices to Enhance the Optimal Power Flow
In this paper an hybrid Genetic Algorithm and Fuzzy Logic rules is proposed to minimize the generator fuel cost with multi shunt Flexible AC Transmission Systems (FACTS). The problem is decomposed into, the optimal power generation subproblem that is searched by Genetic Algorithm and a simple practical reasoning fuzzy rules subproblem to control the reactive power exchanged with the network. The proposed method guarantees the near optimal solution and remarkably reduces the computation time. A global database generated based in reactive index sensitivity (RIS) as a flexible tool to choose economically the size of the shunt FACTS devices. This proposed approach is implemented with Matlab program with various case studies, and compared with conventional method and genetic algorithm (GA). The results show that the HGF can converge to optimum solution faster than other methods, and obtains the solution with high accuracy.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 312-317
A Dynamic Methodology Based in Hybrid Genetic and Fuzzy Logic Rules with Multi Shunt FACTS Devices to Enhance the Optimal Power Flow
In this paper an hybrid Genetic Algorithm and Fuzzy Logic rules is proposed to minimize the generator fuel cost with multi shunt Flexible AC Transmission Systems (FACTS). The problem is decomposed into, the optimal power generation subproblem that is searched by Genetic Algorithm and a simple practical reasoning fuzzy rules subproblem to control the reactive power exchanged with the network. The proposed method guarantees the near optimal solution and remarkably reduces the computation time. A global database generated based in reactive index sensitivity (RIS) as a flexible tool to choose economically the size of the shunt FACTS devices. This proposed approach is implemented with Matlab program with various case studies, and compared with conventional method and genetic algorithm (GA). The results show that the HGF can converge to optimum solution faster than other methods, and obtains the solution with high accuracy.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 285-290
A Methodology Based in Fuzzy Logic Rules for Reactive Power Planning of Multiple Shunt FACTS Devices to Enhance System Loadability
The problem of finding out which positions are the most effective and how many Flexible AC Transmission System (FACTS) devices have to be installed and controlled in a deregulated environment on economic basis is a question of great significance for the Dispatcher. This paper presents a flexible approach based in practical reasoning rules from fuzzy logic theory capable of governing multiple Static Var Compensator (SVC) and a group of Static Compensator (STATCOM) by a flexible adjustment of reactive power injected or absorbed from the network. The main purpose of the presented coordinated strategy is the improvement of system loadability. Reactive index sensitivity coordinated with an expert rules to form a global database as a flexible tool to make an efficient decision about reactive power dispatch and to choose the size of the shunt FACTS Controllers. Simulation results show clearly the advantage of this approach to enhance the reactive power planning.
- 1 April 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 285-290
A Methodology Based in Fuzzy Logic Rules for Reactive Power Planning of Multiple Shunt FACTS Devices to Enhance System Loadability
The problem of finding out which positions are the most effective and how many Flexible AC Transmission System (FACTS) devices have to be installed and controlled in a deregulated environment on economic basis is a question of great significance for the Dispatcher. This paper presents a flexible approach based in practical reasoning rules from fuzzy logic theory capable of governing multiple Static Var Compensator (SVC) and a group of Static Compensator (STATCOM) by a flexible adjustment of reactive power injected or absorbed from the network. The main purpose of the presented coordinated strategy is the improvement of system loadability. Reactive index sensitivity coordinated with an expert rules to form a global database as a flexible tool to make an efficient decision about reactive power dispatch and to choose the size of the shunt FACTS Controllers. Simulation results show clearly the advantage of this approach to enhance the reactive power planning.
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
- No. 1553572X,p. 2238-2243
A Three-Phase Power Flow Modelization: A Tool for Optimal Location and Control of FACTS Devices in Unbalanced Power Systems
The paper presents a three-phase power flow modelization: a tool for optimal location and control of FACTS devices in unbalanced power systems. The results obtained from single-phase power systems may be unrealistic and could not be able to characterize accurately the voltage stability problem of unbalanced power systems. In order to assess and investigate the importance of the three-phase power flow model proposed, a three-phase SVC model is implemented to regulate and control the reactive power injected or absorbed in the unbalanced three-phase power systems. It is strongly recommended that before location and implementation of new FACTS devices, a three-phase load flow modelling and study be made to find the best performance and arrangement. Numerical examples tested on the 5-Bus and 30-Bus IEEE system have demonstrated the approach proposed is effective
- 1 November 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IECON 2006 - 32nd Annual Conference on IEEE Industrial Electronics
- No. 1553572X,p. 2238-2243
A Three-Phase Power Flow Modelization: A Tool for Optimal Location and Control of FACTS Devices in Unbalanced Power Systems
The paper presents a three-phase power flow modelization: a tool for optimal location and control of FACTS devices in unbalanced power systems. The results obtained from single-phase power systems may be unrealistic and could not be able to characterize accurately the voltage stability problem of unbalanced power systems. In order to assess and investigate the importance of the three-phase power flow model proposed, a three-phase SVC model is implemented to regulate and control the reactive power injected or absorbed in the unbalanced three-phase power systems. It is strongly recommended that before location and implementation of new FACTS devices, a three-phase load flow modelling and study be made to find the best performance and arrangement. Numerical examples tested on the 5-Bus and 30-Bus IEEE system have demonstrated the approach proposed is effective
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2966-2971
Optimal Location and Control of FACTS Device in Unbalanced Power Systems Using Sequence Compnent
The paper presents a three-phase power flow modelization: A tool for optimal location and control of FACTS devices in unbalanced power systems. The results obtained from single-phase power systems may be unrealistic and could not be able to characterize accurately the voltage stability problem of unbalanced power systems. In order to assess and investigate the importance of the three-phase power flow model proposed, a three-phase SVC model is implemented to regulate and control the reactive power injected or absorbed in the unbalanced three-phase power systems. It is strongly recommended that before location and implementation of new FACTS devices, a three-phase load flow modelling and study be made to find the best performance and arrangement. Numerical examples tested on the 5-Bus and 30-Bus IEEE system have demonstrated the approach proposed is effective.
- 1 January 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 2966-2971
Optimal Location and Control of FACTS Device in Unbalanced Power Systems Using Sequence Compnent
The paper presents a three-phase power flow modelization: A tool for optimal location and control of FACTS devices in unbalanced power systems. The results obtained from single-phase power systems may be unrealistic and could not be able to characterize accurately the voltage stability problem of unbalanced power systems. In order to assess and investigate the importance of the three-phase power flow model proposed, a three-phase SVC model is implemented to regulate and control the reactive power injected or absorbed in the unbalanced three-phase power systems. It is strongly recommended that before location and implementation of new FACTS devices, a three-phase load flow modelling and study be made to find the best performance and arrangement. Numerical examples tested on the 5-Bus and 30-Bus IEEE system have demonstrated the approach proposed is effective.