Luxi Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Luxi Zhang has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Fan Zhang
The Key Laboratory of Biomedical Engineering of Ministry of Education, Qiushi Academy for Advanced Studies, Zhejiang University, Hangzhou 310027, China
2 shared publications - Jie Xia
State Key Laboratory of Brain-Machine Intelligence, Zhejiang University, Hangzhou 311121, China
2 shared publications - Shaomin Zhang
School of Biomedical Engineering and Instrument Science, Zhejiang University
2 shared publications - Shurong Dong
Zhejiang University
2 shared publications - Gang Pan
Zhejiang University, Hangzhou, China
1 shared publication - Guodong Zhou
Zhejiang University
1 shared publication
Latest Publications
- Open Access
- 23 January 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (3) , 240
Magnetically Compatible Brain Electrode Arrays Based on Single-Walled Carbon Nanotubes for Long-Term Implantation
Advancements in brain–machine interfaces and neurological treatments urgently require the development of improved brain electrodes applied for long-term implantation, where traditional and polymer options face challenges like size, tissue damage, and signal quality. Carbon nanotubes are emerging as a promising alternative, combining excellent electronic properties and biocompatibility, which ensure better neuron coupling and stable signal acquisition. In this study, a new flexible brain electrode array based on 99.99% purity of single-walled carbon nanotubes (SWCNTs) was developed, which has 30 um × 40 um size, about 5.1 kΩ impedance, and 14.01 dB signal-to-noise ratio (SNR). The long-term implantation experiment in vivo in mice shows the proposed brain electrode can maintain stable LFP signal acquisition over 12 weeks while still achieving an SNR of 3.52 dB. The histological analysis results show that SWCNT-based brain electrodes induced minimal tissue damage and showed significantly reduced glial cell responses compared to platinum wire electrodes. Long-term stability comes from SWCNT’s biocompatibility and chemical inertness, the electrode’s flexible and fine structure. Furthermore, the new brain electrode array can function effectively during 7-Tesla magnetic resonance imaging, enabling the collection of local field potential and even epileptic discharges during the magnetic scan. This study provides a comprehensive study of carbon nanotubes as invasive brain electrodes, providing a new path to address the challenge of long-term brain electrode implantation.
- 23 January 2024
- Published by MDPI AG in Nanomaterials
- Vol. 14 (3) , 240
Open AccessMagnetically Compatible Brain Electrode Arrays Based on Single-Walled Carbon Nanotubes for Long-Term Implantation
Advancements in brain–machine interfaces and neurological treatments urgently require the development of improved brain electrodes applied for long-term implantation, where traditional and polymer options face challenges like size, tissue damage, and signal quality. Carbon nanotubes are emerging as a promising alternative, combining excellent electronic properties and biocompatibility, which ensure better neuron coupling and stable signal acquisition. In this study, a new flexible brain electrode array based on 99.99% purity of single-walled carbon nanotubes (SWCNTs) was developed, which has 30 um × 40 um size, about 5.1 kΩ impedance, and 14.01 dB signal-to-noise ratio (SNR). The long-term implantation experiment in vivo in mice shows the proposed brain electrode can maintain stable LFP signal acquisition over 12 weeks while still achieving an SNR of 3.52 dB. The histological analysis results show that SWCNT-based brain electrodes induced minimal tissue damage and showed significantly reduced glial cell responses compared to platinum wire electrodes. Long-term stability comes from SWCNT’s biocompatibility and chemical inertness, the electrode’s flexible and fine structure. Furthermore, the new brain electrode array can function effectively during 7-Tesla magnetic resonance imaging, enabling the collection of local field potential and even epileptic discharges during the magnetic scan. This study provides a comprehensive study of carbon nanotubes as invasive brain electrodes, providing a new path to address the challenge of long-term brain electrode implantation.
- Open Access
- 29 August 2023
- Published by MDPI AG in Electronics
- Vol. 12 (17) , 3648
7T Magnetic Compatible Multimodality Electrophysiological Signal Recording System
This paper developed a comprehensive magnetic resonance imaging (MRI)-compatible electrophysiological (EP) acquisition system, which can acquire various physiological electrical signals, including electrocardiography (ECG), electromyography (EMG), electroencephalography (EEG) and electrocorticogram (ECoG), and EP recording combined with multimodal stimulation. The system is designed to be compatible with the 7-Tesla (7T) ultra-high field MRI environment, providing convenience for neuroscience and physiological research. To achieve MRI compatibility, the device uses magnetically compatible materials and shielding measures on the hardware and algorithm processing on the software side. Different filtering algorithms are adopted for different signals to suppress all kinds of interference in the MRI environment. The system can allow input signals up to ±0.225 V and channels up to 256. The equipment has been tested and proven to be able to collect a variety of physiological electrical signals effectively. When scanned under the condition of a 7T high-intensity magnetic field, the system does not generate obvious heating and can meet the safety requirements of MRI and EEG acquisition requirements. Moreover, an algorithm is designed and improved to efficiently and automatically remove the gradient artifact (GA) noise generated by MRI, which is a thousand-fold gradient artifact. Overall, this work proposes a complete, portable, MRI-compatible system that can collect a variety of physiological electrical signals and integrate more efficient GA removal algorithms.
- 29 August 2023
- Published by MDPI AG in Electronics
- Vol. 12 (17) , 3648
Open Access7T Magnetic Compatible Multimodality Electrophysiological Signal Recording System
This paper developed a comprehensive magnetic resonance imaging (MRI)-compatible electrophysiological (EP) acquisition system, which can acquire various physiological electrical signals, including electrocardiography (ECG), electromyography (EMG), electroencephalography (EEG) and electrocorticogram (ECoG), and EP recording combined with multimodal stimulation. The system is designed to be compatible with the 7-Tesla (7T) ultra-high field MRI environment, providing convenience for neuroscience and physiological research. To achieve MRI compatibility, the device uses magnetically compatible materials and shielding measures on the hardware and algorithm processing on the software side. Different filtering algorithms are adopted for different signals to suppress all kinds of interference in the MRI environment. The system can allow input signals up to ±0.225 V and channels up to 256. The equipment has been tested and proven to be able to collect a variety of physiological electrical signals effectively. When scanned under the condition of a 7T high-intensity magnetic field, the system does not generate obvious heating and can meet the safety requirements of MRI and EEG acquisition requirements. Moreover, an algorithm is designed and improved to efficiently and automatically remove the gradient artifact (GA) noise generated by MRI, which is a thousand-fold gradient artifact. Overall, this work proposes a complete, portable, MRI-compatible system that can collect a variety of physiological electrical signals and integrate more efficient GA removal algorithms.