Daniel Suárez
Daniel Suárez has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jose Joaquin Rieta
BioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain
6 shared publications - Raúl Alcaraz
Research Group in Electronic, Biomedical and Telecommunication Engineering, University of Castilla-La Mancha, 16071 Cuenca, Spain
6 shared publications - Arturo Martínez-Rodrigo
COMETA Research Group, Informatics Systems Department, University of Castilla-La Mancha, 16071 Cuenca, Spain
3 shared publications - Fernando Hornero
Cardiovascular Surgery Department, Hospital Clínico Universitario de Valencia, 46010 Valencia, Spain
3 shared publications - Lorenzo Fácila
Cardiology Department, General University Hospital Consortium of Valencia, 46014 Valencia, Spain
3 shared publications - Matteo Ricci
BioMIT.org, Electronic Engineering Department, Universitat Politecnica de Valencia, 46022 Valencia, Spain
3 shared publications
Latest Publications
- Open Access
Improving Wearable PPG Monitoring with Morphology-Aware and Learning-Driven Heartbeat Detection
Photoplethysmography (PPG) is a widely used, non-invasive technique for heart rate monitoring, but its reliability is often compromised by noise and motion artifacts (MAs). This study presents the Peakwise Correlation Pulse Detector (PCPD), an algorithm for detecting heartbeats directly from PPG signals without requiring electrocardiogram (ECG) signals during operation, evaluated here under clean and controlled synthetic pulse-free-noise conditions. PCPD follows a five-step pipeline: (1) signal segmentation with overlap, (2) sliding cross-correlation using high-quality heartbeat templates, (3) computation of the Minimum Correlation Curve (MCC), (4) feature extraction with machine learning-based classification, and (5) peak translation with constraint analysis. The method was evaluated on a clean dataset, comprising a newly collected PPG dataset with manually annotated signal quality and the publicly available BIDMC dataset, and on a noisy dataset that augments the clean data with synthetic pulse-free segments generated from band-limited Gaussian noise. This evaluation framework tests heartbeat detectors under ideal conditions and under a controlled non-informative-noise protocol. On clean signals, PCPD achieved balanced precision–recall scores of 99.13% on the proposed dataset (internal performance) and 97.04% on the independent BIDMC dataset. Under added synthetic pulse-free noise, PCPD achieved accuracies of 99.30% and 97.16% on the proposed and BIDMC datasets, respectively. In comparative experiments against eleven benchmark heartbeat detection algorithms, PCPD achieved the best performance among the evaluated implementations under the tested synthetic-noise protocol. These results support PCPD as a promising PPG-only peak detector and motivate further validation under real motion artifacts and for downstream signal quality assessment.
Open AccessImproving Wearable PPG Monitoring with Morphology-Aware and Learning-Driven Heartbeat Detection
Photoplethysmography (PPG) is a widely used, non-invasive technique for heart rate monitoring, but its reliability is often compromised by noise and motion artifacts (MAs). This study presents the Peakwise Correlation Pulse Detector (PCPD), an algorithm for detecting heartbeats directly from PPG signals without requiring electrocardiogram (ECG) signals during operation, evaluated here under clean and controlled synthetic pulse-free-noise conditions. PCPD follows a five-step pipeline: (1) signal segmentation with overlap, (2) sliding cross-correlation using high-quality heartbeat templates, (3) computation of the Minimum Correlation Curve (MCC), (4) feature extraction with machine learning-based classification, and (5) peak translation with constraint analysis. The method was evaluated on a clean dataset, comprising a newly collected PPG dataset with manually annotated signal quality and the publicly available BIDMC dataset, and on a noisy dataset that augments the clean data with synthetic pulse-free segments generated from band-limited Gaussian noise. This evaluation framework tests heartbeat detectors under ideal conditions and under a controlled non-informative-noise protocol. On clean signals, PCPD achieved balanced precision–recall scores of 99.13% on the proposed dataset (internal performance) and 97.04% on the independent BIDMC dataset. Under added synthetic pulse-free noise, PCPD achieved accuracies of 99.30% and 97.16% on the proposed and BIDMC datasets, respectively. In comparative experiments against eleven benchmark heartbeat detection algorithms, PCPD achieved the best performance among the evaluated implementations under the tested synthetic-noise protocol. These results support PCPD as a promising PPG-only peak detector and motivate further validation under real motion artifacts and for downstream signal quality assessment.
- Open Access
A Novel Cluster-Based Approach for PPG Signal Preprocessing: Motion Artifact Filtering and Ambient Light Correction
Photoplethysmography (PPG) is widely used in wearable devices, but wrist- and arm-worn recordings are sensitive to motion artifacts, ambient light, and changes in sensor–skin contact. This study presents an adaptive preprocessing pipeline that combines accelerometer-derived motion-state clustering, an ambient-light-based Contact Quality Index (CQI), and cluster-based Symlet 4 wavelet filtering. Motion states are obtained from less posture-dependent features of 10 s accelerometer windows, whereas the CQI is a heuristic indicator of ambient-light-related optical reliability, scaled from 0 to 1, that flags low-reliability segments without changing their motion label. The wavelet stage removes baseline drift, soft-thresholds the high-frequency detail bands with thresholds selected on training data, and preserves the bands that overlap the cardiac frequency range. The model was trained on 8 participants and evaluated on 27 held-out participants against a simultaneously recorded ECG. Compared with a band-pass filter and an accelerometer-referenced adaptive filter, the proposed method detected more beats (median sensitivity 1.00 vs. 0.91 and 0.92) and reduced the inter-beat-interval (IBI) error when missed beats were included (128.0 vs. 181.2 and 156.8 ms), particularly during movement, at the cost of a lower positive predictive value (0.92 vs. 1.00), whereas the reference filters yielded lower IBI error on detected beats (24.6 and 26.6 vs. 38.7 ms). The method also outperformed a fixed Daubechies 4 wavelet filter on all timing metrics. In a band-energy analysis, it reduced out-of-band energy by a median of 27.7 dB but also reduced useful-band energy by 41.0%. These results show that a lightly thresholded wavelet filter recovers more beats than fixed filters during daily-life movement, whereas the benefit of cluster-specific thresholds remains to be established in other cohorts and during higher-intensity activities.
Open AccessA Novel Cluster-Based Approach for PPG Signal Preprocessing: Motion Artifact Filtering and Ambient Light Correction
Photoplethysmography (PPG) is widely used in wearable devices, but wrist- and arm-worn recordings are sensitive to motion artifacts, ambient light, and changes in sensor–skin contact. This study presents an adaptive preprocessing pipeline that combines accelerometer-derived motion-state clustering, an ambient-light-based Contact Quality Index (CQI), and cluster-based Symlet 4 wavelet filtering. Motion states are obtained from less posture-dependent features of 10 s accelerometer windows, whereas the CQI is a heuristic indicator of ambient-light-related optical reliability, scaled from 0 to 1, that flags low-reliability segments without changing their motion label. The wavelet stage removes baseline drift, soft-thresholds the high-frequency detail bands with thresholds selected on training data, and preserves the bands that overlap the cardiac frequency range. The model was trained on 8 participants and evaluated on 27 held-out participants against a simultaneously recorded ECG. Compared with a band-pass filter and an accelerometer-referenced adaptive filter, the proposed method detected more beats (median sensitivity 1.00 vs. 0.91 and 0.92) and reduced the inter-beat-interval (IBI) error when missed beats were included (128.0 vs. 181.2 and 156.8 ms), particularly during movement, at the cost of a lower positive predictive value (0.92 vs. 1.00), whereas the reference filters yielded lower IBI error on detected beats (24.6 and 26.6 vs. 38.7 ms). The method also outperformed a fixed Daubechies 4 wavelet filter on all timing metrics. In a band-energy analysis, it reduced out-of-band energy by a median of 27.7 dB but also reduced useful-band energy by 41.0%. These results show that a lightly thresholded wavelet filter recovers more beats than fixed filters during daily-life movement, whereas the benefit of cluster-specific thresholds remains to be established in other cohorts and during higher-intensity activities.
- 4 June 2026
- Published by Springer Nature
- p. 162-167
Context-Aware Wavelet Denoising of PPG Signals Using Clustered Accelerometer Features
- 4 June 2026
- Published by Springer Nature
- p. 162-167
Context-Aware Wavelet Denoising of PPG Signals Using Clustered Accelerometer Features
- 4 June 2026
- Published by Springer Nature
- p. 187-193
A Template-Based and Learning-Driven Method for Reliable Heartbeat Detection in Wearable PPG
- 4 June 2026
- Published by Springer Nature
- p. 187-193
A Template-Based and Learning-Driven Method for Reliable Heartbeat Detection in Wearable PPG
- 4 June 2026
- Published by Springer Nature
- p. 155-161
A Spectral Approach to Evaluating PPG Signal Quality Under Ambient Light Interference
- 4 June 2026
- Published by Springer Nature
- p. 155-161
A Spectral Approach to Evaluating PPG Signal Quality Under Ambient Light Interference
- Open Access
- 14 June 2024
- Published by Heighten Science Publications Corporation in Journal of Forensic Science and Research
- Vol. 8 (1) , 016-018
What to do from the Emergency Room in Case of Suspected Chemical Submission
Chemical submission is a crime where criminals use substances to impose their will on victims. A 44-year-old woman comes to the Health Center disoriented in the temporal sphere, stating that “she does not remember what happened.” Her brother, the companion who brings her to the health center, says that he has found her in a place he does not usually frequent. The patient missed a bag she was carrying and could not locate her mobile phone. The patient and companion suspect that she may have been “drugged” in order to rob them. Given the suspicion that the patient may have been a victim of chemical submission, the Emergency Service is called to inform that the victim is going to be referred. The detection of biological samples of the substances used for submission is of vital importance.
- 14 June 2024
- Published by Heighten Science Publications Corporation in Journal of Forensic Science and Research
- Vol. 8 (1) , 016-018
Open AccessWhat to do from the Emergency Room in Case of Suspected Chemical Submission
Chemical submission is a crime where criminals use substances to impose their will on victims. A 44-year-old woman comes to the Health Center disoriented in the temporal sphere, stating that “she does not remember what happened.” Her brother, the companion who brings her to the health center, says that he has found her in a place he does not usually frequent. The patient missed a bag she was carrying and could not locate her mobile phone. The patient and companion suspect that she may have been “drugged” in order to rob them. Given the suspicion that the patient may have been a victim of chemical submission, the Emergency Service is called to inform that the victim is going to be referred. The detection of biological samples of the substances used for submission is of vital importance.
- 29 August 2023
- Published by Springer Nature
- p. 97-106
Development of an Immersive Virtual Reality System to Practice the Lumbar Puncture Manoeuvre
- 29 August 2023
- Published by Springer Nature
- p. 97-106
Development of an Immersive Virtual Reality System to Practice the Lumbar Puncture Manoeuvre
- 1 June 2018
- Published by Elsevier in Forensic Science International
- Vol. 287, e10-E10
Improving detection window of scopolamine
- 1 June 2018
- Published by Elsevier in Forensic Science International
- Vol. 287, e10-E10
Improving detection window of scopolamine