Jens Schneider
Research Subjects
Research Interests
Jens Schneider has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Maria Nobili
Department of Orthopaedic and Trauma Surgery, Eifelklinik St. Brigida, Simmerath, Germany
3 shared publications - Andreas Bell
Department of Orthopaedic and Trauma Surgery, Eifelklinik St. Brigida, Simmerath, Germany
3 shared publications - Daniel Kämmer
Department of Orthopaedic and Trauma Surgery, Eifelklinik St. Brigida, Simmerath, Germany
3 shared publications - Filippo Migliorini
Department of Trauma and Reconstructive Surgery, University Hospital of Halle, Martin-Luther University Halle-Wittenberg, Halle (Saale), Germany
3 shared publications - Luise Schäfer
Department of Orthopaedic and Trauma Surgery, Eifelklinik St. Brigida, Simmerath, Germany
2 shared publications - Nicola Maffulli
Department of Trauma and Orthopaedic Surgery, Faculty of Medicine and Psychology, Sapienza University of Rome, Rome, Italy
2 shared publications
Latest Publications
- Open Access
- 3 November 2026
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 27 (1) , 63
Robotic-assisted total knee arthroplasty demonstrates superior early functional outcomes compared with conventional total knee arthroplasty: a quasi-randomised controlled trial
Background: Robotic-assisted total knee arthroplasty (TKA) has gained popularity over the last decade, with claimed advantages in implant positioning accuracy and soft-tissue balance. Whether these technical advantages translate into better clinical outcomes for patients remains debated. This investigation compared 1-year patient-reported outcomes between robotic-assisted and conventional TKA performed within the same institution but following structurally different surgical workflows. Methods: This quasi-randomised controlled trial enrolled patients who underwent primary TKA at the Department of Orthopaedic and Trauam Surgery of the Eifelklink St. Brigida (Simmerath, Germany) between 2022 and 2025. Group allocation was determined by surgeon assignment through the institutional digital scheduling system. All patients received the same implant (Smith & Nephew Legion Genesis II, posterior-stabilised). Robotic-assisted procedures were performed using the CORI Robotic System (Smith & Nephew, UK) following a four-dimensional personalised alignment workflow (coronal, sagittal, transversal and balancing) guided intraoperatively by the Knee Balancing Score (KBS). Conventional procedures followed a femur-first technique with adjusted mechanical alignment. Outcomes included WOMAC total and subscores, visual analogue scale (VAS), Tegner activity score and a dedicated functional questionnaire, all assessed at 1-year follow-up. Results: A total of 845 patients were included (robotic-assisted: n = 390; conventional: n = 455). At 1-year, 383 and 445 patients completed follow-up, respectively. The two groups were comparable at baseline. The robotic-assisted cohort showed significantly better results across WOMAC and related subscales ( P < 0.001), VAS ( P < 0.001), Tegner ( P < 0.001), functional and satisfaction items, including walking distance and knee stability. No difference was found in the use of walking aids. Conclusions: Robotic-assisted TKA was associated with superior functional and patient-reported outcomes at the 1-year follow-up. The clinical benefit observed is likely not attributable to robotic precision alone, but reflects the structured, personalised intraoperative workflow that robotic assistance enables. Trial Registry German Registry of Clinical Trials (ID DRKS00030614).
- 3 November 2026
- Published by Springer Nature in Journal of Orthopaedics and Traumatology
- Vol. 27 (1) , 63
Open AccessRobotic-assisted total knee arthroplasty demonstrates superior early functional outcomes compared with conventional total knee arthroplasty: a quasi-randomised controlled trial
Background: Robotic-assisted total knee arthroplasty (TKA) has gained popularity over the last decade, with claimed advantages in implant positioning accuracy and soft-tissue balance. Whether these technical advantages translate into better clinical outcomes for patients remains debated. This investigation compared 1-year patient-reported outcomes between robotic-assisted and conventional TKA performed within the same institution but following structurally different surgical workflows. Methods: This quasi-randomised controlled trial enrolled patients who underwent primary TKA at the Department of Orthopaedic and Trauam Surgery of the Eifelklink St. Brigida (Simmerath, Germany) between 2022 and 2025. Group allocation was determined by surgeon assignment through the institutional digital scheduling system. All patients received the same implant (Smith & Nephew Legion Genesis II, posterior-stabilised). Robotic-assisted procedures were performed using the CORI Robotic System (Smith & Nephew, UK) following a four-dimensional personalised alignment workflow (coronal, sagittal, transversal and balancing) guided intraoperatively by the Knee Balancing Score (KBS). Conventional procedures followed a femur-first technique with adjusted mechanical alignment. Outcomes included WOMAC total and subscores, visual analogue scale (VAS), Tegner activity score and a dedicated functional questionnaire, all assessed at 1-year follow-up. Results: A total of 845 patients were included (robotic-assisted: n = 390; conventional: n = 455). At 1-year, 383 and 445 patients completed follow-up, respectively. The two groups were comparable at baseline. The robotic-assisted cohort showed significantly better results across WOMAC and related subscales ( P < 0.001), VAS ( P < 0.001), Tegner ( P < 0.001), functional and satisfaction items, including walking distance and knee stability. No difference was found in the use of walking aids. Conclusions: Robotic-assisted TKA was associated with superior functional and patient-reported outcomes at the 1-year follow-up. The clinical benefit observed is likely not attributable to robotic precision alone, but reflects the structured, personalised intraoperative workflow that robotic assistance enables. Trial Registry German Registry of Clinical Trials (ID DRKS00030614).
- 16 October 2026
- Published by Springer Nature in Die Orthopädie
- p. 1-3
Clarifying allocation, measurement reliability and phenotype reporting in robotic-assisted TKA
- 16 October 2026
- Published by Springer Nature in Die Orthopädie
- p. 1-3
Clarifying allocation, measurement reliability and phenotype reporting in robotic-assisted TKA
- Open Access
- 25 August 2023
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-8
Robotic-assisted total knee arthroplasty in clinical practice: protocol for a randomised controlled trial
Between 2 and 20% of patients who undergo total knee arthroplasty (TKA) report restricted motion and anterior knee pain. Non-optimal alignment of the implant components is a common cause of such complaints. Robotic-assisted TKA has been advocated to improve the accuracy of component positioning to match patients’ anatomy and biomechanics. However, the advantages of robotic surgery over conventional freehand TKA are still unclear. The present study is a protocol for a single-blind clinical trial in which patients will be randomly allocated to undergo either robotic-assisted TKA or conventional freehand TKA. A restricted kinematic alignment with medial para-stellar approach shall be made in all patients. The present study follows the SPIRIT guidelines. The primary outcome of interest is to compare robotic TKA versus traditional freehand TKA in terms of patient-reported outcome measures (PROMs), length of hospitalisation, blood values, blood transfusion units, and range of motion. The second outcome of interest is to evaluate the accuracy of component positioning of robotic-assisted TKA compared to the conventional freehand TKA.Level of evidence Level I, randomised controlled trial.Registration German Registry of Clinical Trials (ID: DRKS00030614).
- 25 August 2023
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 18 (1) , 1-8
Open AccessRobotic-assisted total knee arthroplasty in clinical practice: protocol for a randomised controlled trial
Between 2 and 20% of patients who undergo total knee arthroplasty (TKA) report restricted motion and anterior knee pain. Non-optimal alignment of the implant components is a common cause of such complaints. Robotic-assisted TKA has been advocated to improve the accuracy of component positioning to match patients’ anatomy and biomechanics. However, the advantages of robotic surgery over conventional freehand TKA are still unclear. The present study is a protocol for a single-blind clinical trial in which patients will be randomly allocated to undergo either robotic-assisted TKA or conventional freehand TKA. A restricted kinematic alignment with medial para-stellar approach shall be made in all patients. The present study follows the SPIRIT guidelines. The primary outcome of interest is to compare robotic TKA versus traditional freehand TKA in terms of patient-reported outcome measures (PROMs), length of hospitalisation, blood values, blood transfusion units, and range of motion. The second outcome of interest is to evaluate the accuracy of component positioning of robotic-assisted TKA compared to the conventional freehand TKA.Level of evidence Level I, randomised controlled trial.Registration German Registry of Clinical Trials (ID: DRKS00030614).