Annika Länsivaara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Annika Länsivaara has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Sami Oikarinen
Department of Virology, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
8 shared publications - Anssi Lipponen
Institute of Biomedicine, University of Eastern Finland, Kuopio, Finland
7 shared publications - Kirsi-Maarit Lehto
Tampere University
7 shared publications - Annamari Heikinheimo
Department of Food Hygiene and Environmental Health, Faculty of Veterinary Medicine, University of Helsinki, Finland
6 shared publications - Tarja Pitkänen
University of Helsinki, Faculty of Veterinary Medicine, Helsinki, Finland
6 shared publications - Rafiqul Hyder
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
5 shared publications
Latest Publications
- Open Access
- 3 May 2025
- Published by Elsevier in Environmental Research
- Vol. 279 (Pt 2) , 121776
Virus detection in influent, activated sludge, and effluent from municipal wastewater treatment plants using composite and grab samples in Finland
- 3 May 2025
- Published by Elsevier in Environmental Research
- Vol. 279 (Pt 2) , 121776
Open AccessVirus detection in influent, activated sludge, and effluent from municipal wastewater treatment plants using composite and grab samples in Finland
- Open Access
- 19 August 2024
- Published by JMIR Publications Inc. in JMIR Public Health and Surveillance
- Vol. 10 (1) , e53175
Comparison of Different Reverse Transcriptase–Polymerase Chain Reaction–Based Methods for Wastewater Surveillance of SARS-CoV-2: Exploratory Study
Background: Many countries have applied the wastewater surveillance of the COVID-19 pandemic to their national public health monitoring measures. The most used methods for detecting SARS-CoV-2 in wastewater are quantitative reverse transcriptase–polymerase chain reaction (RT-qPCR) and reverse transcriptase–droplet digital polymerase chain reaction (RT-ddPCR). Previous comparison studies have produced conflicting results, thus more research on the subject is required. Objective: This study aims to compare RT-qPCR and RT-ddPCR for detecting SARS-CoV-2 in wastewater. It also aimed to investigate the effect of changes in the analytical pipeline, including the RNA extraction kit, RT-PCR kit, and target gene assay, on the results. Another aim was to find a detection method for low-resource settings. Methods: We compared 2 RT-qPCR kits, TaqMan RT-qPCR and QuantiTect RT-qPCR, and RT-ddPCR based on sensitivity, positivity rates, variability, and correlation of SARS-CoV-2 gene copy numbers in wastewater to the incidence of COVID-19. Furthermore, we compared 2 RNA extraction methods, column- and magnetic-bead–based. In addition, we assessed 2 target gene assays for RT-qPCR, N1 and N2, and 2 target gene assays for ddPCR N1 and E. Reverse transcription strand invasion-based amplification (RT-SIBA) was used to detect SARS-CoV-2 from wastewater qualitatively. Results: Our results indicated that the most sensitive method to detect SARS-CoV-2 in wastewater was RT-ddPCR. It had the highest positivity rate (26/30), and its limit of detection was the lowest (0.06 gene copies/µL). However, we obtained the best correlation between COVID-19 incidence and SARS-CoV-2 gene copy number in wastewater using TaqMan RT-qPCR (correlation coefficient [CC]=0.697, P<.001). We found a significant difference in sensitivity between the TaqMan RT-qPCR kit and the QuantiTect RT-qPCR kit, the first having a significantly lower limit of detection and a higher positivity rate than the latter. Furthermore, the N1 target gene assay was the most sensitive for both RT-qPCR kits, while no significant difference was found between the gene targets using RT-ddPCR. In addition, the use of different RNA extraction kits affected the result when the TaqMan RT-qPCR kit was used. RT-SIBA was able to detect SARS-CoV-2 RNA in wastewater. Conclusions: As our study, as well as most of the previous studies, has shown RT-ddPCR to be more sensitive than RT-qPCR, its use in the wastewater surveillance of SARS-CoV-2 should be considered, especially if the amount of SARS-CoV-2 circulating in the population was low. All the analysis steps must be optimized for wastewater surveillance as our study showed that all the analysis steps including the compatibility of the RNA extraction, the RT-PCR kit, and the target gene assay influence the results. In addition, our study showed that RT-SIBA could be used to detect SARS-CoV-2 in wastewater if a qualitative result is sufficient.
- 19 August 2024
- Published by JMIR Publications Inc. in JMIR Public Health and Surveillance
- Vol. 10 (1) , e53175
Open AccessComparison of Different Reverse Transcriptase–Polymerase Chain Reaction–Based Methods for Wastewater Surveillance of SARS-CoV-2: Exploratory Study
Background: Many countries have applied the wastewater surveillance of the COVID-19 pandemic to their national public health monitoring measures. The most used methods for detecting SARS-CoV-2 in wastewater are quantitative reverse transcriptase–polymerase chain reaction (RT-qPCR) and reverse transcriptase–droplet digital polymerase chain reaction (RT-ddPCR). Previous comparison studies have produced conflicting results, thus more research on the subject is required. Objective: This study aims to compare RT-qPCR and RT-ddPCR for detecting SARS-CoV-2 in wastewater. It also aimed to investigate the effect of changes in the analytical pipeline, including the RNA extraction kit, RT-PCR kit, and target gene assay, on the results. Another aim was to find a detection method for low-resource settings. Methods: We compared 2 RT-qPCR kits, TaqMan RT-qPCR and QuantiTect RT-qPCR, and RT-ddPCR based on sensitivity, positivity rates, variability, and correlation of SARS-CoV-2 gene copy numbers in wastewater to the incidence of COVID-19. Furthermore, we compared 2 RNA extraction methods, column- and magnetic-bead–based. In addition, we assessed 2 target gene assays for RT-qPCR, N1 and N2, and 2 target gene assays for ddPCR N1 and E. Reverse transcription strand invasion-based amplification (RT-SIBA) was used to detect SARS-CoV-2 from wastewater qualitatively. Results: Our results indicated that the most sensitive method to detect SARS-CoV-2 in wastewater was RT-ddPCR. It had the highest positivity rate (26/30), and its limit of detection was the lowest (0.06 gene copies/µL). However, we obtained the best correlation between COVID-19 incidence and SARS-CoV-2 gene copy number in wastewater using TaqMan RT-qPCR (correlation coefficient [CC]=0.697, P<.001). We found a significant difference in sensitivity between the TaqMan RT-qPCR kit and the QuantiTect RT-qPCR kit, the first having a significantly lower limit of detection and a higher positivity rate than the latter. Furthermore, the N1 target gene assay was the most sensitive for both RT-qPCR kits, while no significant difference was found between the gene targets using RT-ddPCR. In addition, the use of different RNA extraction kits affected the result when the TaqMan RT-qPCR kit was used. RT-SIBA was able to detect SARS-CoV-2 RNA in wastewater. Conclusions: As our study, as well as most of the previous studies, has shown RT-ddPCR to be more sensitive than RT-qPCR, its use in the wastewater surveillance of SARS-CoV-2 should be considered, especially if the amount of SARS-CoV-2 circulating in the population was low. All the analysis steps must be optimized for wastewater surveillance as our study showed that all the analysis steps including the compatibility of the RNA extraction, the RT-PCR kit, and the target gene assay influence the results. In addition, our study showed that RT-SIBA could be used to detect SARS-CoV-2 in wastewater if a qualitative result is sufficient.
- Open Access
- 9 May 2024
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 4 (6) , 2403-2411
Wastewater-Based Surveillance of Respiratory Syncytial Virus Epidemic at the National Level in Finland
- 9 May 2024
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 4 (6) , 2403-2411
Open AccessWastewater-Based Surveillance of Respiratory Syncytial Virus Epidemic at the National Level in Finland
- Open Access
- 11 March 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 926, 171401
Developing wastewater-based surveillance schemes for multiple pathogens: The WastPan project in Finland
- 11 March 2024
- Published by Elsevier in Science of The Total Environment
- Vol. 926, 171401
Open AccessDeveloping wastewater-based surveillance schemes for multiple pathogens: The WastPan project in Finland
- Open Access
- 28 September 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Comparison of Different Reverse Transcriptase–Polymerase Chain Reaction–Based Methods for Wastewater Surveillance of SARS-CoV-2: Exploratory Study (Preprint)
BACKGROUND Many countries have applied the wastewater surveillance of the COVID-19 pandemic to their national public health monitoring measures. The most used methods for detecting SARS-CoV-2 in wastewater are quantitative reverse transcriptase–polymerase chain reaction (RT-qPCR) and reverse transcriptase–droplet digital polymerase chain reaction (RT-ddPCR). Previous comparison studies have produced conflicting results, thus more research on the subject is required. OBJECTIVE This study aims to compare RT-qPCR and RT-ddPCR for detecting SARS-CoV-2 in wastewater. It also aimed to investigate the effect of changes in the analytical pipeline, including the RNA extraction kit, RT-PCR kit, and target gene assay, on the results. Another aim was to find a detection method for low-resource settings. METHODS We compared 2 RT-qPCR kits, TaqMan RT-qPCR and QuantiTect RT-qPCR, and RT-ddPCR based on sensitivity, positivity rates, variability, and correlation of SARS-CoV-2 gene copy numbers in wastewater to the incidence of COVID-19. Furthermore, we compared 2 RNA extraction methods, column- and magnetic-bead–based. In addition, we assessed 2 target gene assays for RT-qPCR, N1 and N2, and 2 target gene assays for ddPCR N1 and E. Reverse transcription strand invasion-based amplification (RT-SIBA) was used to detect SARS-CoV-2 from wastewater qualitatively. RESULTS Our results indicated that the most sensitive method to detect SARS-CoV-2 in wastewater was RT-ddPCR. It had the highest positivity rate (26/30), and its limit of detection was the lowest (0.06 gene copies/µL). However, we obtained the best correlation between COVID-19 incidence and SARS-CoV-2 gene copy number in wastewater using TaqMan RT-qPCR (correlation coefficient [CC]=0.697, P<.001). We found a significant difference in sensitivity between the TaqMan RT-qPCR kit and the QuantiTect RT-qPCR kit, the first having a significantly lower limit of detection and a higher positivity rate than the latter. Furthermore, the N1 target gene assay was the most sensitive for both RT-qPCR kits, while no significant difference was found between the gene targets using RT-ddPCR. In addition, the use of different RNA extraction kits affected the result when the TaqMan RT-qPCR kit was used. RT-SIBA was able to detect SARS-CoV-2 RNA in wastewater. CONCLUSIONS As our study, as well as most of the previous studies, has shown RT-ddPCR to be more sensitive than RT-qPCR, its use in the wastewater surveillance of SARS-CoV-2 should be considered, especially if the amount of SARS-CoV-2 circulating in the population was low. All the analysis steps must be optimized for wastewater surveillance as our study showed that all the analysis steps including the compatibility of the RNA extraction, the RT-PCR kit, and the target gene assay influence the results. In addition, our study showed that RT-SIBA could be used to detect SARS-CoV-2 in wastewater if a qualitative result is sufficient.
- 28 September 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessComparison of Different Reverse Transcriptase–Polymerase Chain Reaction–Based Methods for Wastewater Surveillance of SARS-CoV-2: Exploratory Study (Preprint)
BACKGROUND Many countries have applied the wastewater surveillance of the COVID-19 pandemic to their national public health monitoring measures. The most used methods for detecting SARS-CoV-2 in wastewater are quantitative reverse transcriptase–polymerase chain reaction (RT-qPCR) and reverse transcriptase–droplet digital polymerase chain reaction (RT-ddPCR). Previous comparison studies have produced conflicting results, thus more research on the subject is required. OBJECTIVE This study aims to compare RT-qPCR and RT-ddPCR for detecting SARS-CoV-2 in wastewater. It also aimed to investigate the effect of changes in the analytical pipeline, including the RNA extraction kit, RT-PCR kit, and target gene assay, on the results. Another aim was to find a detection method for low-resource settings. METHODS We compared 2 RT-qPCR kits, TaqMan RT-qPCR and QuantiTect RT-qPCR, and RT-ddPCR based on sensitivity, positivity rates, variability, and correlation of SARS-CoV-2 gene copy numbers in wastewater to the incidence of COVID-19. Furthermore, we compared 2 RNA extraction methods, column- and magnetic-bead–based. In addition, we assessed 2 target gene assays for RT-qPCR, N1 and N2, and 2 target gene assays for ddPCR N1 and E. Reverse transcription strand invasion-based amplification (RT-SIBA) was used to detect SARS-CoV-2 from wastewater qualitatively. RESULTS Our results indicated that the most sensitive method to detect SARS-CoV-2 in wastewater was RT-ddPCR. It had the highest positivity rate (26/30), and its limit of detection was the lowest (0.06 gene copies/µL). However, we obtained the best correlation between COVID-19 incidence and SARS-CoV-2 gene copy number in wastewater using TaqMan RT-qPCR (correlation coefficient [CC]=0.697, P<.001). We found a significant difference in sensitivity between the TaqMan RT-qPCR kit and the QuantiTect RT-qPCR kit, the first having a significantly lower limit of detection and a higher positivity rate than the latter. Furthermore, the N1 target gene assay was the most sensitive for both RT-qPCR kits, while no significant difference was found between the gene targets using RT-ddPCR. In addition, the use of different RNA extraction kits affected the result when the TaqMan RT-qPCR kit was used. RT-SIBA was able to detect SARS-CoV-2 RNA in wastewater. CONCLUSIONS As our study, as well as most of the previous studies, has shown RT-ddPCR to be more sensitive than RT-qPCR, its use in the wastewater surveillance of SARS-CoV-2 should be considered, especially if the amount of SARS-CoV-2 circulating in the population was low. All the analysis steps must be optimized for wastewater surveillance as our study showed that all the analysis steps including the compatibility of the RNA extraction, the RT-PCR kit, and the target gene assay influence the results. In addition, our study showed that RT-SIBA could be used to detect SARS-CoV-2 in wastewater if a qualitative result is sufficient.
- Open Access
Comparison of Different PCR Methods for the Detection of SARS-CoV-2 RNA in Wastewater Based on the Reported Incidence of COVID-19 in Finland
The spatial and temporal changes of the COVID-19 pandemic have been monitored with wastewater-based surveillance, which many countries have applied to their national public health monitoring measures. The most commonly used methods for the detection of SARS-CoV-2 in wastewater are RT-qPCR and RT-ddPCR. Previous comparisons of the two methods have produced conflicting results; some found RT-ddPCR to be more sensitive, one found RT-qPCR to be more sensitive, and others found them to be equal in sensitivity. This research was conducted to further study these two methods as well as two different RNA extraction methodologies and gene assays for the detection of SARS-CoV-2 in wastewater. We compared two RT-qPCR kits and RT-ddPCR based on sensitivity, variability, and the correlation of SARS-CoV-2 gene copy numbers in wastewater with the incidence of COVID-19. Our results indicate that the most sensitive and low-variance method to detect SARS-CoV-2 in wastewater was RT-ddPCR. However, we obtained the best correlation between COVID-19 incidence and SARS-CoV-2 gene copy number in wastewater using RT-qPCR (CC = 0.697, p < 0.001). We found a significant difference in sensitivity between the two RT-qPCR kits, one having a significantly lower limit of detection and a higher percentage of positive samples than the other. Furthermore, the CDC N1 primers and probe were the most sensitive for both RT-qPCR kits, while there was no significant difference between the tested gene targets using RT-ddPCR. For the most sensitive RT-qPCR, the use of different RNA extraction kits affected the result. All methods showed a trend between COVID-19 incidence and SARS-CoV-2 gene copy numbers in wastewater. In addition, we tested an isothermal amplification method for the detection of SARS-CoV-2 RNA in wastewater. It proved to be a viable option if results are expected quickly, resources are limited, and presence–absence information is sufficient. Highlights Using different RNA extraction kits, detection kits, and gene assays to detect SARS-CoV-2 in wastewater produces differing results. SARS-CoV-2 gene copies in wastewater correlate with the reported incidence of COVID-19 in Finland. RT-ddPCR was the most sensitive and repeatable method to detect SARS-CoV-2 in wastewater, whereas RT-qPCR had the best correlation to the incidence of COVID-19. RT-SIBA is a viable option for the detection of SARS-CoV-2 in wastewater in low-resource settings. All methods have high result variability when the amount of SARS-CoV-2 in wastewater is low. Created with BioRender.com
Open AccessComparison of Different PCR Methods for the Detection of SARS-CoV-2 RNA in Wastewater Based on the Reported Incidence of COVID-19 in Finland
The spatial and temporal changes of the COVID-19 pandemic have been monitored with wastewater-based surveillance, which many countries have applied to their national public health monitoring measures. The most commonly used methods for the detection of SARS-CoV-2 in wastewater are RT-qPCR and RT-ddPCR. Previous comparisons of the two methods have produced conflicting results; some found RT-ddPCR to be more sensitive, one found RT-qPCR to be more sensitive, and others found them to be equal in sensitivity. This research was conducted to further study these two methods as well as two different RNA extraction methodologies and gene assays for the detection of SARS-CoV-2 in wastewater. We compared two RT-qPCR kits and RT-ddPCR based on sensitivity, variability, and the correlation of SARS-CoV-2 gene copy numbers in wastewater with the incidence of COVID-19. Our results indicate that the most sensitive and low-variance method to detect SARS-CoV-2 in wastewater was RT-ddPCR. However, we obtained the best correlation between COVID-19 incidence and SARS-CoV-2 gene copy number in wastewater using RT-qPCR (CC = 0.697, p < 0.001). We found a significant difference in sensitivity between the two RT-qPCR kits, one having a significantly lower limit of detection and a higher percentage of positive samples than the other. Furthermore, the CDC N1 primers and probe were the most sensitive for both RT-qPCR kits, while there was no significant difference between the tested gene targets using RT-ddPCR. For the most sensitive RT-qPCR, the use of different RNA extraction kits affected the result. All methods showed a trend between COVID-19 incidence and SARS-CoV-2 gene copy numbers in wastewater. In addition, we tested an isothermal amplification method for the detection of SARS-CoV-2 RNA in wastewater. It proved to be a viable option if results are expected quickly, resources are limited, and presence–absence information is sufficient. Highlights Using different RNA extraction kits, detection kits, and gene assays to detect SARS-CoV-2 in wastewater produces differing results. SARS-CoV-2 gene copies in wastewater correlate with the reported incidence of COVID-19 in Finland. RT-ddPCR was the most sensitive and repeatable method to detect SARS-CoV-2 in wastewater, whereas RT-qPCR had the best correlation to the incidence of COVID-19. RT-SIBA is a viable option for the detection of SARS-CoV-2 in wastewater in low-resource settings. All methods have high result variability when the amount of SARS-CoV-2 in wastewater is low. Created with BioRender.com
- Open Access
Wastewater-based surveillance of respiratory syncytial virus epidemic at the national level in Finland
The purpose of this study was to evaluate the potential of wastewater-based surveillance in the monitoring of epidemics at the national level in Finland. To discover the correlation of wastewater data and register data, the 2021–2022 respiratory syncytial virus (RSV) epidemic in Finland was analyzed from wastewater and the Finnish National Infectious Diseases Register. The study was performed using samples that were collected monthly from May 2021 to July 2022 from ten wastewater treatment plants that cover 40% of the Finnish population. Respiratory syncytial virus detection in 24-h composite samples of influent wastewater was performed using RT-qPCR. Respiratory syncytial virus wastewater data were positively correlated with the National Infectious Diseases Register data for the sampling week (correlation coefficient, CC min = 0.412, max = 0.865). Furthermore, the cumulative incidence of respiratory syncytial virus from the sampling week to three weeks afterward was strongly correlated with the wastewater data (CC min = 0.482, max = 0.814), showing the potential of wastewater-based surveillance for use in estimating the course of the epidemic. When the register-based incidence of RSV was at least four cases/100,000 persons/week in the sampling week, it was detected in all wastewater samples. This study showed that wastewater surveillance is useful in the surveillance of respiratory syncytial virus epidemics, and its potential in the surveillance of other epidemics should be explored further. Synopsis Environmental surveillance has been previously used to monitor viruses such as poliovirus and SARS-CoV-2. This study shows that wastewater-based surveillance can be used to surveil the respiratory syncytial virus and its epidemics, at a national level.
Open AccessWastewater-based surveillance of respiratory syncytial virus epidemic at the national level in Finland
The purpose of this study was to evaluate the potential of wastewater-based surveillance in the monitoring of epidemics at the national level in Finland. To discover the correlation of wastewater data and register data, the 2021–2022 respiratory syncytial virus (RSV) epidemic in Finland was analyzed from wastewater and the Finnish National Infectious Diseases Register. The study was performed using samples that were collected monthly from May 2021 to July 2022 from ten wastewater treatment plants that cover 40% of the Finnish population. Respiratory syncytial virus detection in 24-h composite samples of influent wastewater was performed using RT-qPCR. Respiratory syncytial virus wastewater data were positively correlated with the National Infectious Diseases Register data for the sampling week (correlation coefficient, CC min = 0.412, max = 0.865). Furthermore, the cumulative incidence of respiratory syncytial virus from the sampling week to three weeks afterward was strongly correlated with the wastewater data (CC min = 0.482, max = 0.814), showing the potential of wastewater-based surveillance for use in estimating the course of the epidemic. When the register-based incidence of RSV was at least four cases/100,000 persons/week in the sampling week, it was detected in all wastewater samples. This study showed that wastewater surveillance is useful in the surveillance of respiratory syncytial virus epidemics, and its potential in the surveillance of other epidemics should be explored further. Synopsis Environmental surveillance has been previously used to monitor viruses such as poliovirus and SARS-CoV-2. This study shows that wastewater-based surveillance can be used to surveil the respiratory syncytial virus and its epidemics, at a national level.
- Open Access
Wastewater-based surveillance is an efficient monitoring tool for tracking influenza A virus in the community
Around the world, influenza A virus has caused severe pandemics, and the risk of future pandemics remains high. Currently, influenza A virus surveillance is based on the clinical diagnosis and reporting of disease cases. In this study, we apply wastewater-based surveillance to monitor the incidence of the influenza A virus at the population level. We report incidence data of the influenza A virus in 10 wastewater treatment plant catchment areas covering 40% of the Finnish population. Altogether, 141 monthly composite influent wastewater samples (collected between April 2020 and May 2021) were analysed from supernatant fraction using influenza A virus specific RT-qPCR method. During the study period, an influenza A virus epidemic occurred in two waves in Finland. This study shows that the influenza A virus can be detected from the supernatant fraction of 24 h composite influent wastewater samples. The influenza A virus gene copy number in wastewater correlated with the number of confirmed disease cases in the Finnish National Infectious Diseases Register. The Kendall’s τ correlation strength was over 0.600 in all wastewater treatment plants, save for one, which was 0.459. The strongest correlations were 0.761 and 0.833. Wastewater-based surveillance of the influenza A virus is an unbiased method and cost-efficiently reflects the circulation of the virus in the entire population. Thus, wastewater monitoring complements the available, but often too sparse, information from individual testing and improves health care and public health preparedness for influenza A virus pandemics.
Open AccessWastewater-based surveillance is an efficient monitoring tool for tracking influenza A virus in the community
Around the world, influenza A virus has caused severe pandemics, and the risk of future pandemics remains high. Currently, influenza A virus surveillance is based on the clinical diagnosis and reporting of disease cases. In this study, we apply wastewater-based surveillance to monitor the incidence of the influenza A virus at the population level. We report incidence data of the influenza A virus in 10 wastewater treatment plant catchment areas covering 40% of the Finnish population. Altogether, 141 monthly composite influent wastewater samples (collected between April 2020 and May 2021) were analysed from supernatant fraction using influenza A virus specific RT-qPCR method. During the study period, an influenza A virus epidemic occurred in two waves in Finland. This study shows that the influenza A virus can be detected from the supernatant fraction of 24 h composite influent wastewater samples. The influenza A virus gene copy number in wastewater correlated with the number of confirmed disease cases in the Finnish National Infectious Diseases Register. The Kendall’s τ correlation strength was over 0.600 in all wastewater treatment plants, save for one, which was 0.459. The strongest correlations were 0.761 and 0.833. Wastewater-based surveillance of the influenza A virus is an unbiased method and cost-efficiently reflects the circulation of the virus in the entire population. Thus, wastewater monitoring complements the available, but often too sparse, information from individual testing and improves health care and public health preparedness for influenza A virus pandemics.