JGJianxin Gao

Jianxin Gao

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jianxin Gao has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-Resolution Photonic Temperature Measurement System Based on Frequency Locking of Microring Resonator

    by Jin Wang, Cheng Zhang, Jianxin Gao, Shuai Wan, Chunhua Dong, Yang Shen, Yijie Pan, Qina Han, Kunli Zhou, Jifeng Qu

    In this letter, we present a high-resolution temperature measurement method utilizing Pound-Drever-Hall (PDH) frequency locking with a silicon nitride (Si 3 N 4 ) microring resonator as a photonic thermometer. The temperature response at various intervals demonstrates a measurement resolution less than 1 mK. Through the calculations of the thermal noise floor and frequency linewidth of the Si 3 N 4 microring resonator, we establish the theoretical resolution limit of the frequency locking method to be 41 μK at 1 Hz measurement frequency. This precise and stable temperature measurement technique holds immense potential as an in-situ thermometers for diverse quantum chips, thus accelerating the research progress of chip-level quantum metrology.


  • Open Access

    An On-Chip Silicon Photonics Thermometer with Milli-Kelvin Resolution

    by Jin Wang, Yijie Pan, Jianxin Gao, Cheng Zhang, Zhier Qu, Tongtong Xu, Yang Shen, Jifeng Qu

    Photonic-based thermometers have been attracting intense research interest as a potential alternative to traditional electrical thermometers due to their physical and chemical stability and immunity to electromagnetic interference. However, due to the high requirements for the stability of the laser source, the existing studies on resolution are only theoretical predictions and do not include real-measured results. In this paper, we report on the fabrication and characterization of an on-chip silicon whispering-gallery-mode (WGM) ring resonator thermometer. The strip grating and the ring structure were fabricated on the silicon-on-insulator (SOI) substrate by two-step etching. The quality-factor (Q-factor), temperature sensitivity, and measurement range of the packaged device were 21,400, 42 pm/K, and 150 K, respectively. The real-measured temperature resolution of 2.9 mK was achieved by virtue of the power and polarization stabilization of the laser source.