Balaji Harinathan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Balaji Harinathan has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Narayan Yoganandan
Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, USA
7 shared publications - Aditya Vedantam
Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, USA
5 shared publications - Karthik Banurekha Devaraj
Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA
4 shared publications - Mahmudur Rahman
Department of Neurosurgery, Medical College of Wisconsin, Milwaukee, WI 53226, USA
2 shared publications - Alok S. Shah
Department of Neurosurgery, Medical College of Wisconsin , Milwaukee, WI 53295
1 shared publication - Andrew DeGroot
Department of Neurosurgery
1 shared publication
Latest Publications
- Open Access
- 17 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 886
Intramedullary Stress and Strain Correlate with Neurological Dysfunction in Degenerative Cervical Myelopathy
Degenerative cervical myelopathy (DCM) is characterized by progressive neurological dysfunction, yet the contribution of intramedullary stress and strain during neck motion remains unclear. This study used patient-specific finite element models (FEMs) of the cervical spine and spinal cord to examine the relationship between spinal cord biomechanics and neurological dysfunction. Twenty DCM patients (mean age 62.7 ± 11.6 years; thirteen females) underwent pre-surgical MRI-based modeling to quantify von Mises stress and maximum principal strains at the level of maximum spinal cord compression during simulated neck flexion and extension. Pre-surgical functional assessments included hand sensation, dexterity, and balance. During flexion, the mean intramedullary stress and strain at the level of maximum compression were 7.6 ± 3.7 kPa and 4.3 ± 2.0%, respectively. Increased intramedullary strain during flexion correlated with decreased right-hand sensation (r = −0.58, p = 0.014), impaired right-hand dexterity (r = −0.50, p = 0.048), and prolonged dexterity time (r = 0.52, p = 0.039). Similar correlations were observed with intramedullary stress. Patients with severe DCM exhibited significantly greater stress during flexion than those with mild/moderate disease (p = 0.03). These findings underscore the impact of dynamic spinal cord biomechanics on neurological dysfunction and support their potential utility in improving DCM diagnosis and management.
- 17 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 886
Open AccessIntramedullary Stress and Strain Correlate with Neurological Dysfunction in Degenerative Cervical Myelopathy
Degenerative cervical myelopathy (DCM) is characterized by progressive neurological dysfunction, yet the contribution of intramedullary stress and strain during neck motion remains unclear. This study used patient-specific finite element models (FEMs) of the cervical spine and spinal cord to examine the relationship between spinal cord biomechanics and neurological dysfunction. Twenty DCM patients (mean age 62.7 ± 11.6 years; thirteen females) underwent pre-surgical MRI-based modeling to quantify von Mises stress and maximum principal strains at the level of maximum spinal cord compression during simulated neck flexion and extension. Pre-surgical functional assessments included hand sensation, dexterity, and balance. During flexion, the mean intramedullary stress and strain at the level of maximum compression were 7.6 ± 3.7 kPa and 4.3 ± 2.0%, respectively. Increased intramedullary strain during flexion correlated with decreased right-hand sensation (r = −0.58, p = 0.014), impaired right-hand dexterity (r = −0.50, p = 0.048), and prolonged dexterity time (r = 0.52, p = 0.039). Similar correlations were observed with intramedullary stress. Patients with severe DCM exhibited significantly greater stress during flexion than those with mild/moderate disease (p = 0.03). These findings underscore the impact of dynamic spinal cord biomechanics on neurological dysfunction and support their potential utility in improving DCM diagnosis and management.
- Open Access
- 31 December 2024
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 18 (6) , 777-793
Comparing adjacent segment biomechanics between anterior and posterior cervical fusion using patient-specific finite element modeling
Study Design: This study employed a patient-specific finite element model.Purpose: To quantify the effect of anterior and posterior surgical approaches on adjacent segment biomechanics of the patient-specific spine and spinal cord.Overview of Literature: Adjacent segment degeneration (ASD) is a well-documented complication following cervical fusion, typically resulting from accelerated osteoligamentous deterioration and subsequent symptomatic neural compression. Despite the known impact of spinal fusion on adjacent segment biomechanics, comprehensive comparison between anterior and posterior surgical approaches remains elusive. Understanding these biomechanical changes is crucial for predicting and managing ASD, thereby aiding preoperative surgical planning.Methods: Patient-specific finite element modeling (FEM) of the cervical spine and spinal cord were created. Surgical simulation was performed for multi-segment anterior cervical discectomy fusion (ACDF) (C4–C7) and posterior cervical laminectomy with fusion (PCLF) (C5–6 laminectomy and C4–C7 fusion). Physiological motions were simulated by applying a 2 Nm moment and 75 N force.Results: At the superior adjacent segment, the ACDF model exhibited a higher range of motion (ROM) during neck flexion compared to PCLF. Conversely, in neck extension, PCLF showed a higher ROM than ACDF. At the superior adjacent segment, the ACDF model showed greater spinal cord stress during flexion. During extension, PCLF was associated with greater spinal cord stress. At the inferior adjacent segment, ACDF was associated with greater spinal cord stress than PCLF during flexion. At the superior adjacent segment, ACDF also led to increased intradiskal pressure and capsular ligament strain during flexion, whereas PCLF showed these increases during extension.Conclusions: Our findings indicate the differential effect of ACDF and PCLF on biomechanics at the cervical spine’s adjacent segments, with the patient-specific model with ACDF showing greater changes and potential for degeneration. This study highlights the utility of patient-specific FEMs in enhancing surgical decision-making through personalized medicine.
- 31 December 2024
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 18 (6) , 777-793
Open AccessComparing adjacent segment biomechanics between anterior and posterior cervical fusion using patient-specific finite element modeling
Study Design: This study employed a patient-specific finite element model.Purpose: To quantify the effect of anterior and posterior surgical approaches on adjacent segment biomechanics of the patient-specific spine and spinal cord.Overview of Literature: Adjacent segment degeneration (ASD) is a well-documented complication following cervical fusion, typically resulting from accelerated osteoligamentous deterioration and subsequent symptomatic neural compression. Despite the known impact of spinal fusion on adjacent segment biomechanics, comprehensive comparison between anterior and posterior surgical approaches remains elusive. Understanding these biomechanical changes is crucial for predicting and managing ASD, thereby aiding preoperative surgical planning.Methods: Patient-specific finite element modeling (FEM) of the cervical spine and spinal cord were created. Surgical simulation was performed for multi-segment anterior cervical discectomy fusion (ACDF) (C4–C7) and posterior cervical laminectomy with fusion (PCLF) (C5–6 laminectomy and C4–C7 fusion). Physiological motions were simulated by applying a 2 Nm moment and 75 N force.Results: At the superior adjacent segment, the ACDF model exhibited a higher range of motion (ROM) during neck flexion compared to PCLF. Conversely, in neck extension, PCLF showed a higher ROM than ACDF. At the superior adjacent segment, the ACDF model showed greater spinal cord stress during flexion. During extension, PCLF was associated with greater spinal cord stress. At the inferior adjacent segment, ACDF was associated with greater spinal cord stress than PCLF during flexion. At the superior adjacent segment, ACDF also led to increased intradiskal pressure and capsular ligament strain during flexion, whereas PCLF showed these increases during extension.Conclusions: Our findings indicate the differential effect of ACDF and PCLF on biomechanics at the cervical spine’s adjacent segments, with the patient-specific model with ACDF showing greater changes and potential for degeneration. This study highlights the utility of patient-specific FEMs in enhancing surgical decision-making through personalized medicine.
- 21 November 2024
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 8 (3) , 1-13
Behind Amor Blunt Trauma Lung and Liver Strains From Indenter Loading Via Finite Element Modeling
To determine behind armor blunt trauma (BABT) injury criteria, experiments have been conducted by launching blunt projectiles at live swine at velocities up to 65 meters per second (m/s) using one type of indenter design. To ensure the generalizability of the developed injury criteria, additional tests with different indenter designs are needed. The objectives of this study were to evaluate the kinematics and injury parameters from two indenter designs using human body finite element modeling. The simulation matrix consisted of chord and cylindrical shape indenter designs with two different masses of 150 and 230 grams. They were used to impact the liver and lung regions at velocities of 30 and 60 m/s using a human body model. Rib and lung strains from lung impacts and rib strain and liver strain energy densities (SED) from liver impacts were used to evaluate the design variables of mass and shape. Both designs played a role in skeletal and organ injury parameters. Analysis revealed an increased susceptibility for skeletal and organ traumas with the high mass indenter during high velocity impacts. The cylindrical indenter may be protective for organ injuries due to the larger area of loading on the ribcage compared to the chord indenter. Results from the chord indenter may serve as a conservative estimate of injury criteria.
- 21 November 2024
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 8 (3) , 1-13
Behind Amor Blunt Trauma Lung and Liver Strains From Indenter Loading Via Finite Element Modeling
To determine behind armor blunt trauma (BABT) injury criteria, experiments have been conducted by launching blunt projectiles at live swine at velocities up to 65 meters per second (m/s) using one type of indenter design. To ensure the generalizability of the developed injury criteria, additional tests with different indenter designs are needed. The objectives of this study were to evaluate the kinematics and injury parameters from two indenter designs using human body finite element modeling. The simulation matrix consisted of chord and cylindrical shape indenter designs with two different masses of 150 and 230 grams. They were used to impact the liver and lung regions at velocities of 30 and 60 m/s using a human body model. Rib and lung strains from lung impacts and rib strain and liver strain energy densities (SED) from liver impacts were used to evaluate the design variables of mass and shape. Both designs played a role in skeletal and organ injury parameters. Analysis revealed an increased susceptibility for skeletal and organ traumas with the high mass indenter during high velocity impacts. The cylindrical indenter may be protective for organ injuries due to the larger area of loading on the ribcage compared to the chord indenter. Results from the chord indenter may serve as a conservative estimate of injury criteria.
- Open Access
- 30 August 2024
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 18 (4) , 441-447
Comparative Biomechanical Analysis of Anterior Lumbar Interbody Fusion and Bilateral Expandable Transforaminal Lumbar Interbody Fusion Cages: A Finite Element Analysis Study
Background Expandable transforaminal lumbar interbody fusion (TLIF) cages could offer an alternative to anterior lumbar interbody fusion (ALIF). Bilateral cage insertion enhances endplate coverage, potentially improving stability and fusion rates and maximizing segmental lordosis. This study aims to compare the biomechanical properties of bilateral expandable TLIF cages to ALIF cages using finite element modeling. Methods We used a validated 3-dimensional finite element model of the lumbar spine. ALIF and TLIF cages were created based on available product data. Our focus was on analyzing spinal motion in the sagittal plane, evaluating forces transmitted through the vertebrae, and comparing an ALIF model with various TLIF cage models. Results The largest TLIF cage model exhibited a 407.9% increase in flexion motion and a 42.1% decrease in extension motion compared with the ALIF cage. The second largest TLIF cages resulted in more flexion motion and less extension motion compared with ALIF, while smaller cages were inferior to ALIF. ALIF cages were associated with increased adjacent segment motion compared with TLIF cages, primarily in extension. Endplate stress analysis revealed higher stress in the ALIF cage model with a more uniform stress distribution. Conclusion ALIF cages excel in stabilizing L5 to S1 during flexion, while largest TLIF cages offer superior stability in extension. Large bilateral TLIF cages may provide biomechanical stability comparable to ALIF, especially in extension and could potentially reduce the risk of adjacent segment disease with lower adjacent segment motion. Level of Evidence 5.
- 30 August 2024
- Published by International Journal of Spine Surgery in International Journal of Spine Surgery
- Vol. 18 (4) , 441-447
Open AccessComparative Biomechanical Analysis of Anterior Lumbar Interbody Fusion and Bilateral Expandable Transforaminal Lumbar Interbody Fusion Cages: A Finite Element Analysis Study
Background Expandable transforaminal lumbar interbody fusion (TLIF) cages could offer an alternative to anterior lumbar interbody fusion (ALIF). Bilateral cage insertion enhances endplate coverage, potentially improving stability and fusion rates and maximizing segmental lordosis. This study aims to compare the biomechanical properties of bilateral expandable TLIF cages to ALIF cages using finite element modeling. Methods We used a validated 3-dimensional finite element model of the lumbar spine. ALIF and TLIF cages were created based on available product data. Our focus was on analyzing spinal motion in the sagittal plane, evaluating forces transmitted through the vertebrae, and comparing an ALIF model with various TLIF cage models. Results The largest TLIF cage model exhibited a 407.9% increase in flexion motion and a 42.1% decrease in extension motion compared with the ALIF cage. The second largest TLIF cages resulted in more flexion motion and less extension motion compared with ALIF, while smaller cages were inferior to ALIF. ALIF cages were associated with increased adjacent segment motion compared with TLIF cages, primarily in extension. Endplate stress analysis revealed higher stress in the ALIF cage model with a more uniform stress distribution. Conclusion ALIF cages excel in stabilizing L5 to S1 during flexion, while largest TLIF cages offer superior stability in extension. Large bilateral TLIF cages may provide biomechanical stability comparable to ALIF, especially in extension and could potentially reduce the risk of adjacent segment disease with lower adjacent segment motion. Level of Evidence 5.
- Open Access
- 12 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (14) , 1497
Using Finite Element Models to Assess Spinal Cord Biomechanics after Cervical Laminoplasty for Degenerative Cervical Myelopathy
Cervical laminoplasty is an established motion-preserving procedure for degenerative cervical myelopathy (DCM). However, patients with pre-existing cervical kyphosis often experience inferior outcomes compared to those with straight or lordotic spines. Limited dorsal spinal cord shift in kyphotic spines post-decompression and increased spinal cord tension may contribute to poor neurological recovery and spinal cord injury. This study aims to quantify the biomechanical impact of cervical sagittal alignment on spinal cord stress and strain post-laminoplasty using a validated 3D finite element model of the C2–T1 spine. Three models were created based on the C2–C7 Cobb angle: lordosis (20 degrees), straight (0 degrees), and kyphosis (−9 degrees). Open-door laminoplasty was simulated at C4, C5, and C6 levels, followed by physiological neck flexion and extension. The results showed that spinal cord stress and strain were highest in kyphotic curvature compared to straight and lordotic curvatures across all cervical segments, despite similar segmental ROM. In flexion, kyphotic spines exhibited 103.3% higher stress and 128.9% higher strain than lordotic spines and 16.7% higher stress and 26.8% higher strain than straight spines. In extension, kyphotic spines showed 135.4% higher stress and 241.7% higher strain than lordotic spines and 21.5% higher stress and 43.2% higher strain than straight spines. The study shows that cervical kyphosis leads to increased spinal cord stress and strain post-laminoplasty, underscoring the need to address sagittal alignment in addition to decompression for optimal patient outcomes.
- 12 July 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (14) , 1497
Open AccessUsing Finite Element Models to Assess Spinal Cord Biomechanics after Cervical Laminoplasty for Degenerative Cervical Myelopathy
Cervical laminoplasty is an established motion-preserving procedure for degenerative cervical myelopathy (DCM). However, patients with pre-existing cervical kyphosis often experience inferior outcomes compared to those with straight or lordotic spines. Limited dorsal spinal cord shift in kyphotic spines post-decompression and increased spinal cord tension may contribute to poor neurological recovery and spinal cord injury. This study aims to quantify the biomechanical impact of cervical sagittal alignment on spinal cord stress and strain post-laminoplasty using a validated 3D finite element model of the C2–T1 spine. Three models were created based on the C2–C7 Cobb angle: lordosis (20 degrees), straight (0 degrees), and kyphosis (−9 degrees). Open-door laminoplasty was simulated at C4, C5, and C6 levels, followed by physiological neck flexion and extension. The results showed that spinal cord stress and strain were highest in kyphotic curvature compared to straight and lordotic curvatures across all cervical segments, despite similar segmental ROM. In flexion, kyphotic spines exhibited 103.3% higher stress and 128.9% higher strain than lordotic spines and 16.7% higher stress and 26.8% higher strain than straight spines. In extension, kyphotic spines showed 135.4% higher stress and 241.7% higher strain than lordotic spines and 21.5% higher stress and 43.2% higher strain than straight spines. The study shows that cervical kyphosis leads to increased spinal cord stress and strain post-laminoplasty, underscoring the need to address sagittal alignment in addition to decompression for optimal patient outcomes.
- 9 October 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 7 (2) , 1-23
Comparison of Load-Sharing Responses Between Graded Posterior Cervical Foraminotomy and Conventional Fusion Using Finite Element Modeling
Following the diagnosis of unilateral cervical radiculopathy and need for surgical intervention, anterior cervical diskectomy and fusion (conventional fusion) and posterior cervical foraminotomy are common options. Although patient outcomes may be similar between the two procedures, their biomechanical effects have not been fully compared using a head-to-head approach, particularly, in relation to the amount of facet resection and internal load-sharing between spinal segments and components. The objective of this investigation was to compare load-sharing between conventional fusion and graded foraminotomy facet resections under physiological loading. A validated finite element model of the cervical spinal column was used in the study. The intact spine was modified to simulate the two procedures at the C5–C6 spinal segment. Flexion, extension, and lateral bending loads were applied to the intact, graded foraminotomy, and conventional fusion spines. Load-sharing was determined using range of motion data at the C5–C6 and immediate adjacent segments, facet loads at the three segments, and disk pressures at the adjacent segments. Results were normalized with respect to the intact spine to compare surgical options. Conventional fusion leads to increased motion, pressure, and facet loads at adjacent segments. Foraminotomy leads to increased motion and anterior loading at the index level, and motions decrease at adjacent levels. In extension, the left facet load decreases after foraminotomy. Recognizing that foraminotomy is a motion preserving alternative to conventional fusion, this study highlights various intrinsic biomechanical factors and potential instability issues with more than one-half facet resection.
- 9 October 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 7 (2) , 1-23
Comparison of Load-Sharing Responses Between Graded Posterior Cervical Foraminotomy and Conventional Fusion Using Finite Element Modeling
Following the diagnosis of unilateral cervical radiculopathy and need for surgical intervention, anterior cervical diskectomy and fusion (conventional fusion) and posterior cervical foraminotomy are common options. Although patient outcomes may be similar between the two procedures, their biomechanical effects have not been fully compared using a head-to-head approach, particularly, in relation to the amount of facet resection and internal load-sharing between spinal segments and components. The objective of this investigation was to compare load-sharing between conventional fusion and graded foraminotomy facet resections under physiological loading. A validated finite element model of the cervical spinal column was used in the study. The intact spine was modified to simulate the two procedures at the C5–C6 spinal segment. Flexion, extension, and lateral bending loads were applied to the intact, graded foraminotomy, and conventional fusion spines. Load-sharing was determined using range of motion data at the C5–C6 and immediate adjacent segments, facet loads at the three segments, and disk pressures at the adjacent segments. Results were normalized with respect to the intact spine to compare surgical options. Conventional fusion leads to increased motion, pressure, and facet loads at adjacent segments. Foraminotomy leads to increased motion and anterior loading at the index level, and motions decrease at adjacent levels. In extension, the left facet load decreases after foraminotomy. Recognizing that foraminotomy is a motion preserving alternative to conventional fusion, this study highlights various intrinsic biomechanical factors and potential instability issues with more than one-half facet resection.
- 3 October 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 7 (2) , 1-31
Cervical Column and Cord and Column Responses in Whiplash With Stenosis: A Finite Element Modeling Study
Spine degeneration is a normal aging process. It may lead to stenotic spines that may have implications for pain and quality of life. The diagnosis is based on clinical symptomatology and imaging. Magnetic resonance images often reveal the nature and degree of stenosis of the spine. Stenosis is concerning to clinicians and patients because of the decreased space in the spinal canal and potential for elevated risk of cord and/or osteoligamentous spinal column injuries. Numerous finite element models of the cervical spine have been developed to study the biomechanics of the osteoligamentous column such as range of motion and vertebral stress; however, spinal cord modeling is often ignored. The objective of this study was to determine the external column and internal cord and disc responses of stenotic spines using finite element modeling. A validated model of the subaxial spinal column was used. The osteoligamentous column was modified to include the spinal cord. Mild, moderate, and severe degrees of stenosis commonly identified in civilian populations were simulated at C5–C6. The column-cord model was subjected to postero-anterior acceleration at T1. The range of motion, disc pressure, and cord stress–strain were obtained at the index and superior and inferior adjacent levels of the stenosis. The external metric representing the segmental motion was insensitive while the intrinsic disc and cord variables were more sensitive, and the index level was more affected by stenosis. These findings may influence surgical planning and patient education in personalized medicine.
- 3 October 2023
- Published by Wiley in Journal of Engineering and Science in Medical Diagnostics and Therapy
- Vol. 7 (2) , 1-31
Cervical Column and Cord and Column Responses in Whiplash With Stenosis: A Finite Element Modeling Study
Spine degeneration is a normal aging process. It may lead to stenotic spines that may have implications for pain and quality of life. The diagnosis is based on clinical symptomatology and imaging. Magnetic resonance images often reveal the nature and degree of stenosis of the spine. Stenosis is concerning to clinicians and patients because of the decreased space in the spinal canal and potential for elevated risk of cord and/or osteoligamentous spinal column injuries. Numerous finite element models of the cervical spine have been developed to study the biomechanics of the osteoligamentous column such as range of motion and vertebral stress; however, spinal cord modeling is often ignored. The objective of this study was to determine the external column and internal cord and disc responses of stenotic spines using finite element modeling. A validated model of the subaxial spinal column was used. The osteoligamentous column was modified to include the spinal cord. Mild, moderate, and severe degrees of stenosis commonly identified in civilian populations were simulated at C5–C6. The column-cord model was subjected to postero-anterior acceleration at T1. The range of motion, disc pressure, and cord stress–strain were obtained at the index and superior and inferior adjacent levels of the stenosis. The external metric representing the segmental motion was insensitive while the intrinsic disc and cord variables were more sensitive, and the index level was more affected by stenosis. These findings may influence surgical planning and patient education in personalized medicine.