Aleksei Yu. Smyslov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aleksei Yu. Smyslov has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- A. V. Anan’INa
Russian Scientific Center of Roentgenoradiology
2 shared publications - Elina S.-A. Shakhvalieva
Russian Scientific Center of Roentgenoradiology
2 shared publications - Mikhail E. Ivannikov
Russian Scientific Center of Roentgenoradiology
2 shared publications - Nikolay V. Nudnov
Russian Scientific Center of Roentgenoradiology
2 shared publications - Vladimir Mikhailovich Sotnikov
Russian Scientific Center of Roentgenoradiology
2 shared publications - A A Kokontsev
Federal State Budgetary Institution Russian Scientific Center of Roentgenoradiology (RSCRR) of the Ministry of Healthcare of the Russian Federation
1 shared publication
Latest Publications
- 20 September 2026
- Published by Elsevier in Physica Medica
- Vol. 150
Development and evaluation of a combined machine learning model for the prediction of acute GU toxicity in prostate cancer radiotherapy
- 20 September 2026
- Published by Elsevier in Physica Medica
- Vol. 150
Development and evaluation of a combined machine learning model for the prediction of acute GU toxicity in prostate cancer radiotherapy
- 1 August 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045053
Dosimetric evaluation of the RSCAN PP20 prototype plane-parallel ionization chamber in electron and kilovoltage x-ray beams
The RSCAN PP20 prototype plane-parallel ionization chamber was evaluated for electron beam dosimetry and medium-energy kilovoltage x-ray beam measurements. This study investigated its response constancy, linearity, depth-ionization characteristics, voltage and polarity dependence, and signal stability in water using a 6 MeV electron beam and selected kilovoltage x-ray beam qualities. Additional time-resolved measurements were performed to assess dark-field charge transients, post-irradiation charge relaxation, in-beam current transients, and cable-related parasitic currents, with a PTW Advanced Markus chamber used as a reference-control detector. In the 6 MeV electron beam, the RSCAN PP20 prototype produced physically plausible depth-ionization curves but showed insufficient quantitative stability. The coefficient of variation reached 1.57%, and the relative range reached 5.10%. The apparent linearity deviation reached 16.8% when background compensation was performed only once per measurement series, but decreased to 0.64% when repeated before each measurement. A polarity correction factor of approximately 0.91 was obtained across the tested voltage range, indicating measurement-chain asymmetry rather than a conventional intrinsic polarity effect. Time-resolved recordings revealed dark-field charge transients, post-beam charge accumulation, and mechanically induced bipolar current spikes, consistent with parasitic currents and possible cable-related triboelectric effects. Fixed-depth measurements in kilovoltage x-ray beams showed better short-term stability, whereas depth-response scans demonstrated cable-dependent distortions. The main limitation of the current RSCAN PP20 prototype is not its basic plane-parallel geometry, which is close to established clinical designs, but instability of the prototype chamber–cable assembly within the tested measurement setup. The prototype is not yet suitable for routine clinical dosimetry in its current configuration and requires hardware improvements followed by comprehensive recharacterization.
- 1 August 2026
- Published by IOP Publishing in Biomedical Physics & Engineering Express
- Vol. 12 (4) , 045053
Dosimetric evaluation of the RSCAN PP20 prototype plane-parallel ionization chamber in electron and kilovoltage x-ray beams
The RSCAN PP20 prototype plane-parallel ionization chamber was evaluated for electron beam dosimetry and medium-energy kilovoltage x-ray beam measurements. This study investigated its response constancy, linearity, depth-ionization characteristics, voltage and polarity dependence, and signal stability in water using a 6 MeV electron beam and selected kilovoltage x-ray beam qualities. Additional time-resolved measurements were performed to assess dark-field charge transients, post-irradiation charge relaxation, in-beam current transients, and cable-related parasitic currents, with a PTW Advanced Markus chamber used as a reference-control detector. In the 6 MeV electron beam, the RSCAN PP20 prototype produced physically plausible depth-ionization curves but showed insufficient quantitative stability. The coefficient of variation reached 1.57%, and the relative range reached 5.10%. The apparent linearity deviation reached 16.8% when background compensation was performed only once per measurement series, but decreased to 0.64% when repeated before each measurement. A polarity correction factor of approximately 0.91 was obtained across the tested voltage range, indicating measurement-chain asymmetry rather than a conventional intrinsic polarity effect. Time-resolved recordings revealed dark-field charge transients, post-beam charge accumulation, and mechanically induced bipolar current spikes, consistent with parasitic currents and possible cable-related triboelectric effects. Fixed-depth measurements in kilovoltage x-ray beams showed better short-term stability, whereas depth-response scans demonstrated cable-dependent distortions. The main limitation of the current RSCAN PP20 prototype is not its basic plane-parallel geometry, which is close to established clinical designs, but instability of the prototype chamber–cable assembly within the tested measurement setup. The prototype is not yet suitable for routine clinical dosimetry in its current configuration and requires hardware improvements followed by comprehensive recharacterization.
- Open Access
- 20 November 2024
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 5 (4) , 752-764
Use of radiomics and dosiomics to identify predictors of radiation induced lung injury
BACKGROUND: Radiomics is a machine learning based technology that extracts, analyzes, and interprets quantitative features from digital medical images. In recent years, dosiomics has become an increasingly common term in the literature to describe a new radiomics method. Dosiomics is a texture analysis method for evaluating radiotherapy dose distribution patterns. Most of the published research in dosiomics evaluates its use in predicting radiation induced lung injury. AIM: The aim of the study was to identify predictors (biomarkers) of radiation induced lung injury using texture analysis of computed tomography (CT) images of lungs and chest soft tissues using radiomics and dosiomics. MATERIALS AND METHODS: The study used data from 36 women with breast cancer who received postoperative conformal radiation therapy. Retrospectively, the patients were divided into two groups according to the severity of post radiation lung lesions. 3D Slicer was used to evaluate CT results of all patients obtained during radiation treatment planning and radiation dose distribution patterns. The software was able to unload radiomic and dosiomic features from regions of interest. The regions of interest included chest soft tissue and lung areas on the irradiated side where the dose burden exceeded 3 and 10 Gy. RESULTS: The first group included 13 patients with minimal radiation induced lung lesions, and the second group included 23 patients with post radiation pneumofibrosis. In the lung area on the side irradiated with more than 3 Gy, statistically significant differences between the patient groups were obtained for three radiomic features and one dosiomic feature. In the lung area on the side irradiated with more than 10 Gy, statistically significant differences were obtained for 12 radiomic features and 1 dosiomic feature. In the area of chest soft tissues on the irradiated side, significant differences were obtained for 18 radiomic features and 4 dosiomic features. CONCLUSIONS: As a result, a number of radiomic and dosiomic features were identified which were statistically different in patients with minimal lesions and pulmonary pneumofibrosis following radiation therapy for breast cancer. Based on texture analysis, predictors (biomarkers) were identified to predict post radiation lung injury and identify higher risk patients.
- 20 November 2024
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 5 (4) , 752-764
Open AccessUse of radiomics and dosiomics to identify predictors of radiation induced lung injury
BACKGROUND: Radiomics is a machine learning based technology that extracts, analyzes, and interprets quantitative features from digital medical images. In recent years, dosiomics has become an increasingly common term in the literature to describe a new radiomics method. Dosiomics is a texture analysis method for evaluating radiotherapy dose distribution patterns. Most of the published research in dosiomics evaluates its use in predicting radiation induced lung injury. AIM: The aim of the study was to identify predictors (biomarkers) of radiation induced lung injury using texture analysis of computed tomography (CT) images of lungs and chest soft tissues using radiomics and dosiomics. MATERIALS AND METHODS: The study used data from 36 women with breast cancer who received postoperative conformal radiation therapy. Retrospectively, the patients were divided into two groups according to the severity of post radiation lung lesions. 3D Slicer was used to evaluate CT results of all patients obtained during radiation treatment planning and radiation dose distribution patterns. The software was able to unload radiomic and dosiomic features from regions of interest. The regions of interest included chest soft tissue and lung areas on the irradiated side where the dose burden exceeded 3 and 10 Gy. RESULTS: The first group included 13 patients with minimal radiation induced lung lesions, and the second group included 23 patients with post radiation pneumofibrosis. In the lung area on the side irradiated with more than 3 Gy, statistically significant differences between the patient groups were obtained for three radiomic features and one dosiomic feature. In the lung area on the side irradiated with more than 10 Gy, statistically significant differences were obtained for 12 radiomic features and 1 dosiomic feature. In the area of chest soft tissues on the irradiated side, significant differences were obtained for 18 radiomic features and 4 dosiomic features. CONCLUSIONS: As a result, a number of radiomic and dosiomic features were identified which were statistically different in patients with minimal lesions and pulmonary pneumofibrosis following radiation therapy for breast cancer. Based on texture analysis, predictors (biomarkers) were identified to predict post radiation lung injury and identify higher risk patients.
- Open Access
- 26 September 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (3) , 340-355
Dosiomics in the analysis of medical images and prospects for its use in clinical practice
BACKGROUND: In recent years, there has been a notable increase in the number of articles using the term dosiomics. However, there are no literature reviews on this topic in the Russian language. AIM: This study aims to describe the basic principles of dosiomics as a derivative of radiomics and to analyze studies devoted to assessing the possibilities of its application in clinical practice. MATERIALS AND METHODS: A systematic literature search was performed in the PubMed database using the search query dosiomics OR dosiomic, and in the eLibrary database using the search query dosiomics. By April 2023, 43 foreign articles and 1 Russian article had been published. RESULTS: The analysis encompassed 43 foreign studies investigating the use of dosiomics in clinical practice, alongside one Russian article that provided a definition of the term dosiomics. The analyzed papers were divided into three groups according to their subject matter, and two tables describing the results of 27 studies on the prediction of clinical outcomes were created. CONCLUSION: Currently, dosiomics is a new and promising derivative of radiomics used in the textural analysis of medical images associated with radiation treatment of cancer patients. Dosiomics can contribute to the development of a more personalized approach to the planning of radiotherapy, the prediction of radiation damage of normal tissues, and the diagnosis of recurrence.
- 26 September 2023
- Published by ECO-Vector LLC in Digital Diagnostics
- Vol. 4 (3) , 340-355
Open AccessDosiomics in the analysis of medical images and prospects for its use in clinical practice
BACKGROUND: In recent years, there has been a notable increase in the number of articles using the term dosiomics. However, there are no literature reviews on this topic in the Russian language. AIM: This study aims to describe the basic principles of dosiomics as a derivative of radiomics and to analyze studies devoted to assessing the possibilities of its application in clinical practice. MATERIALS AND METHODS: A systematic literature search was performed in the PubMed database using the search query dosiomics OR dosiomic, and in the eLibrary database using the search query dosiomics. By April 2023, 43 foreign articles and 1 Russian article had been published. RESULTS: The analysis encompassed 43 foreign studies investigating the use of dosiomics in clinical practice, alongside one Russian article that provided a definition of the term dosiomics. The analyzed papers were divided into three groups according to their subject matter, and two tables describing the results of 27 studies on the prediction of clinical outcomes were created. CONCLUSION: Currently, dosiomics is a new and promising derivative of radiomics used in the textural analysis of medical images associated with radiation treatment of cancer patients. Dosiomics can contribute to the development of a more personalized approach to the planning of radiotherapy, the prediction of radiation damage of normal tissues, and the diagnosis of recurrence.