Nathan Ronceray
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nathan Ronceray has a total of 104 co-authors. Here are the top co-authors by number of shared publications:
- Aleksandra Radenovic
Institute of Bioengineering, School of Engineering, EPFL, Lausanne, Switzerland
13 shared publications - Theo Emmerich
Institute of Bioengineering, School of Engineering, EPFL, Lausanne, Switzerland
5 shared publications - Boya Radha
National Graphene Institute, The University of Manchester, Manchester, UK
3 shared publications - Maria Josefina Marcaida
Institute of Bioengineering School of Life Sciences Ecole Polytechnique Fédérale de Lausanne Lausanne Switzerland
3 shared publications Marianna Fanouria Mitsioni
Institute of Bioengineering, School of Engineering, Swiss Federal Institute of Technology Lausanne, Lausanne, Switzerland
3 shared publications- Matteo Dal Peraro
Institute of Bioengineering School of Life Sciences Ecole Polytechnique Fédérale de Lausanne Lausanne Switzerland
3 shared publications
Latest Publications
- Open Access
- 27 October 2026
- Published by Springer Nature in Nature Materials
- p. 1-9
Direct imaging elucidates ionic memory in two-dimensional nanochannels
Nanofluidic memristors promise brain-inspired information processing with ions, yet their microscopic origin remains debated. So far, ionic memory has been attributed to ion-specific interactions, dynamic wetting, chemical reactions or mechanical deformations, yet typically without direct experimental evidence. Here, by combining operando interferometric imaging with electrokinetic measurements, we directly visualize voltage-induced blistering of the confining walls of two-dimensional (2D) nanochannels as the key origin of memristive hysteresis. We identify two distinct classes of blisters: unidirectional, driven by electrostatic forces on surface charges, and bidirectional, arising from osmotic pressure due to concentration polarization. This mechanistic framework explains device evolution and device-to-device variability, and reframes stochastic blistering as a functional design element. Our results constitute a direct proof of electromechanical coupling as a robust pathway to ionic memory in 2D nanochannels and open routes towards high-performance ionic memristors and electrically actuated nanofluidic valves.
- 27 October 2026
- Published by Springer Nature in Nature Materials
- p. 1-9
Open AccessDirect imaging elucidates ionic memory in two-dimensional nanochannels
Nanofluidic memristors promise brain-inspired information processing with ions, yet their microscopic origin remains debated. So far, ionic memory has been attributed to ion-specific interactions, dynamic wetting, chemical reactions or mechanical deformations, yet typically without direct experimental evidence. Here, by combining operando interferometric imaging with electrokinetic measurements, we directly visualize voltage-induced blistering of the confining walls of two-dimensional (2D) nanochannels as the key origin of memristive hysteresis. We identify two distinct classes of blisters: unidirectional, driven by electrostatic forces on surface charges, and bidirectional, arising from osmotic pressure due to concentration polarization. This mechanistic framework explains device evolution and device-to-device variability, and reframes stochastic blistering as a functional design element. Our results constitute a direct proof of electromechanical coupling as a robust pathway to ionic memory in 2D nanochannels and open routes towards high-performance ionic memristors and electrically actuated nanofluidic valves.
- Open Access
- 16 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Emission dipole orientation reveals dynamic single-molecule interactions with 2D crystals at solvent interfaces
Direct observation of individual fluorescent emitters is essential for studying quantum materials, chemical reactions, and biological systems. However, current single-molecule tracking methods only focuses on the localizations of molecules, overlooking molecular configuration and orientation. In this work, we introduce a high-throughput polarized single-molecule localization microscopy that simultaneously resolves the locations and emission dipole orientations of single fluorescent emitters with nanometer precision. Using the interface between pristine hexagonal boron nitride (h-BN) and an organic solvent as a challenging platform, we capture over 10⁵ fluorescent events and reveal distinct molecular interaction dynamics at room temperature. The measured dipole orientations align with the three-fold (C₃) rotational symmetry of the h-BN lattice, and molecular dynamics in the liquid environment can be modulated electrochemically, suggesting a route for on-demand control of quantum emitters. We also find that lateral diffusion at the solid–liquid interface is far more dynamic than that of solid-state emitters. This simultaneous tracking of molecular conformation and photophysics advances the understanding of single-molecule interactions and enables real-time sensing through two-dimensional materials.
- 16 June 2026
- Published by Springer Nature in Nature Communications
- Vol. 17 (1)
Open AccessEmission dipole orientation reveals dynamic single-molecule interactions with 2D crystals at solvent interfaces
Direct observation of individual fluorescent emitters is essential for studying quantum materials, chemical reactions, and biological systems. However, current single-molecule tracking methods only focuses on the localizations of molecules, overlooking molecular configuration and orientation. In this work, we introduce a high-throughput polarized single-molecule localization microscopy that simultaneously resolves the locations and emission dipole orientations of single fluorescent emitters with nanometer precision. Using the interface between pristine hexagonal boron nitride (h-BN) and an organic solvent as a challenging platform, we capture over 10⁵ fluorescent events and reveal distinct molecular interaction dynamics at room temperature. The measured dipole orientations align with the three-fold (C₃) rotational symmetry of the h-BN lattice, and molecular dynamics in the liquid environment can be modulated electrochemically, suggesting a route for on-demand control of quantum emitters. We also find that lateral diffusion at the solid–liquid interface is far more dynamic than that of solid-state emitters. This simultaneous tracking of molecular conformation and photophysics advances the understanding of single-molecule interactions and enables real-time sensing through two-dimensional materials.
- Open Access
- 11 November 2025
- Published by Springer Nature in Nature Nanotechnology
- Vol. 21 (1) , 116-124
Lumen charge governs gated ion transport in β-barrel nanopores
β-Barrel nanopores are involved in crucial biological processes, from ATP export in mitochondria to bacterial resistance, and represent a promising platform for emerging sequencing technologies. However, in contrast to ion channels, the understanding of the fundamental principles governing ion transport through these nanopores remains largely unexplored. Here we integrate experimental, numerical and theoretical approaches to elucidate ion transport mechanisms in β-barrel nanopores. We identify and characterize two distinct nonlinear phenomena: open-pore rectification and gating. Through extensive mutation analysis of aerolysin nanopores, we demonstrate that open-pore rectification is caused by ionic accumulation driven by the distribution of lumen charges. In addition, we provide converging evidence suggesting that gating is controlled by electric fields dissociating counterions from lumen charges, promoting local structural deformations. Our findings establish a rigorous framework for characterizing and understanding ion transport processes in protein-based nanopores, enabling the design of adaptable nanofluidic biotechnologies. We illustrate this by optimizing an aerolysin mutant for computing applications.
- 11 November 2025
- Published by Springer Nature in Nature Nanotechnology
- Vol. 21 (1) , 116-124
Open AccessLumen charge governs gated ion transport in β-barrel nanopores
β-Barrel nanopores are involved in crucial biological processes, from ATP export in mitochondria to bacterial resistance, and represent a promising platform for emerging sequencing technologies. However, in contrast to ion channels, the understanding of the fundamental principles governing ion transport through these nanopores remains largely unexplored. Here we integrate experimental, numerical and theoretical approaches to elucidate ion transport mechanisms in β-barrel nanopores. We identify and characterize two distinct nonlinear phenomena: open-pore rectification and gating. Through extensive mutation analysis of aerolysin nanopores, we demonstrate that open-pore rectification is caused by ionic accumulation driven by the distribution of lumen charges. In addition, we provide converging evidence suggesting that gating is controlled by electric fields dissociating counterions from lumen charges, promoting local structural deformations. Our findings establish a rigorous framework for characterizing and understanding ion transport processes in protein-based nanopores, enabling the design of adaptable nanofluidic biotechnologies. We illustrate this by optimizing an aerolysin mutant for computing applications.
- Open Access
- 4 August 2025
- Published by Springer Nature in Light: Science & Applications
- Vol. 14 (1) , 1-11
Wide-field fluorescence lifetime imaging of single molecules with a gated single-photon camera
Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool to discriminate fluorescent molecules or probe their nanoscale environment. Traditionally, FLIM uses time-correlated single-photon counting (TCSPC), which is precise but intrinsically low-throughput due to its dependence on point detectors. Although time-gated cameras have demonstrated the potential for high-throughput FLIM in bright samples with dense labeling, their use in single-molecule microscopy has not been explored extensively. Here, we report fast and accurate single-molecule FLIM with a commercial time-gated single-photon camera. Our optimized acquisition scheme achieves single-molecule lifetime measurements with a precision only about three times less than TCSPC, while imaging with a large number of pixels (512 × 512) allowing for the spatial multiplexing of over 3000 molecules. With this approach, we demonstrate parallelized lifetime measurements of large numbers of labeled pore-forming proteins on supported lipid bilayers, and temporal single-molecule Förster resonance energy transfer measurements at 5-25 Hz. This method holds considerable promise for the advancement of multi-target single-molecule localization microscopy and biopolymer sequencing.
- 4 August 2025
- Published by Springer Nature in Light: Science & Applications
- Vol. 14 (1) , 1-11
Open AccessWide-field fluorescence lifetime imaging of single molecules with a gated single-photon camera
Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool to discriminate fluorescent molecules or probe their nanoscale environment. Traditionally, FLIM uses time-correlated single-photon counting (TCSPC), which is precise but intrinsically low-throughput due to its dependence on point detectors. Although time-gated cameras have demonstrated the potential for high-throughput FLIM in bright samples with dense labeling, their use in single-molecule microscopy has not been explored extensively. Here, we report fast and accurate single-molecule FLIM with a commercial time-gated single-photon camera. Our optimized acquisition scheme achieves single-molecule lifetime measurements with a precision only about three times less than TCSPC, while imaging with a large number of pixels (512 × 512) allowing for the spatial multiplexing of over 3000 molecules. With this approach, we demonstrate parallelized lifetime measurements of large numbers of labeled pore-forming proteins on supported lipid bilayers, and temporal single-molecule Förster resonance energy transfer measurements at 5-25 Hz. This method holds considerable promise for the advancement of multi-target single-molecule localization microscopy and biopolymer sequencing.
- Open Access
Single-Photon Single-Particle Tracking
Mobile biological particles, ranging from biomolecules to viral capsids, often diffuse faster than 1 µ m 2 /s, resulting in severe motion blur in conventional millisecond-scale imaging. While shorter exposures may help provide the data needed to capture faster dynamics, quantization of signal intensity per pixel at such exposures eventually interferes with our ability to track. In the extreme case of binary (1-bit-per-pixel) output— where going from 8-bit conventional grayscale imaging to 1-bit directly corresponds to a 255-fold faster acquisition rate—no existing tracking methods can be used, as these methods fundamentally rely on intensity-based localization, which does not leverage the binary output. For this reason, we introduce single-photon single-particle tracking (SP 2 T), a framework that bypasses localization and linking by estimating particle numbers and trajectories directly by jointly considering 1-bit image stacks. While cameras capable of microsecond-scale exposures, typically based on scientific CMOS (sCMOS) sensors or single-photon detectors (SPDs), are increasingly central to this effort, in this work, we focus on single-photon avalanche diode (SPAD). Single-photon detector (SPD) arrays offer microsecond exposures over large fields of view (512×512 pixels). SP 2 T accounts for detector-specific artifacts such as hot and cold pixels and is validated with programmed fluorescent bead trajectories and biological systems (aerolysin and ganglioside). These experiments, in addition to simulations, reveal that analysis performed with longer exposures can bias diffusion coefficient estimates (up to 70% for particles with diffusion coefficients of 5 µ m 2 /s) and distort jump-distance distributions, underscoring the need for photon-by-photon tracking in fast-diffusion regimes. Moreover, SP 2 T delivers substantial computational gains—achieving more than a 50-fold GPU speedup over CPU-based likelihood tracking methods that assume continuous intensity, when compared on datasets with the same frame size and number of frames. Together, these advances establish SP 2 T as a robust, data-efficient solution for unbiased particle tracking with millisecond-to-microsecond temporal resolution.
Open AccessSingle-Photon Single-Particle Tracking
Mobile biological particles, ranging from biomolecules to viral capsids, often diffuse faster than 1 µ m 2 /s, resulting in severe motion blur in conventional millisecond-scale imaging. While shorter exposures may help provide the data needed to capture faster dynamics, quantization of signal intensity per pixel at such exposures eventually interferes with our ability to track. In the extreme case of binary (1-bit-per-pixel) output— where going from 8-bit conventional grayscale imaging to 1-bit directly corresponds to a 255-fold faster acquisition rate—no existing tracking methods can be used, as these methods fundamentally rely on intensity-based localization, which does not leverage the binary output. For this reason, we introduce single-photon single-particle tracking (SP 2 T), a framework that bypasses localization and linking by estimating particle numbers and trajectories directly by jointly considering 1-bit image stacks. While cameras capable of microsecond-scale exposures, typically based on scientific CMOS (sCMOS) sensors or single-photon detectors (SPDs), are increasingly central to this effort, in this work, we focus on single-photon avalanche diode (SPAD). Single-photon detector (SPD) arrays offer microsecond exposures over large fields of view (512×512 pixels). SP 2 T accounts for detector-specific artifacts such as hot and cold pixels and is validated with programmed fluorescent bead trajectories and biological systems (aerolysin and ganglioside). These experiments, in addition to simulations, reveal that analysis performed with longer exposures can bias diffusion coefficient estimates (up to 70% for particles with diffusion coefficients of 5 µ m 2 /s) and distort jump-distance distributions, underscoring the need for photon-by-photon tracking in fast-diffusion regimes. Moreover, SP 2 T delivers substantial computational gains—achieving more than a 50-fold GPU speedup over CPU-based likelihood tracking methods that assume continuous intensity, when compared on datasets with the same frame size and number of frames. Together, these advances establish SP 2 T as a robust, data-efficient solution for unbiased particle tracking with millisecond-to-microsecond temporal resolution.
- Open Access
Lumen charge governs gated ion transport in β-barrel nanopores
β-barrel nanopores are involved in crucial biological processes, from ATP export in mitochondria to bacterial resistance, and represent a promising platform for emerging sequencing technologies. However, in contrast to ion channels, the understanding of the fundamental principles governing ion transport through these nanopores remains in its early stages. In this study, we integrate experimental, numerical, and theoretical approaches to elucidate ion transport mechanisms in these biological nanopores. We identify and characterise two distinct nonlinear phenomena: open-pore rectification and gating. Through extensive mutation analysis of aerolysin nanopores, we demonstrate that open-pore rectification is caused by ionic accumulation driven by the distribution of lumen charges. Additionally, we provide converging evidence suggesting that gating is controlled by electric fields dissociating counterions from lumen charges, promoting local structural deformations. Our findings establish a rigorous framework for the characterisation and understanding of biological ion transport processes, enabling the design of adaptable biosensors. We illustrate this by optimizing an aerolysin mutant for computing applications, paving the way for novel nanofluidic technologies.
Open AccessLumen charge governs gated ion transport in β-barrel nanopores
β-barrel nanopores are involved in crucial biological processes, from ATP export in mitochondria to bacterial resistance, and represent a promising platform for emerging sequencing technologies. However, in contrast to ion channels, the understanding of the fundamental principles governing ion transport through these nanopores remains in its early stages. In this study, we integrate experimental, numerical, and theoretical approaches to elucidate ion transport mechanisms in these biological nanopores. We identify and characterise two distinct nonlinear phenomena: open-pore rectification and gating. Through extensive mutation analysis of aerolysin nanopores, we demonstrate that open-pore rectification is caused by ionic accumulation driven by the distribution of lumen charges. Additionally, we provide converging evidence suggesting that gating is controlled by electric fields dissociating counterions from lumen charges, promoting local structural deformations. Our findings establish a rigorous framework for the characterisation and understanding of biological ion transport processes, enabling the design of adaptable biosensors. We illustrate this by optimizing an aerolysin mutant for computing applications, paving the way for novel nanofluidic technologies.
- Open Access
Wide-field fluorescence lifetime imaging of single molecules with a gated single-photon camera
Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool to discriminate fluorescent molecules or probe their nanoscale environment. Traditionally, FLIM uses time-correlated single-photon counting (TCSPC), which is precise but intrinsically low-throughput due to its dependence on point detectors. Although time-gated cameras have demonstrated the potential for high-throughput FLIM in bright samples with dense labeling, their use in single-molecule microscopy has not been explored extensively. Here, we report fast and accurate single-molecule FLIM with a commercial time-gated single-photon camera. Our optimized acquisition scheme achieves single-molecule lifetime measurements with a precision only about three times less than TCSPC, while imaging with a large number of pixels (512×512) allowing for the spatial multiplexing of over 3000 molecules. With this approach, we demonstrate parallelized lifetime measurements of large numbers of labeled pore-forming proteins on supported lipid bilayers, and temporal single-molecule Förster resonance energy transfer measurements at 5-25 Hz. This method holds considerable promise for the advancement of multi-target single-molecule localization microscopy and biopolymer sequencing.
Open AccessWide-field fluorescence lifetime imaging of single molecules with a gated single-photon camera
Fluorescence lifetime imaging microscopy (FLIM) is a powerful tool to discriminate fluorescent molecules or probe their nanoscale environment. Traditionally, FLIM uses time-correlated single-photon counting (TCSPC), which is precise but intrinsically low-throughput due to its dependence on point detectors. Although time-gated cameras have demonstrated the potential for high-throughput FLIM in bright samples with dense labeling, their use in single-molecule microscopy has not been explored extensively. Here, we report fast and accurate single-molecule FLIM with a commercial time-gated single-photon camera. Our optimized acquisition scheme achieves single-molecule lifetime measurements with a precision only about three times less than TCSPC, while imaging with a large number of pixels (512×512) allowing for the spatial multiplexing of over 3000 molecules. With this approach, we demonstrate parallelized lifetime measurements of large numbers of labeled pore-forming proteins on supported lipid bilayers, and temporal single-molecule Förster resonance energy transfer measurements at 5-25 Hz. This method holds considerable promise for the advancement of multi-target single-molecule localization microscopy and biopolymer sequencing.
- Top Cited Papers
- 19 September 2024
- Published by Springer Nature in Nature Reviews Methods Primers
- Vol. 4 (1) , 1-18
Nanofluidics
- 19 September 2024
- Published by Springer Nature in Nature Reviews Methods Primers
- Vol. 4 (1) , 1-18
Top Cited PapersNanofluidics
- Top Cited PapersOpen Access
- 19 March 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (4) , 271-278
Nanofluidic logic with mechano–ionic memristive switches
Neuromorphic systems are typically based on nanoscale electronic devices, but nature relies on ions for energy-efficient information processing. Nanofluidic memristive devices could thus potentially be used to construct electrolytic computers that mimic the brain down to its basic principles of operation. Here we report a nanofluidic device that is designed for circuit-scale in-memory processing. The device, which is fabricated using a scalable process, combines single-digit nanometric confinement and large entrance asymmetry and operates on the second timescale with a conductance ratio in the range of 9 to 60. In operando optical microscopy shows that the memory capabilities are due to the reversible formation of liquid blisters that modulate the conductance of the device. We use these mechano–ionic memristive switches to assemble logic circuits composed of two interactive devices and an ohmic resistor.
- 19 March 2024
- Published by Springer Nature in Nature Electronics
- Vol. 7 (4) , 271-278
Top Cited PapersOpen AccessNanofluidic logic with mechano–ionic memristive switches
Neuromorphic systems are typically based on nanoscale electronic devices, but nature relies on ions for energy-efficient information processing. Nanofluidic memristive devices could thus potentially be used to construct electrolytic computers that mimic the brain down to its basic principles of operation. Here we report a nanofluidic device that is designed for circuit-scale in-memory processing. The device, which is fabricated using a scalable process, combines single-digit nanometric confinement and large entrance asymmetry and operates on the second timescale with a conductance ratio in the range of 9 to 60. In operando optical microscopy shows that the memory capabilities are due to the reversible formation of liquid blisters that modulate the conductance of the device. We use these mechano–ionic memristive switches to assemble logic circuits composed of two interactive devices and an ohmic resistor.
- Open Access
- 20 February 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-8
Open-source microscope add-on for structured illumination microscopy
Super-resolution techniques expand the abilities of researchers who have the knowledge and resources to either build or purchase a system. This excludes the part of the research community without these capabilities. Here we introduce the openSIM add-on to upgrade existing optical microscopes to Structured Illumination super-resolution Microscopes (SIM). The openSIM is an open-hardware system, designed and documented to be easily duplicated by other laboratories, making super-resolution modality accessible to facilitate innovative research. The add-on approach gives a performance improvement for pre-existing lab equipment without the need to build a completely new system.
- 20 February 2024
- Published by Springer Nature in Nature Communications
- Vol. 15 (1) , 1-8
Open AccessOpen-source microscope add-on for structured illumination microscopy
Super-resolution techniques expand the abilities of researchers who have the knowledge and resources to either build or purchase a system. This excludes the part of the research community without these capabilities. Here we introduce the openSIM add-on to upgrade existing optical microscopes to Structured Illumination super-resolution Microscopes (SIM). The openSIM is an open-hardware system, designed and documented to be easily duplicated by other laboratories, making super-resolution modality accessible to facilitate innovative research. The add-on approach gives a performance improvement for pre-existing lab equipment without the need to build a completely new system.