Zhixuan Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhixuan Li has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Ying Xue
School of Electric Power Engineering, South China University of Technology, Guangzhou, China
9 shared publications - Conghuan Yang
Guangzhou Maritime University, Guangzhou, China
5 shared publications - Yiping Chen
Power Dispatching and Control Center, China Southern Power Grid, Guangzhou, China
5 shared publications - Nan Chen
Department of Electronic, Electrical and Systems Engineering, School of Engineering, University of Birmingham, Birmingham, U.K.
3 shared publications - Siqi Lin
School of Electric Power Engineering, South China University of Technology, Guangzhou, China
3 shared publications Waisheng Zheng
China Southern Power Grid Electric Power Research Institute Company Ltd., Guangzhou, China
3 shared publications
Latest Publications
- Open Access
Primary Frequency Control of Hybrid LCC–MMC HVDC Systems with Dual-Port Grid-Forming MMC Control for Renewable-Rich Power Systems
Frequency stability is becoming an increasingly critical issue in asynchronously interconnected (ASI) power systems, where DC interconnections inherently decouple frequency dynamics between asynchronous AC grids and conventional synchronous generators are progressively displaced by renewable energy resources with limited frequency-support capability. To address this issue, this paper proposes a primary frequency control strategy for a hybrid High Voltage Direct Current (HVDC) system composed of a line-commutated converter (LCC) rectifier and a modular multilevel converter (MMC) inverter. In the proposed scheme, the MMC adopts a dual-port grid-forming (GFM) control mode, thereby establishing voltage-source characteristics at both its AC and DC ports, while the LCC rectifier regulates the DC current. Through the interaction between the DC-voltage-forming MMC and the DC-current-regulating LCC, bilateral primary frequency support can be achieved for the two asynchronous AC systems without requiring frequency-signal communication between the converters. Furthermore, a frequency-response model is developed to characterize the frequency-coupling dynamics of the ASI system and to quantify the frequency-support capability enabled by the proposed control. Based on this model, the parameterization of the proposed frequency control is further discussed. Finally, real-time digital simulation studies are carried out on an RTDS platform to validate the effectiveness of the proposed control strategy and the accuracy of the developed analytical model.
Open AccessPrimary Frequency Control of Hybrid LCC–MMC HVDC Systems with Dual-Port Grid-Forming MMC Control for Renewable-Rich Power Systems
Frequency stability is becoming an increasingly critical issue in asynchronously interconnected (ASI) power systems, where DC interconnections inherently decouple frequency dynamics between asynchronous AC grids and conventional synchronous generators are progressively displaced by renewable energy resources with limited frequency-support capability. To address this issue, this paper proposes a primary frequency control strategy for a hybrid High Voltage Direct Current (HVDC) system composed of a line-commutated converter (LCC) rectifier and a modular multilevel converter (MMC) inverter. In the proposed scheme, the MMC adopts a dual-port grid-forming (GFM) control mode, thereby establishing voltage-source characteristics at both its AC and DC ports, while the LCC rectifier regulates the DC current. Through the interaction between the DC-voltage-forming MMC and the DC-current-regulating LCC, bilateral primary frequency support can be achieved for the two asynchronous AC systems without requiring frequency-signal communication between the converters. Furthermore, a frequency-response model is developed to characterize the frequency-coupling dynamics of the ASI system and to quantify the frequency-support capability enabled by the proposed control. Based on this model, the parameterization of the proposed frequency control is further discussed. Finally, real-time digital simulation studies are carried out on an RTDS platform to validate the effectiveness of the proposed control strategy and the accuracy of the developed analytical model.
- 16 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 152
Mitigation of commutation failures in LCC-HVDC systems during post-fault recovery using adaptive extinction angle and DC current control
- 16 February 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108 (3) , 152
Mitigation of commutation failures in LCC-HVDC systems during post-fault recovery using adaptive extinction angle and DC current control
- Open Access
- 22 October 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Power reversal strategy through DC current reversal using a new bidirectional LCC HVDC system
- 22 October 2025
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 172
Open AccessPower reversal strategy through DC current reversal using a new bidirectional LCC HVDC system
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (1) , 484-498
Adaptive AC Voltage Control Using LCC-HVDC Based on Linearized Reactive Power-AC Voltage Characteristic
Sourcing voltage support from LCC-HVDC is a promising solution for enhancing transmission-level voltage stability. Existing methods contribute to this effort when Thevenin equivalent parameters (TEPs) are available; however, obtaining TEPs requires precise real-time measurements and AC grid modeling. In this paper, an adaptive AC voltage control (A2VC) is proposed to address the challenge of deriving TEPs. Emphasis is put on a linear grid model (LGM) that views the AC grid through a linearized reactive power-AC voltage (Q-V) port characteristic, which results in a locally defined AC grid model that is independent of TEPs. The local LGM is then integrated into the LCC-HVDC control system as an outer loop, enabling the LCC to adjust reactive power in response to AC voltage variations. Compared to existing methods, the proposed method retains simplicity, robustness and adaptability, making it applicable to various grid configurations and conditions. The EMT simulation is used to evaluate the performance of the proposed LGM and A 2VC in both small and large grids. The results reveal a highly linear Q-V characteristic, with the coefficient of determination (R2) exceeding 0.9, as well as a notably reduced AC overvoltage under both reactive disturbances and fault conditions.
- 14 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 41 (1) , 484-498
Adaptive AC Voltage Control Using LCC-HVDC Based on Linearized Reactive Power-AC Voltage Characteristic
Sourcing voltage support from LCC-HVDC is a promising solution for enhancing transmission-level voltage stability. Existing methods contribute to this effort when Thevenin equivalent parameters (TEPs) are available; however, obtaining TEPs requires precise real-time measurements and AC grid modeling. In this paper, an adaptive AC voltage control (A2VC) is proposed to address the challenge of deriving TEPs. Emphasis is put on a linear grid model (LGM) that views the AC grid through a linearized reactive power-AC voltage (Q-V) port characteristic, which results in a locally defined AC grid model that is independent of TEPs. The local LGM is then integrated into the LCC-HVDC control system as an outer loop, enabling the LCC to adjust reactive power in response to AC voltage variations. Compared to existing methods, the proposed method retains simplicity, robustness and adaptability, making it applicable to various grid configurations and conditions. The EMT simulation is used to evaluate the performance of the proposed LGM and A 2VC in both small and large grids. The results reveal a highly linear Q-V characteristic, with the coefficient of determination (R2) exceeding 0.9, as well as a notably reduced AC overvoltage under both reactive disturbances and fault conditions.
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (6) , 5446-5458
Low-Frequency Power Oscillations in DC Systems for Asynchronous Interconnection: Insights From the LUXI Back-to-Back HVDC Project
The Voltage Source Converter based High Voltage Direct Current (VSC-HVDC) system is considered an efficient solution for providing functional support to asynchronously interconnected systems. However, this study demonstrates that frequency support from VSC-HVDC systems can lead to low-frequency power oscillations (LFPOs) due to the interaction between the frequency control and the frequency dynamics of AC grids. For convenience, a practical instance of a 0.25 Hz LFPO observed in the LUXI back-to-back VSC-HVDC project in the China is reported in detail. In this project, the VSC-HVDC system is designed with a frequency control (namely, Co-frequency control) to eliminate frequency divisions between the two asynchronous AC grids under normal operation conditions. Based on the damping torque method, the analysis concludes that the observed LFPO is induced by the interaction between the Co-frequency control and the frequency dynamics of the synchronous generators in AC systems, and is governed by the parameters of the Co-frequency control. To address the LFPO, two damping control schemes are proposed. Finally, all conclusions and findings are validated through EMT simulations. To the best of our knowledge, this is the first report of practical oscillations caused by the frequency control of VSC-HVDC systems, which is meaningful for engineers and researchers, by providing insights about the stable operation of asynchronously interconnected systems.
- 4 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (6) , 5446-5458
Low-Frequency Power Oscillations in DC Systems for Asynchronous Interconnection: Insights From the LUXI Back-to-Back HVDC Project
The Voltage Source Converter based High Voltage Direct Current (VSC-HVDC) system is considered an efficient solution for providing functional support to asynchronously interconnected systems. However, this study demonstrates that frequency support from VSC-HVDC systems can lead to low-frequency power oscillations (LFPOs) due to the interaction between the frequency control and the frequency dynamics of AC grids. For convenience, a practical instance of a 0.25 Hz LFPO observed in the LUXI back-to-back VSC-HVDC project in the China is reported in detail. In this project, the VSC-HVDC system is designed with a frequency control (namely, Co-frequency control) to eliminate frequency divisions between the two asynchronous AC grids under normal operation conditions. Based on the damping torque method, the analysis concludes that the observed LFPO is induced by the interaction between the Co-frequency control and the frequency dynamics of the synchronous generators in AC systems, and is governed by the parameters of the Co-frequency control. To address the LFPO, two damping control schemes are proposed. Finally, all conclusions and findings are validated through EMT simulations. To the best of our knowledge, this is the first report of practical oscillations caused by the frequency control of VSC-HVDC systems, which is meaningful for engineers and researchers, by providing insights about the stable operation of asynchronously interconnected systems.
- Open Access
Investigation of Frequency Response Sharing-Induced Power Oscillations in VSC-HVDC Systems for Asynchronous Interconnection
Low-frequency power oscillations (LFPOs) may occur in voltage source converter-based high-voltage direct current (VSC-HVDC) systems when providing frequency support to asynchronously interconnected power grids. This phenomenon has been observed in the LUXI back-to-back (BTB) VSC-HVDC project in China and results from insufficient damping, which may threaten the stability of the overall power system. To better understand and address this problem, this study investigates the root causes of LFPOs and evaluates how different parts of the system affect damping. A combined approach using small-signal modeling and the damping torque method is developed to analyze the damping behavior of DC power in VSC-HVDC systems. Results show that LFPOs are caused by the interaction between VSC-based frequency control and the dynamic response of synchronous generators (SGs). The turbine and governor systems in SGs help stabilize the system by providing positive damping, whereas the DC voltage-controlled VSC station introduces negative damping. The findings are supported by detailed simulations using a modified IEEE 39-bus test system, demonstrating the effectiveness of the proposed analysis method.
Open AccessInvestigation of Frequency Response Sharing-Induced Power Oscillations in VSC-HVDC Systems for Asynchronous Interconnection
Low-frequency power oscillations (LFPOs) may occur in voltage source converter-based high-voltage direct current (VSC-HVDC) systems when providing frequency support to asynchronously interconnected power grids. This phenomenon has been observed in the LUXI back-to-back (BTB) VSC-HVDC project in China and results from insufficient damping, which may threaten the stability of the overall power system. To better understand and address this problem, this study investigates the root causes of LFPOs and evaluates how different parts of the system affect damping. A combined approach using small-signal modeling and the damping torque method is developed to analyze the damping behavior of DC power in VSC-HVDC systems. Results show that LFPOs are caused by the interaction between VSC-based frequency control and the dynamic response of synchronous generators (SGs). The turbine and governor systems in SGs help stabilize the system by providing positive damping, whereas the DC voltage-controlled VSC station introduces negative damping. The findings are supported by detailed simulations using a modified IEEE 39-bus test system, demonstrating the effectiveness of the proposed analysis method.
- 8 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (6) , 5221-5236
Generic Low-Order Primary Frequency Response Model for Frequency Nadir Prediction
The frequency nadir (FN) is a crucial indicator for frequency stability. Accurate FN estimation helps operators assess stability risks and determine the required Primary Frequency Response (PFR) reserves. Existing analytical methods for FN estimation face problems such as poor applicability, inability to be numerically solved for FN, and a lack of analysis of the governor-turbine model needed to establish a low-order PFR model. This paper employs adaptable low-order fitting approaches to the governor-turbine model to propose a generic low-order PFR model. This model is applicable to various governor-turbine systems and scenarios where converter-based systems participate in PFR. Its low-order characteristic enables efficient numerical calculation of FN and quantitative tuning of control parameters for converter-based systems. To demonstrate the accuracy and applicability of the proposed method, case studies for FN prediction are carried out on the IEEE 9/39 bus systems, and parameter tuning for the High Voltage Direct Current (HVDC) system is presented when the HVDC provides frequency support to the AC system.
- 8 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (6) , 5221-5236
Generic Low-Order Primary Frequency Response Model for Frequency Nadir Prediction
The frequency nadir (FN) is a crucial indicator for frequency stability. Accurate FN estimation helps operators assess stability risks and determine the required Primary Frequency Response (PFR) reserves. Existing analytical methods for FN estimation face problems such as poor applicability, inability to be numerically solved for FN, and a lack of analysis of the governor-turbine model needed to establish a low-order PFR model. This paper employs adaptable low-order fitting approaches to the governor-turbine model to propose a generic low-order PFR model. This model is applicable to various governor-turbine systems and scenarios where converter-based systems participate in PFR. Its low-order characteristic enables efficient numerical calculation of FN and quantitative tuning of control parameters for converter-based systems. To demonstrate the accuracy and applicability of the proposed method, case studies for FN prediction are carried out on the IEEE 9/39 bus systems, and parameter tuning for the High Voltage Direct Current (HVDC) system is presented when the HVDC provides frequency support to the AC system.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (3) , 2600-2612
Bilateral Primary Frequency Support and AC Voltage Regulation of LCC-HVDC Systems for Asynchronously Interconnected Systems
Modern power systems require significant grid flexibility. As the AC transmission lines are passive and cannot be controlled, grid flexibility in the transmission system can only be provided by actively controlling High-Voltage Direct Current (HVDC) systems, particularly the dominant LCC-HVDC systems. Although grid-flexibility support using LCC-HVDC has been studied, existing methods fail to achieve bidirectional frequency support while maintaining AC voltage. Therefore, a coordinated control method is proposed for the LCC-HVDC system to achieve bilateral frequency support (BFS) and AC voltage regulation (AVR) for asynchronously interconnected systems. The level of frequency support and the coupled dynamics of sending-end (SE) and receiving-end (RE) system frequencies are quantified by the developed low-order frequency response model, different from frequency models in previous research for only one end of the system. With the developed model, the control parameters of the proposed method are analytically calculated. This ensures an appropriate level of primary frequency support without jeopardizing the frequency response of the system at the remote end. The effectiveness of the proposed method is demonstrated through real-time simulation.
- 13 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 40 (3) , 2600-2612
Bilateral Primary Frequency Support and AC Voltage Regulation of LCC-HVDC Systems for Asynchronously Interconnected Systems
Modern power systems require significant grid flexibility. As the AC transmission lines are passive and cannot be controlled, grid flexibility in the transmission system can only be provided by actively controlling High-Voltage Direct Current (HVDC) systems, particularly the dominant LCC-HVDC systems. Although grid-flexibility support using LCC-HVDC has been studied, existing methods fail to achieve bidirectional frequency support while maintaining AC voltage. Therefore, a coordinated control method is proposed for the LCC-HVDC system to achieve bilateral frequency support (BFS) and AC voltage regulation (AVR) for asynchronously interconnected systems. The level of frequency support and the coupled dynamics of sending-end (SE) and receiving-end (RE) system frequencies are quantified by the developed low-order frequency response model, different from frequency models in previous research for only one end of the system. With the developed model, the control parameters of the proposed method are analytically calculated. This ensures an appropriate level of primary frequency support without jeopardizing the frequency response of the system at the remote end. The effectiveness of the proposed method is demonstrated through real-time simulation.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (1) , 126-138
Estimating Phase Angle Jump of Commutation Voltage and Suppressing Commutation Failure During Fault Recovery
The phase angle jump (PAJ) of the commutation voltage during fault is well-known to have significant impact on the commutation failure during fault recovery (CFFR) in line-commutated converter-based high voltage direct current (LCC-HVDC). However, the value of PAJ has been empirically determined in previous research without a theoretical foundation, leading to inaccurate estimation of its impact on CFFR and inappropriate control actions to mitigate CFFR. To address this issue, this paper theoretically shows how the Network Structure (NS) in different AC systems changes the level of PAJ of commutation voltage, demonstrating the decisive role of changing NS in evaluating CFFR. Specifically, a calculation method based on equivalent AC-DC system (EADSC) is proposed, showing that transient NS changes (TNSC) and transient DC power flow changes (TDPC) jointly contribute to the level of PAJ. Based on these findings, a PAJ-based firing angle compensation strategy (PAJ-ACS) is proposed for CFFR suppression. PAJ-ACS compensates for tracking error of the phase-locked loop (PLL-TE) caused by TNSC and TDPC, and prevents the saturation of the constant extinction angle controller (CEA) by using adaptive extinction angle reference values. Unlike existing methods, PAJ-ACS is designed based on proportional controllers and considers the most extreme PAJ, enabling rapid and targeted compensation with margin, effectively suppressing CFFR under a wide range of fault conditions. The accuracy of the proposed EADSC and the effectiveness of PAJ-ACS are validated using PSCAD/EMTDC simulations on the modified CIGRE LCC-HVDC benchmark system and the IEEE 39-bus system.
- 24 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (1) , 126-138
Estimating Phase Angle Jump of Commutation Voltage and Suppressing Commutation Failure During Fault Recovery
The phase angle jump (PAJ) of the commutation voltage during fault is well-known to have significant impact on the commutation failure during fault recovery (CFFR) in line-commutated converter-based high voltage direct current (LCC-HVDC). However, the value of PAJ has been empirically determined in previous research without a theoretical foundation, leading to inaccurate estimation of its impact on CFFR and inappropriate control actions to mitigate CFFR. To address this issue, this paper theoretically shows how the Network Structure (NS) in different AC systems changes the level of PAJ of commutation voltage, demonstrating the decisive role of changing NS in evaluating CFFR. Specifically, a calculation method based on equivalent AC-DC system (EADSC) is proposed, showing that transient NS changes (TNSC) and transient DC power flow changes (TDPC) jointly contribute to the level of PAJ. Based on these findings, a PAJ-based firing angle compensation strategy (PAJ-ACS) is proposed for CFFR suppression. PAJ-ACS compensates for tracking error of the phase-locked loop (PLL-TE) caused by TNSC and TDPC, and prevents the saturation of the constant extinction angle controller (CEA) by using adaptive extinction angle reference values. Unlike existing methods, PAJ-ACS is designed based on proportional controllers and considers the most extreme PAJ, enabling rapid and targeted compensation with margin, effectively suppressing CFFR under a wide range of fault conditions. The accuracy of the proposed EADSC and the effectiveness of PAJ-ACS are validated using PSCAD/EMTDC simulations on the modified CIGRE LCC-HVDC benchmark system and the IEEE 39-bus system.