Alain Savary
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alain Savary has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Gilles Courret
The School of Engineering and Management Vaud (Haute Ecole d’Ingénierie et de Gestion du Canton de Vaud—HEIG-VD), Route de Cheseaux 1, 1400 Yverdon-les-Bains, Switzerland
2 shared publications - Martine Baudin
Institute for Life Technologies, School of Engineering, University of Applied Sciences Western Switzerland Valais-Wallis (HES-SO Valais/Wallis), Rue de l’Industrie 23, 1950 Sion, Switzerland
2 shared publications - Martine Emery Mabillard
Institute for Life Technologies, School of Engineering, University of Applied Sciences Western Switzerland Valais-Wallis (HES-SO Valais/Wallis), Rue de l’Industrie 23, 1950 Sion, Switzerland
2 shared publications - Wolfram Manuel Brück
Institute of Life Sciences, University of Applied Sciences and Arts Western Switzerland Valais, Rue de l’Industrie 19, 1950 Sion, Switzerland
2 shared publications - Adrien Roux
School of Engineering, Architecture and Landscape of Geneva (HEPIA), HES-SO - University of Applied Sciences and Arts Western Switzerland
1 shared publication - Bernard Feuillard
School of Business and Engineering Vaud (HEIG-VD), University of Applied Science of Western Switzerland (HES-SO), 1401 Yverdon-les-Bains, Switzerland
1 shared publication
Latest Publications
- Open Access
- 31 July 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (8) , 926
Magnetic Milligripper Platform for Biomedical and Biological Applications
Achieving precise, untethered manipulation at the millimeter scale remains a fundamental challenge in minimally invasive medicine. Magnetic milligrippers have emerged as promising untethered tools for grasping, transporting, and releasing objects in confined anatomical environments, yet most existing rigid designs rely on multi-component assemblies with dedicated hinges or joints that require complex fabrication processes. Here, we present a simple, cost-effective rigid magnetic milligripper based on a folded titanium structure with two inclined permanent magnets. Actuated by a three-axis Helmholtz–Maxwell coil system, it enables orientation and translation control, as well as reversible opening. The actuation platform is coupled to a joystick-based control interface, allowing intuitive, real-time steering and opening of the milligripper by a single operator. The design is established with an analytical magnetic dipole model and validated through both finite-element simulations and experimental characterization, which together confirm reproducible, fully elastic operation across the investigated actuation range. The strong agreement between analytical, numerical, and experimental results establishes this architecture as a mechanically robust and scalable proof-of-concept platform for magnetic micromanipulation, with direct relevance to future minimally invasive biomedical applications.
- 31 July 2026
- Published by MDPI AG in Micromachines
- Vol. 17 (8) , 926
Open AccessMagnetic Milligripper Platform for Biomedical and Biological Applications
Achieving precise, untethered manipulation at the millimeter scale remains a fundamental challenge in minimally invasive medicine. Magnetic milligrippers have emerged as promising untethered tools for grasping, transporting, and releasing objects in confined anatomical environments, yet most existing rigid designs rely on multi-component assemblies with dedicated hinges or joints that require complex fabrication processes. Here, we present a simple, cost-effective rigid magnetic milligripper based on a folded titanium structure with two inclined permanent magnets. Actuated by a three-axis Helmholtz–Maxwell coil system, it enables orientation and translation control, as well as reversible opening. The actuation platform is coupled to a joystick-based control interface, allowing intuitive, real-time steering and opening of the milligripper by a single operator. The design is established with an analytical magnetic dipole model and validated through both finite-element simulations and experimental characterization, which together confirm reproducible, fully elastic operation across the investigated actuation range. The strong agreement between analytical, numerical, and experimental results establishes this architecture as a mechanically robust and scalable proof-of-concept platform for magnetic micromanipulation, with direct relevance to future minimally invasive biomedical applications.
- Open Access
Atmospheric Plasma Sources as Potential Tools for Surface and Hand Disinfection
Good hand hygiene has proven to be essential in reducing the uncontrolled spread of human pathogens. Cold atmospheric plasma (CAP) may provide an alternative to disinfecting hands with ethanol-based handrubs when handwashing facilities are unavailable. CAP can be safely applied to the skin if the energy is well controlled. In this study, radio frequency (RF) and direct current (DC) plasma sources were built with a pin-to-mesh electrodes configuration inside a fused silica tube with a 5 mm inner diameter. Microbiological assays based on EN 13697:2015+A1:2019 using Escherichia coli DSM 682 or Staphylococcus epidermidis DSM 20044 were used to examine the antimicrobial effect of various plasma conditions. Metal and silicone disks that model skin were used as inoculation matrices. The prototype air RF CAP achieved significant disinfection in the MHz range on stainless steel and silicone substrates. This is equivalent to half the performance of direct current CAP, which is only effective on conductive substrates. Using only electricity and air CAP could, with further optimization to increase its efficacy, replace or complement current hand disinfection methods, and mitigate the economic burden of public health crises in the future.
Open AccessAtmospheric Plasma Sources as Potential Tools for Surface and Hand Disinfection
Good hand hygiene has proven to be essential in reducing the uncontrolled spread of human pathogens. Cold atmospheric plasma (CAP) may provide an alternative to disinfecting hands with ethanol-based handrubs when handwashing facilities are unavailable. CAP can be safely applied to the skin if the energy is well controlled. In this study, radio frequency (RF) and direct current (DC) plasma sources were built with a pin-to-mesh electrodes configuration inside a fused silica tube with a 5 mm inner diameter. Microbiological assays based on EN 13697:2015+A1:2019 using Escherichia coli DSM 682 or Staphylococcus epidermidis DSM 20044 were used to examine the antimicrobial effect of various plasma conditions. Metal and silicone disks that model skin were used as inoculation matrices. The prototype air RF CAP achieved significant disinfection in the MHz range on stainless steel and silicone substrates. This is equivalent to half the performance of direct current CAP, which is only effective on conductive substrates. Using only electricity and air CAP could, with further optimization to increase its efficacy, replace or complement current hand disinfection methods, and mitigate the economic burden of public health crises in the future.
- Open Access
- 30 August 2023
- Published by MDPI AG in Preprints.org
Surface and Hand Disinfection Using Atmospheric Plasma Sources
Good hand hygiene has proven to be essential in reducing the uncontrolled spread of human pathogens. Cold atmospheric plasma (CAP) may provide an alternative to disinfecting hands with ethanol-based handrubs when hand washing facilities are unavailable. CAP can be safely applied to the skin if the energy is well controlled. In this study, RF and DC plasma sources was built with a pin-to-mesh electrodes configuration inside a fused silica tube of 5 mm of inner diameter. Microbiological assays based on EN 13697:2015+A1:2019 using Escherichia coli DSM 682 or Staphylococcus epidermidis DSM 20044 were used to examine the antimicrobial effect of various plasma conditions. Metal and silicone disks that model skin were used as inoculation matrices. The prototype air radio frequency (RF) CAP achieved significant disinfection in the MHz range on stainless steel and silicone substrates. This is equivalent to half the performance of direct current CAP, which is only effective on conductive substrates. Using only electricity and air CAP could, with further optimization, replace or complement current hand disinfection methods, and mitigate the economic burden of public health crises in the future.
- 30 August 2023
- Published by MDPI AG in Preprints.org
Open AccessSurface and Hand Disinfection Using Atmospheric Plasma Sources
Good hand hygiene has proven to be essential in reducing the uncontrolled spread of human pathogens. Cold atmospheric plasma (CAP) may provide an alternative to disinfecting hands with ethanol-based handrubs when hand washing facilities are unavailable. CAP can be safely applied to the skin if the energy is well controlled. In this study, RF and DC plasma sources was built with a pin-to-mesh electrodes configuration inside a fused silica tube of 5 mm of inner diameter. Microbiological assays based on EN 13697:2015+A1:2019 using Escherichia coli DSM 682 or Staphylococcus epidermidis DSM 20044 were used to examine the antimicrobial effect of various plasma conditions. Metal and silicone disks that model skin were used as inoculation matrices. The prototype air radio frequency (RF) CAP achieved significant disinfection in the MHz range on stainless steel and silicone substrates. This is equivalent to half the performance of direct current CAP, which is only effective on conductive substrates. Using only electricity and air CAP could, with further optimization, replace or complement current hand disinfection methods, and mitigate the economic burden of public health crises in the future.