XTXiao Tang

Xiao Tang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xiao Tang has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of Automated Processes for Three-Dimensional Numerical Simulation of Compressor Performance Characteristics

    by Junbing Liu, Xiaoqiang Fan, Xiao Tang

    Compressor characteristic evaluation is a critical step in design and optimization. Corrected characteristic curves are typically derived via experimental testing or CFD computation which is typically executed through manual manipulation. For compressors necessitating extensive characteristic computation across multiple speeds and operational conditions, the involved process is inherently complex. This paper introduces an automation approach, employing dichotomy and optimization algorithms aligned with a 3D numerical solver, to streamline the derivation of compressor characteristic curves. Initially, the paper delineated the procedural frameworks for two methodologies and validated them using a single-stage transonic compressor. Both methods achieved the automated resolution of the characteristic lines. The result indicates that the volume of the iterative computations hinges on the granularity of the space searching step and the precision in identifying the stall boundary point. Pertaining to the subject investigated herein, the dichotomy method entailed fewer iterations relative to the optimization algorithm. Subsequent adjustments to the optimization algorithmic process revealed that direct optimization mitigated computational demands substantially by reducing a cycle, thereby attesting to its superior efficacy. In summary, when simulating compressor characteristic curves, the dichotomy method proves more efficient when the interval value of the stall boundary range can be approximated. Conversely, direct optimization is preferable when the estimation of the compressor’s stall boundary is imprecise. The proposed methodologies contribute to compressor research and expedite the progression of compressor development and performance advancement.

  • Open Access

    Self-Start Characteristics of Hypersonic Inlet When Multiple Unstart Modes Exist

    by Xiao Tang, Bing Xiong, Xiaoqiang Fan, Liang Wang

    Intense shock boundary-layer interaction may lead to multiple unstart modes existing in a hypersonic inlet. Thus, self-start problems become complex and cannot be explained using the classical double-solution theory of air inlet. The essence of the self-start process of a hypersonic inlet is the vanishment of separations near or in the inlet. To clarify self-start characteristics, experiments were conducted on three distinct types of unstart mode: the flow mode of small separation on body (SSB), large separation on body (LSB), and dual separations on both body and lip (DSBL); researchers recently discovered these as the unstart modes of hypersonic inlet. The results from the current experiment are as follows: (1) The SSB vanishes by raising the angle of attack (alpha). Before the vanishing point is reached, there is a dwindling process for this separation. (2) The LSB vanishes through acceleration or a decreasing alpha. (3) DSBL are difficult to vanish directly, which results in poor self-start performance. However, the DSBL flow mode may convert to LSB unstart form—which is easier to self-start—by decreasing the alpha. The Flow Field Reconstruction Method was designed to improve the self-start of the DSBL flow mode, and it was validated through experiments. Analysis of the flow mechanism revealed the reason for the poor self-start performance of the DSBL unstart mode: large-scale separation on the lip side cannot be promoted to vanish through broadwise spillage due to the resistance of sideboards. The results of this study could greatly enrich the existing theory of start problems for hypersonic inlets.