Lei Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lei Zhang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
Binwen Wang
Aircraft Strength Research Institute of China, Xian, China
1 shared publication- Hao Wu
Ultrasound Department, The Second Affiliated Hospital of Zhejiang Chinese Medical University, Hangzhou, People’s Republic of China
1 shared publication - Hebin Zhang
Department of Ultrasound The Affiliated Hospital of Hangzhou Normal University Hangzhou China
1 shared publication Huiyang Wang
Department of Ultrasound Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, 310003, China
1 shared publicationJijun Liu
National Key Laboratory of Strength and Structural Integrity, Xian, China
1 shared publicationLaizhi Zhang
Department of Otolaryngology, Zhejiang Armed Police Force Corps Hospital, Hangzhou, 310005, China
1 shared publication
Latest Publications
- 12 March 2026
- Published by Springer Nature in International Journal of Aeronautical and Space Sciences
- Vol. 27 (4) , 1-17
Dynamic Response and Rapid Analysis of the Aircraft Model Vibration in Transonic Wind Tunnels
- 12 March 2026
- Published by Springer Nature in International Journal of Aeronautical and Space Sciences
- Vol. 27 (4) , 1-17
Dynamic Response and Rapid Analysis of the Aircraft Model Vibration in Transonic Wind Tunnels
- 1 October 2023
- Published by American Scientific Publishers in Journal of Biomedical Nanotechnology
- Vol. 19 (10) , 1762-1771
Ultrasound-Mediated Destruction of P-Selectin-Targeted and Cannabinoid Type 2 Receptor Agonist-Loading Microbubbles Ameliorates Skeletal Muscle Ischemia-Reperfusion Injury in Rat
Current study aims to explore the ameliorative effects of ultrasound in combination with P-selectin-targeted/AM1241-loaded microbubbles (AM1241 MBs) in rats with skeletal muscle ischemia/reperfusion (I/R) injury. AM1241 MB was prepared via rotary evaporation and mechanical shaking. Histological lesions and cellular apoptosis in skeletal muscle were detected by H&E staining and TUNEL staining, respectively. Changes in antioxidant capacity and inflammatory response in skeletal muscle tissue were analyzed by ELISA method. Changes of Nfr2/HO-1 pathway-related proteins were measured via the western blot. As a result, ultrasound-mediated destruction of AM1241 MBs significantly improved the degree of damage and edema in skeletal muscle tissue of rats with I/R injury. Inflammatory response and cellular apoptosis in skeletal muscle tissue were also significantly improved, while the antioxidant capacity was significantly enhanced. Western blot analysis exhibited that ultrasound in combination with AM1241 MBs treatment activated the Nrf2/HO-1 pathway. Nevertheless, selective knockdown of Nrf2 significantly reversed the beneficial effects of ultrasound combined with AM1241 MBs treatment on I/R injuries of the skeletal muscle. Ultrasound-mediated disruption of AM1241 MBs could effectively ameliorate the I/R injuries of skeletal muscle tissues in rats via activating the Nrf2/HO-1 pathway.
- 1 October 2023
- Published by American Scientific Publishers in Journal of Biomedical Nanotechnology
- Vol. 19 (10) , 1762-1771
Ultrasound-Mediated Destruction of P-Selectin-Targeted and Cannabinoid Type 2 Receptor Agonist-Loading Microbubbles Ameliorates Skeletal Muscle Ischemia-Reperfusion Injury in Rat
Current study aims to explore the ameliorative effects of ultrasound in combination with P-selectin-targeted/AM1241-loaded microbubbles (AM1241 MBs) in rats with skeletal muscle ischemia/reperfusion (I/R) injury. AM1241 MB was prepared via rotary evaporation and mechanical shaking. Histological lesions and cellular apoptosis in skeletal muscle were detected by H&E staining and TUNEL staining, respectively. Changes in antioxidant capacity and inflammatory response in skeletal muscle tissue were analyzed by ELISA method. Changes of Nfr2/HO-1 pathway-related proteins were measured via the western blot. As a result, ultrasound-mediated destruction of AM1241 MBs significantly improved the degree of damage and edema in skeletal muscle tissue of rats with I/R injury. Inflammatory response and cellular apoptosis in skeletal muscle tissue were also significantly improved, while the antioxidant capacity was significantly enhanced. Western blot analysis exhibited that ultrasound in combination with AM1241 MBs treatment activated the Nrf2/HO-1 pathway. Nevertheless, selective knockdown of Nrf2 significantly reversed the beneficial effects of ultrasound combined with AM1241 MBs treatment on I/R injuries of the skeletal muscle. Ultrasound-mediated disruption of AM1241 MBs could effectively ameliorate the I/R injuries of skeletal muscle tissues in rats via activating the Nrf2/HO-1 pathway.
- 22 August 2023
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 35 (1) , 68-80
An active piezoelectric damping vibration control system for the sting used in wind tunnel
In wind tunnel tests, the cantilever sting supporting system often suffers from low-frequency and large-amplitude resonance due to its inherent low structural damping characteristic, resulting in the degradation of data quality and structural safety. To improve wind tunnel testing safety and data accuracy, this paper is dedicated to establish an active vibration control system using piezoelectric stack actuators. A novel methodology of vibration monitoring based on modal transformation, which uses measured strain and a Strain-to-Displacement Transformation (SDT) matrix to reconstruct dynamic displacement field, is proposed herein. Meanwhile, strain sensor positions are optimized by an improved Particle Swarm Optimization (PSO) algorithm to reduce systematic estimation errors of this method. Furthermore, a Back-Propagated Neutral Network (BPNN) is established to implement a self-adaptive control strategy. A series of verification tests are performed to demonstrate the validity of the proposed system. Experimental results indicate that the relative Root Mean Square Error (RMSE) between estimated vibration displacement and measured vibration displacement is less than 3%, and a vibration attenuation of over 14 dB/Hz is achieved in ground tests, proving the superiority of this intelligent active vibration suppression system.
- 22 August 2023
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 35 (1) , 68-80
An active piezoelectric damping vibration control system for the sting used in wind tunnel
In wind tunnel tests, the cantilever sting supporting system often suffers from low-frequency and large-amplitude resonance due to its inherent low structural damping characteristic, resulting in the degradation of data quality and structural safety. To improve wind tunnel testing safety and data accuracy, this paper is dedicated to establish an active vibration control system using piezoelectric stack actuators. A novel methodology of vibration monitoring based on modal transformation, which uses measured strain and a Strain-to-Displacement Transformation (SDT) matrix to reconstruct dynamic displacement field, is proposed herein. Meanwhile, strain sensor positions are optimized by an improved Particle Swarm Optimization (PSO) algorithm to reduce systematic estimation errors of this method. Furthermore, a Back-Propagated Neutral Network (BPNN) is established to implement a self-adaptive control strategy. A series of verification tests are performed to demonstrate the validity of the proposed system. Experimental results indicate that the relative Root Mean Square Error (RMSE) between estimated vibration displacement and measured vibration displacement is less than 3%, and a vibration attenuation of over 14 dB/Hz is achieved in ground tests, proving the superiority of this intelligent active vibration suppression system.