Asif Ahmed Rahmoon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Asif Ahmed Rahmoon has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Dur Muhammad Soomro
Universiti Tun Hussein Onn Malaysia
2 shared publications - Feryal Ibrahim Jabbar
Al-Mustaqbal University College
2 shared publications - Hassan Falah Fakhruldeen
Computer Techniques Engineering Department, Faculty of Information Technology, Imam Ja’afar Al-Sadiq University, Baghdad, Iraq
2 shared publications - Mazhar Hussain Baloch
Department of Electrical Engineering and Computer Science, College of Engineering, A’Sharqiyah University, Ibra 400, Oman
2 shared publications - Mohd Noor Abdullah
Universiti Tun Hussein Onn Malaysia
2 shared publications - Nur Hanis Radzi
Universiti Tun Hussein Onn Malaysia
2 shared publications
Latest Publications
- Open Access
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 14 (4) , 2044-2051
Detection of single line to ground fault and self-extinguishing by using a variable and a fixedable inductance in distribution grid in power
This paper tackled the method for determining the number of Peterson coil which is can compensate with the capacitance because it is important in determining the state of parallel resonance, which in turn control the ground fault current and make the approximate value of the current equal to the current in the sound phases. In this way, we can protect the electrical devices and equipment from being damaged by residual current resulting from the arc due to ground fault, which increases the temperature of conductors which are to a breakdown of insulators and damaging them. Ground fault current equals three times the actual current, and its effect depends on two types of variables which are the first: the number of Peterson coils (which specify the inductance value and compensated) and second: the period time of extinguishing electric are in the ground fault. we obtain, by experimental in the lab where it using the servo motor to control the number of Peterson coils which in turn specify the variable and invariable inductance. We have obtained optimal results for the value of ground-fault current, detect the ground fault and treat it without effect of network load and without power cut off for consumer.
- 1 December 2023
- Published by Institute of Advanced Engineering and Science in International Journal of Power Electronics and Drive Systems (IJPEDS)
- Vol. 14 (4) , 2044-2051
Open AccessDetection of single line to ground fault and self-extinguishing by using a variable and a fixedable inductance in distribution grid in power
This paper tackled the method for determining the number of Peterson coil which is can compensate with the capacitance because it is important in determining the state of parallel resonance, which in turn control the ground fault current and make the approximate value of the current equal to the current in the sound phases. In this way, we can protect the electrical devices and equipment from being damaged by residual current resulting from the arc due to ground fault, which increases the temperature of conductors which are to a breakdown of insulators and damaging them. Ground fault current equals three times the actual current, and its effect depends on two types of variables which are the first: the number of Peterson coils (which specify the inductance value and compensated) and second: the period time of extinguishing electric are in the ground fault. we obtain, by experimental in the lab where it using the servo motor to control the number of Peterson coils which in turn specify the variable and invariable inductance. We have obtained optimal results for the value of ground-fault current, detect the ground fault and treat it without effect of network load and without power cut off for consumer.
- Open Access
- 1 September 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 31 (3) , 1286-1294
Optimize single line to ground fault detection in distribution grid power system using artificial bee colony
The most common power system (PS) distribution network fault, single lineto-ground fault (SLGF), causes residual current (I res) to start an electrical arc and high voltage (HV) three times the rated voltage in other healthy phases. HV from capacitive currents (IC) damages cable insulation and PS appliances. Peterson The neutral point coil (PC) reduces (I res) and extinguishes the electric arc, but the fault current (I fault) remains below the protection devices' threshold. Operations and equipment are riskier. PC adaptive eliminates electrical arcs, making the network safer. This paper detects I faults online using Texas instrument validation in MATLAB and adaptive by artificial bee colony (ABC). This paper discusses Texas instrument fault current detection and MATLAB validation. It improves system reliability, device protection, and copper savings by thousands of tons. ABC intelligently optimizes many mathematical problems. ABC with network neural artificial intelligence (AI) improves algorithm performance (artificial bee colony network neural (ABCNN)). This new method may improve distribution network SLGF detection. This first work can work online in electrical power stations by building the (eZdsp F28335-RS232) into the program to send fault signals to the control when SLGF occurs without damaging devices, equipment, cables, or power outages.
- 1 September 2023
- Published by Institute of Advanced Engineering and Science in Indonesian Journal of Electrical Engineering and Computer Science
- Vol. 31 (3) , 1286-1294
Open AccessOptimize single line to ground fault detection in distribution grid power system using artificial bee colony
The most common power system (PS) distribution network fault, single lineto-ground fault (SLGF), causes residual current (I res) to start an electrical arc and high voltage (HV) three times the rated voltage in other healthy phases. HV from capacitive currents (IC) damages cable insulation and PS appliances. Peterson The neutral point coil (PC) reduces (I res) and extinguishes the electric arc, but the fault current (I fault) remains below the protection devices' threshold. Operations and equipment are riskier. PC adaptive eliminates electrical arcs, making the network safer. This paper detects I faults online using Texas instrument validation in MATLAB and adaptive by artificial bee colony (ABC). This paper discusses Texas instrument fault current detection and MATLAB validation. It improves system reliability, device protection, and copper savings by thousands of tons. ABC intelligently optimizes many mathematical problems. ABC with network neural artificial intelligence (AI) improves algorithm performance (artificial bee colony network neural (ABCNN)). This new method may improve distribution network SLGF detection. This first work can work online in electrical power stations by building the (eZdsp F28335-RS232) into the program to send fault signals to the control when SLGF occurs without damaging devices, equipment, cables, or power outages.