Charles E. Penney
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Charles E. Penney has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Angelo Gattozzi
Center for Electromechanics, The University of Texas at Austin, Austin, TX, USA
2 shared publications - Robert E. Hebner
Center for Electromechanics, University of Texas at Austin, Austin, TX 78758, USA
2 shared publications - Xianyong Feng
Center for Electromechanics, University of Texas System, 7067 Austin, Texas United States 78701-2982
2 shared publications - Chen Zhang
State Key Laboratory of Electrical Insulation and Power Equipment, Xian Jiaotong University, Xian, China
1 shared publication - Gary J. Hill
The University of Texas at Austin
1 shared publication Herman Kriel
University of Texas at Austin
1 shared publication
Latest Publications
- 31 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (6) , 958-967
Development of a Fault Detection and Localization Algorithm for Photovoltaic Systems
Photovoltaic systems provide electrical power with reduced emissions at competitive costs compared to legacy systems. A low or medium voltage dc distribution system is usually used for solar integration. In dc systems, parallel and series arc faults are a safety concern. Thus, reliable and timely detection and mitigation of arc faults are critical. DC arc detection methods typically use time or frequency spectrum variations of the circuit current or voltage to differentiate the arcing event from other system events. Since practical systems include power electronics and maximum-power-point tracking, any detection scheme must perform robustly in the electrical environment that these components establish in the dc power system. A capacitor placed in parallel with the main system is an effective sensor for series arc fault detection and localization applicable in this complex electrical environment. This article shows that the analysis of the amplitude, polarity, and spectrum characteristics of the capacitor current and voltage resulting from perturbations caused by the arc provides an effective method to identify and localize faults. The detection accuracy of the proposed approach is 98.3% and the localization accuracy rate is 100% for the correctly detected faults.
- 31 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 13 (6) , 958-967
Development of a Fault Detection and Localization Algorithm for Photovoltaic Systems
Photovoltaic systems provide electrical power with reduced emissions at competitive costs compared to legacy systems. A low or medium voltage dc distribution system is usually used for solar integration. In dc systems, parallel and series arc faults are a safety concern. Thus, reliable and timely detection and mitigation of arc faults are critical. DC arc detection methods typically use time or frequency spectrum variations of the circuit current or voltage to differentiate the arcing event from other system events. Since practical systems include power electronics and maximum-power-point tracking, any detection scheme must perform robustly in the electrical environment that these components establish in the dc power system. A capacitor placed in parallel with the main system is an effective sensor for series arc fault detection and localization applicable in this complex electrical environment. This article shows that the analysis of the amplitude, polarity, and spectrum characteristics of the capacitor current and voltage resulting from perturbations caused by the arc provides an effective method to identify and localize faults. The detection accuracy of the proposed approach is 98.3% and the localization accuracy rate is 100% for the correctly detected faults.
- Open Access
- 31 December 2020
- Published by MDPI AG in Inventions
- Vol. 6 (1) , 5
Voltage Differential Protection for Series Arc Fault Detection in Low-Voltage DC Systems
Series arc faults are challenging to detect in low-voltage dc (LVDC) distribution systems because, unlike other fault types, series arc faults result in only small changes in the current and voltage waveforms. Though there have been several approaches proposed to detect series arc faults, each approach has its requirements and limitations. A step change in the current and voltage waveforms at the arc inception is one of the characteristic signatures of these faults that can be extracted without requiring one to sample the waveforms at a very high frequency. This characteristic feature is utilized to present a novel approach based on voltage differential protection to detect series arc faults in LVDC systems. The proposed method is demonstrated using an embedded controller and experimental data that emulate a hardware-in-the-loop (HIL) test environment. The successful detection of series arc faults on two sets of series arc fault experimental data validated the approach. The results presented also illustrate the computational feasibility in implementing the approach in a real-time environment using an embedded controller. In addition, the paper discusses the robustness of the approach to load changes and loss of time synchronization between measurements at the two terminals of the line.
- 31 December 2020
- Published by MDPI AG in Inventions
- Vol. 6 (1) , 5
Open AccessVoltage Differential Protection for Series Arc Fault Detection in Low-Voltage DC Systems
Series arc faults are challenging to detect in low-voltage dc (LVDC) distribution systems because, unlike other fault types, series arc faults result in only small changes in the current and voltage waveforms. Though there have been several approaches proposed to detect series arc faults, each approach has its requirements and limitations. A step change in the current and voltage waveforms at the arc inception is one of the characteristic signatures of these faults that can be extracted without requiring one to sample the waveforms at a very high frequency. This characteristic feature is utilized to present a novel approach based on voltage differential protection to detect series arc faults in LVDC systems. The proposed method is demonstrated using an embedded controller and experimental data that emulate a hardware-in-the-loop (HIL) test environment. The successful detection of series arc faults on two sets of series arc fault experimental data validated the approach. The results presented also illustrate the computational feasibility in implementing the approach in a real-time environment using an embedded controller. In addition, the paper discusses the robustness of the approach to load changes and loss of time synchronization between measurements at the two terminals of the line.
- 1 September 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8449, 84491K-84491K-12
Use of failure modes and effects analysis in design of the tracker system for the HET wide-field upgrade
- 1 September 2012
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8449, 84491K-84491K-12
Use of failure modes and effects analysis in design of the tracker system for the HET wide-field upgrade