ARAsif Ahmed Rahmoon

Asif Ahmed Rahmoon

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Asif Ahmed Rahmoon has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Detection of single line to ground fault and self-extinguishing by using a variable and a fixedable inductance in distribution grid in power

    by Feryal Ibrahim Jabbar, Dur Muhammad Soomro, Mohd Noor bin Abdullah, Nur Hanis Binti Mohammad Radzi, Mazhar Hussain Baloch, Asif Ahmed Rahmoon, Hassan Falah Fakhruldeen

    This paper tackled the method for determining the number of Peterson coil which is can compensate with the capacitance because it is important in determining the state of parallel resonance, which in turn control the ground fault current and make the approximate value of the current equal to the current in the sound phases. In this way, we can protect the electrical devices and equipment from being damaged by residual current resulting from the arc due to ground fault, which increases the temperature of conductors which are to a breakdown of insulators and damaging them. Ground fault current equals three times the actual current, and its effect depends on two types of variables which are the first: the number of Peterson coils (which specify the inductance value and compensated) and second: the period time of extinguishing electric are in the ground fault. we obtain, by experimental in the lab where it using the servo motor to control the number of Peterson coils which in turn specify the variable and invariable inductance. We have obtained optimal results for the value of ground-fault current, detect the ground fault and treat it without effect of network load and without power cut off for consumer.

  • Open Access

    Optimize single line to ground fault detection in distribution grid power system using artificial bee colony

    by Feryal Ibrahim Jabbar, Dur Muhammad Soomro, Mohd Noor bin Abdullah, Nur Hanis Mohammad Radzi, Mazhar Hussain Baloch, Asif Ahmed Rahmoon, Hassan Falah Fakhruldeen

    The most common power system (PS) distribution network fault, single lineto-ground fault (SLGF), causes residual current (I res) to start an electrical arc and high voltage (HV) three times the rated voltage in other healthy phases. HV from capacitive currents (IC) damages cable insulation and PS appliances. Peterson The neutral point coil (PC) reduces (I res) and extinguishes the electric arc, but the fault current (I fault) remains below the protection devices' threshold. Operations and equipment are riskier. PC adaptive eliminates electrical arcs, making the network safer. This paper detects I faults online using Texas instrument validation in MATLAB and adaptive by artificial bee colony (ABC). This paper discusses Texas instrument fault current detection and MATLAB validation. It improves system reliability, device protection, and copper savings by thousands of tons. ABC intelligently optimizes many mathematical problems. ABC with network neural artificial intelligence (AI) improves algorithm performance (artificial bee colony network neural (ABCNN)). This new method may improve distribution network SLGF detection. This first work can work online in electrical power stations by building the (eZdsp F28335-RS232) into the program to send fault signals to the control when SLGF occurs without damaging devices, equipment, cables, or power outages.