Cynthia Chuang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Cynthia Chuang has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Elham Rahimy
Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305, USA
2 shared publications - Erqi Liu Pollom
Stanford University
2 shared publications - Gregory Szalkowski
Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA 94305, USA
2 shared publications - Lei Wang
Stanford University
2 shared publications - Lianli Liu
Department of Radiation Oncology Stanford University Palo Alto California USA
2 shared publications - Scott G. Soltys
Department of Radiation Oncology, Stanford University School of Medicine, Stanford, California, USA
2 shared publications
Latest Publications
- Open Access
- 14 February 2025
- Published by MDPI AG in Brain Sciences
- Vol. 15 (2) , 199
Use of Carbon Fiber Implants to Improve the Safety and Efficacy of Radiation Therapy for Spine Tumor Patients
Current standard of care treatment for patients with spine tumors includes multidisciplinary approaches, including the following: (1) surgical tumor debulking, epidural spinal cord decompression, and spine stabilization techniques; (2) systemic chemo/targeted therapies; (3) radiation therapy; and (4) surveillance imaging for local disease control and recurrence. Titanium pedicle screw and rod fixation have become commonplace in the spine surgeon’s armamentarium for the stabilization of the spine following tumor resection and separation surgery. However, the high degree of imaging artifacts seen with titanium implants on postoperative CT and MRI scans can significantly hinder the accurate delineation of vertebral anatomy and adjacent neurovascular structures to allow for the safe and effective planning of downstream radiation therapies and detection of disease recurrence. Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) spine implants have emerged as a promising alternative to titanium due to the lack of artifact signals on CT and MRI, allowing for more accurate and safe postoperative radiation planning. In this article, we review the tenants of the surgical and radiation management of spine tumors and discuss the safety, efficacy, and current limitations of CFR-PEEK spine implants in the multidisciplinary management of spine oncology patients.
- 14 February 2025
- Published by MDPI AG in Brain Sciences
- Vol. 15 (2) , 199
Open AccessUse of Carbon Fiber Implants to Improve the Safety and Efficacy of Radiation Therapy for Spine Tumor Patients
Current standard of care treatment for patients with spine tumors includes multidisciplinary approaches, including the following: (1) surgical tumor debulking, epidural spinal cord decompression, and spine stabilization techniques; (2) systemic chemo/targeted therapies; (3) radiation therapy; and (4) surveillance imaging for local disease control and recurrence. Titanium pedicle screw and rod fixation have become commonplace in the spine surgeon’s armamentarium for the stabilization of the spine following tumor resection and separation surgery. However, the high degree of imaging artifacts seen with titanium implants on postoperative CT and MRI scans can significantly hinder the accurate delineation of vertebral anatomy and adjacent neurovascular structures to allow for the safe and effective planning of downstream radiation therapies and detection of disease recurrence. Carbon fiber-reinforced polyetheretherketone (CFR-PEEK) spine implants have emerged as a promising alternative to titanium due to the lack of artifact signals on CT and MRI, allowing for more accurate and safe postoperative radiation planning. In this article, we review the tenants of the surgical and radiation management of spine tumors and discuss the safety, efficacy, and current limitations of CFR-PEEK spine implants in the multidisciplinary management of spine oncology patients.
- Open Access
- 3 May 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (5) , 454
Where Does Auto-Segmentation for Brain Metastases Radiosurgery Stand Today?
Detection and segmentation of brain metastases (BMs) play a pivotal role in diagnosis, treatment planning, and follow-up evaluations for effective BM management. Given the rising prevalence of BM cases and its predominantly multiple onsets, automated segmentation is becoming necessary in stereotactic radiosurgery. It not only alleviates the clinician’s manual workload and improves clinical workflow efficiency but also ensures treatment safety, ultimately improving patient care. Recent strides in machine learning, particularly in deep learning (DL), have revolutionized medical image segmentation, achieving state-of-the-art results. This review aims to analyze auto-segmentation strategies, characterize the utilized data, and assess the performance of cutting-edge BM segmentation methodologies. Additionally, we delve into the challenges confronting BM segmentation and share insights gleaned from our algorithmic and clinical implementation experiences.
- 3 May 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (5) , 454
Open AccessWhere Does Auto-Segmentation for Brain Metastases Radiosurgery Stand Today?
Detection and segmentation of brain metastases (BMs) play a pivotal role in diagnosis, treatment planning, and follow-up evaluations for effective BM management. Given the rising prevalence of BM cases and its predominantly multiple onsets, automated segmentation is becoming necessary in stereotactic radiosurgery. It not only alleviates the clinician’s manual workload and improves clinical workflow efficiency but also ensures treatment safety, ultimately improving patient care. Recent strides in machine learning, particularly in deep learning (DL), have revolutionized medical image segmentation, achieving state-of-the-art results. This review aims to analyze auto-segmentation strategies, characterize the utilized data, and assess the performance of cutting-edge BM segmentation methodologies. Additionally, we delve into the challenges confronting BM segmentation and share insights gleaned from our algorithmic and clinical implementation experiences.
- 31 August 2023
- Published by Springer Nature
- p. 11-35
Physics of Stereotactic Radiosurgery and Stereotactic Body Radiotherapy
- 31 August 2023
- Published by Springer Nature
- p. 11-35
Physics of Stereotactic Radiosurgery and Stereotactic Body Radiotherapy
- 27 July 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (15) , 155019
Mitigating the uncertainty in small field dosimetry by leveraging machine learning strategies
Small field dosimetry is significantly different from the dosimetry of broad beams due to loss of electron side scatter equilibrium, source occlusion, and effects related to the choice of detector. However, use of small fields is increasing with the increase in indications for intensity-modulated radiation therapy and stereotactic body radiation therapy, and thus the need for accurate dosimetry is ever more important. Here we propose to leverage machine learning (ML) strategies to reduce the uncertainties and increase the accuracy in determining small field output factors (OFs). Linac OFs from a Varian TrueBeam STx were calculated either by the treatment planning system (TPS) or measured with a W1 scintillator detector at various multi-leaf collimator (MLC) positions, jaw positions, and with and without contribution from leaf-end transmission. The fields were defined by the MLCs with the jaws at various positions. Field sizes between 5 and 100 mm were evaluated. Separate ML regression models were generated based on the TPS calculated or the measured datasets. Accurate predictions of small field OFs at different field sizes (FSs) were achieved independent of jaw and MLC position. A mean and maximum % relative error of 0.38 ± 0.39% and 3.62%, respectively, for the best-performing models based on the measured datasets were found. The prediction accuracy was independent of contribution from leaf-end transmission. Several ML models for predicting small field OFs were generated, validated, and tested. Incorporating these models into the dose calculation workflow could greatly increase the accuracy and robustness of dose calculations for any radiotherapy delivery technique that relies heavily on small fields.
- 27 July 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (15) , 155019
Mitigating the uncertainty in small field dosimetry by leveraging machine learning strategies
Small field dosimetry is significantly different from the dosimetry of broad beams due to loss of electron side scatter equilibrium, source occlusion, and effects related to the choice of detector. However, use of small fields is increasing with the increase in indications for intensity-modulated radiation therapy and stereotactic body radiation therapy, and thus the need for accurate dosimetry is ever more important. Here we propose to leverage machine learning (ML) strategies to reduce the uncertainties and increase the accuracy in determining small field output factors (OFs). Linac OFs from a Varian TrueBeam STx were calculated either by the treatment planning system (TPS) or measured with a W1 scintillator detector at various multi-leaf collimator (MLC) positions, jaw positions, and with and without contribution from leaf-end transmission. The fields were defined by the MLCs with the jaws at various positions. Field sizes between 5 and 100 mm were evaluated. Separate ML regression models were generated based on the TPS calculated or the measured datasets. Accurate predictions of small field OFs at different field sizes (FSs) were achieved independent of jaw and MLC position. A mean and maximum % relative error of 0.38 ± 0.39% and 3.62%, respectively, for the best-performing models based on the measured datasets were found. The prediction accuracy was independent of contribution from leaf-end transmission. Several ML models for predicting small field OFs were generated, validated, and tested. Incorporating these models into the dose calculation workflow could greatly increase the accuracy and robustness of dose calculations for any radiotherapy delivery technique that relies heavily on small fields.
- Open Access
- 27 May 2020
- Published by Springer Nature in Cureus
- Vol. 12 (5) , e8324
ZAP-X: A Novel Radiosurgical Device for the Treatment of Trigeminal Neuralgia
The treatment of trigeminal neuralgia (TN) is one of the most demanding of all radiosurgery procedures, requiring accurate delivery and sharp dose fall off. ZAP-X®, a new, innovative frameless radiosurgical device, maybe an attractive platform for the treatment of TN and other functional brain disorders. Here, we compared the dosimetry of ZAP-X plans for a single patient to that generated by a well-established dedicated radiosurgery device, the CyberKnife. Radiosurgery plans that delineated the cranial nerve from a single patient’s fused computed tomography and magnetic resonance imaging (CT-MR) data set were planned on both the ZAP-X and CyberKnife, with the latter serving as a validated benchmark. The same target and treatment planning constraints were applied. Plans were evaluated by a physician with experience treating TN and a medical physicist. The ZAP-X treatment plan used two isocenters delivered through 4-mm collimators based on a non-isocentric plan that delivered 29,441 MU through 81 beams. The CyberKnife plans used a 5-mm collimator for a non-isocentric plan that delivered 17,880 MU through 88 beams. Based on visual inspection, the isodose volumes covered by ZAP-X and CyberKnife were similar at the prescription isodose (70% and 80%, respectively, with a maximum dose (Dmax) of 7500 cGy. The conformality index was better for the CyberKnife as compared to ZAP-X. However, the irradiated volumes were smaller at the 50%, 20%, and 10% isodoses for ZAP-X (0.12 cc, 0.57 cc, and 1.69 for ZAP-X; 0.18 cc, 0.91 cc, and 3.41 cc for CyberKnife). In particular, the 20% and 10% isodose volumes were much smaller for ZAP-X, especially on the axial and sagittal planes. ZAP-X treatment planning for TN compares favorably with equivalent planning on CyberKnife. The brain volumes containing the 20% and 10% isodoses are smaller using ZAP-X, thus relatively sparing critical structures close to the target, including the Gasserian ganglion and brainstem. This feature could be of clinical relevance by potentially reducing treatment-related complications.
- 27 May 2020
- Published by Springer Nature in Cureus
- Vol. 12 (5) , e8324
Open AccessZAP-X: A Novel Radiosurgical Device for the Treatment of Trigeminal Neuralgia
The treatment of trigeminal neuralgia (TN) is one of the most demanding of all radiosurgery procedures, requiring accurate delivery and sharp dose fall off. ZAP-X®, a new, innovative frameless radiosurgical device, maybe an attractive platform for the treatment of TN and other functional brain disorders. Here, we compared the dosimetry of ZAP-X plans for a single patient to that generated by a well-established dedicated radiosurgery device, the CyberKnife. Radiosurgery plans that delineated the cranial nerve from a single patient’s fused computed tomography and magnetic resonance imaging (CT-MR) data set were planned on both the ZAP-X and CyberKnife, with the latter serving as a validated benchmark. The same target and treatment planning constraints were applied. Plans were evaluated by a physician with experience treating TN and a medical physicist. The ZAP-X treatment plan used two isocenters delivered through 4-mm collimators based on a non-isocentric plan that delivered 29,441 MU through 81 beams. The CyberKnife plans used a 5-mm collimator for a non-isocentric plan that delivered 17,880 MU through 88 beams. Based on visual inspection, the isodose volumes covered by ZAP-X and CyberKnife were similar at the prescription isodose (70% and 80%, respectively, with a maximum dose (Dmax) of 7500 cGy. The conformality index was better for the CyberKnife as compared to ZAP-X. However, the irradiated volumes were smaller at the 50%, 20%, and 10% isodoses for ZAP-X (0.12 cc, 0.57 cc, and 1.69 for ZAP-X; 0.18 cc, 0.91 cc, and 3.41 cc for CyberKnife). In particular, the 20% and 10% isodose volumes were much smaller for ZAP-X, especially on the axial and sagittal planes. ZAP-X treatment planning for TN compares favorably with equivalent planning on CyberKnife. The brain volumes containing the 20% and 10% isodoses are smaller using ZAP-X, thus relatively sparing critical structures close to the target, including the Gasserian ganglion and brainstem. This feature could be of clinical relevance by potentially reducing treatment-related complications.