Yusei Otaka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yusei Otaka has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Atsushi Iwawaki
Division of Forensic Odontology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan
4 shared publications Shinji Kito
Division of Dental Radiology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan
4 shared publicationsNobutoshi Takahashi
Division of Dental Radiology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan
3 shared publicationsNoriyoshi Shiba
Division of Dental Radiology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan
3 shared publicationsAkihiro Ochiai
Division of Forensic Odontology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan
2 shared publicationsHideki Saka
Division of Forensic Odontology, Department of Diagnostic and Therapeutic Sciences, Meikai University School of Dentistry, Saitama, Japan; Forensic Odontology Center, Meikai University School of Dentistry, Saitama, Japan
2 shared publications
Latest Publications
- 6 August 2025
- Published by Elsevier in Journal of Oral Biosciences
- Vol. 67 (3) , 100685
Sex determination and age estimation method using the trabecular structure of the third cervical vertebral body by head and neck CT in Japanese adults
- 6 August 2025
- Published by Elsevier in Journal of Oral Biosciences
- Vol. 67 (3) , 100685
Sex determination and age estimation method using the trabecular structure of the third cervical vertebral body by head and neck CT in Japanese adults
- 28 December 2024
- Published by Elsevier in Journal of Oral Biosciences
- Vol. 67 (1) , 100608
Sex determination method using the third cervical vertebral body by head and neck CT
- 28 December 2024
- Published by Elsevier in Journal of Oral Biosciences
- Vol. 67 (1) , 100608
Sex determination method using the third cervical vertebral body by head and neck CT
- Open Access
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of Indian Academy of Oral Medicine and Radiology
- Vol. 36 (4) , 381-386
Experimental Study of the Reduction of the Dose to the Radiographic Operator Using an Additional Rectangular Collimator and Detector Holder During Handheld Exposure with a Portable Intraoral X-Ray Device
Background: Use of a rectangular collimator and a detector holder reduces the patient’s dose in intraoral radiography; however, their quantitative effects on reducing the operator’s dose are unknown. Objectives: This study aimed to evaluate the reduction in the operator’s dose when using a rectangular collimator and a detector holder during handheld exposure with a portable intraoral X-ray device. Materials and Methods: Dose was measured using a cylindrical polymethylmethacrylate phantom and two semiconductor dosimeters. Stray radiation from the phantom and the X-ray device was measured at 15-degree intervals in horizontal and vertical circles with radii of 50 cm and 100 cm from the center of the phantom. Doses were compared with and without the additional rectangular collimator and the detector holder. Results: Use of the additional rectangular collimator and the detector holder reduced the operator’s dose to one-eighth and one-fifth, respectively, of the dose when these items were not used. Conclusion: Using an additional rectangular collimator and a detector holder appears effective for reducing the dose to the radiographic operator during handheld exposure with a portable intraoral X-ray device and could be applied to situations such as dental home health care and person identification in forensic dentistry.
- 1 October 2024
- Published by Wolters Kluwer Health in Journal of Indian Academy of Oral Medicine and Radiology
- Vol. 36 (4) , 381-386
Open AccessExperimental Study of the Reduction of the Dose to the Radiographic Operator Using an Additional Rectangular Collimator and Detector Holder During Handheld Exposure with a Portable Intraoral X-Ray Device
Background: Use of a rectangular collimator and a detector holder reduces the patient’s dose in intraoral radiography; however, their quantitative effects on reducing the operator’s dose are unknown. Objectives: This study aimed to evaluate the reduction in the operator’s dose when using a rectangular collimator and a detector holder during handheld exposure with a portable intraoral X-ray device. Materials and Methods: Dose was measured using a cylindrical polymethylmethacrylate phantom and two semiconductor dosimeters. Stray radiation from the phantom and the X-ray device was measured at 15-degree intervals in horizontal and vertical circles with radii of 50 cm and 100 cm from the center of the phantom. Doses were compared with and without the additional rectangular collimator and the detector holder. Results: Use of the additional rectangular collimator and the detector holder reduced the operator’s dose to one-eighth and one-fifth, respectively, of the dose when these items were not used. Conclusion: Using an additional rectangular collimator and a detector holder appears effective for reducing the dose to the radiographic operator during handheld exposure with a portable intraoral X-ray device and could be applied to situations such as dental home health care and person identification in forensic dentistry.
- Open Access
- 31 October 2023
- Published by International Institute of Anticancer Research in In Vivo
- Vol. 37 (6) , 2464-2472
UVC-Protective Activity of Lemongrass Among 12 Fat-soluble Herbal Extracts: Rapid Decay Due to Cytotoxicity
Background/Aim: The COVID-19 pandemic led to the rapid spread of the use of ultraviolet C (UVC) sterilizers in many public facilities. Considering the harmful effects of prolonged exposure to UVC, manufacturing of safe skin care products is an important countermeasure. In continuation of our recent study of water-soluble herbal extracts, the present study aimed at searching for anti-UVC components from fat-soluble herbal extracts. Materials and Methods: Human dermal fibroblast and melanoma cells were exposed to UVC (1.193 W/m2) for 3 min. Viable cell number was determined by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. Cell-cycle analysis was performed using a cell sorter. UVC-protective activity was quantified by the selective index (SI), i.e., the ratio of the 50% cytotoxic concentration for unirradiated cells to the concentration that restored viability of UVC-treated cells by 50%. Results: Only lemongrass extract, among 12 fat-soluble herbal extracts, showed significant anti-UVC activity, comparable to that of lignified materials and tannins, but exceeding that of N-acetyl-L-cysteine and resveratrol. Lemongrass extract was highly cytotoxic, producing a subG1 cell population. During prolonged incubation in culture medium, the anti-UVC activity of lemongrass extract, sodium ascorbate and vanillic acid declined with an approximate half-life of <0.7, 5.4-21.6, and 27.8-87.0 h, respectively. Conclusion: Removal of cytotoxic principle(s) from lemongrass extract is crucial to producing long-lasting UVC-protective effects.
- 31 October 2023
- Published by International Institute of Anticancer Research in In Vivo
- Vol. 37 (6) , 2464-2472
Open AccessUVC-Protective Activity of Lemongrass Among 12 Fat-soluble Herbal Extracts: Rapid Decay Due to Cytotoxicity
Background/Aim: The COVID-19 pandemic led to the rapid spread of the use of ultraviolet C (UVC) sterilizers in many public facilities. Considering the harmful effects of prolonged exposure to UVC, manufacturing of safe skin care products is an important countermeasure. In continuation of our recent study of water-soluble herbal extracts, the present study aimed at searching for anti-UVC components from fat-soluble herbal extracts. Materials and Methods: Human dermal fibroblast and melanoma cells were exposed to UVC (1.193 W/m2) for 3 min. Viable cell number was determined by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay. Cell-cycle analysis was performed using a cell sorter. UVC-protective activity was quantified by the selective index (SI), i.e., the ratio of the 50% cytotoxic concentration for unirradiated cells to the concentration that restored viability of UVC-treated cells by 50%. Results: Only lemongrass extract, among 12 fat-soluble herbal extracts, showed significant anti-UVC activity, comparable to that of lignified materials and tannins, but exceeding that of N-acetyl-L-cysteine and resveratrol. Lemongrass extract was highly cytotoxic, producing a subG1 cell population. During prolonged incubation in culture medium, the anti-UVC activity of lemongrass extract, sodium ascorbate and vanillic acid declined with an approximate half-life of <0.7, 5.4-21.6, and 27.8-87.0 h, respectively. Conclusion: Removal of cytotoxic principle(s) from lemongrass extract is crucial to producing long-lasting UVC-protective effects.
- 31 August 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (19) , 2349-2355
Stray radiation dose reduction using a backscatter shield and a rectangular collimator for a handheld intraoral X-ray unit
The objective of this study was to study the dose reduction effect on occupational exposure of operators and public exposure other than operators when a backscatter shield and a rectangular collimator are used in conjunction with a handheld intraoral X-ray unit. The occupational exposure was reduced to 40% when the backscatter shield was attached to the cone-tip, to 13% when the rectangular collimator was attached and to 7.7% when the backscatter shield and rectangular collimator were used together. On the other hand, the public exposure was reduced to 20% when the rectangular collimator was attached, but the backscatter shield was not effective in reducing the public exposure. Attaching a backscatter shield is effective in reducing the occupational exposure, and a rectangular aperture is effective in reducing the occupational exposure, as well as the public exposure.
- 31 August 2023
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 199 (19) , 2349-2355
Stray radiation dose reduction using a backscatter shield and a rectangular collimator for a handheld intraoral X-ray unit
The objective of this study was to study the dose reduction effect on occupational exposure of operators and public exposure other than operators when a backscatter shield and a rectangular collimator are used in conjunction with a handheld intraoral X-ray unit. The occupational exposure was reduced to 40% when the backscatter shield was attached to the cone-tip, to 13% when the rectangular collimator was attached and to 7.7% when the backscatter shield and rectangular collimator were used together. On the other hand, the public exposure was reduced to 20% when the rectangular collimator was attached, but the backscatter shield was not effective in reducing the public exposure. Attaching a backscatter shield is effective in reducing the occupational exposure, and a rectangular aperture is effective in reducing the occupational exposure, as well as the public exposure.
- 30 June 2020
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 13 (3) , 312-320
Reduction of operator exposure by rectangular collimation in portable intraoral radiography
Portable intraoral X-ray units are frequently used for home-visit dental treatment and personal dental identification. Therefore, the reduction of operator exposure is crucial. Rectangular collimation is effective at reducing patient exposure and operator exposure; however, its effects are not known. We investigated the reduction of operator exposure through rectangular collimation by measuring the backscattered dose in relation to the operator exposure dose. Using a portable intraoral X-ray unit, a head phantom for CT dose measurement as the object, a dosimeter, and stainless-steel rectangular collimator, a 1-cm ambient dose equivalent was measured in intervals of 15° in horizontal and vertical planes with the radii of 50 and 100 cm. The backscattered dose decreased to approximately one-third when a rectangular collimator was attached to the cone tip. This may have been due to the reduction of the volume of scattered X-rays generated in the phantom by rectangular collimation. We clarified that rectangular collimation is effective at reducing the operator exposure and is useful for protecting the operators of portable intraoral X-ray units during home-visit dental treatment and personal dental identification.
- 30 June 2020
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 13 (3) , 312-320
Reduction of operator exposure by rectangular collimation in portable intraoral radiography
Portable intraoral X-ray units are frequently used for home-visit dental treatment and personal dental identification. Therefore, the reduction of operator exposure is crucial. Rectangular collimation is effective at reducing patient exposure and operator exposure; however, its effects are not known. We investigated the reduction of operator exposure through rectangular collimation by measuring the backscattered dose in relation to the operator exposure dose. Using a portable intraoral X-ray unit, a head phantom for CT dose measurement as the object, a dosimeter, and stainless-steel rectangular collimator, a 1-cm ambient dose equivalent was measured in intervals of 15° in horizontal and vertical planes with the radii of 50 and 100 cm. The backscattered dose decreased to approximately one-third when a rectangular collimator was attached to the cone tip. This may have been due to the reduction of the volume of scattered X-rays generated in the phantom by rectangular collimation. We clarified that rectangular collimation is effective at reducing the operator exposure and is useful for protecting the operators of portable intraoral X-ray units during home-visit dental treatment and personal dental identification.