Suhyeon Park
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Suhyeon Park has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Jae Su Kwak
School of Aerospace and Mechanical Engineering, Korea Aerospace University, Go-yang, Korea
4 shared publications - Woojun Kim
School of Aerospace and Mechanical Engineering, Korea Aerospace University, 76, Hanggongdaehak-ro, Deogyang-gu, Goyang-si 10540, Gyeonggi-do, Republic of Korea
3 shared publications - Taesoon Kim
Environment and Energy Research Laboratory Research Institute of Industrial Science and Technology Gwangyang Korea
2 shared publications Won Seok Lim
2 shared publicationsYoung Jun Kang
2 shared publicationsChangsoo Kang
1 shared publication
Latest Publications
- Open Access
- 19 June 2026
- Published by Elsevier in Results in Engineering
- Vol. 31
Numerical study on internal flow uniformity and pressure characteristics of segmented porous transport layers for alkaline water electrolysis
- 19 June 2026
- Published by Elsevier in Results in Engineering
- Vol. 31
Open AccessNumerical study on internal flow uniformity and pressure characteristics of segmented porous transport layers for alkaline water electrolysis
- 30 January 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 400
Ionic wind characteristics of electromagnetic plasma micro-actuator
- 30 January 2026
- Published by Elsevier in Sensors and Actuators A: Physical
- Vol. 400
Ionic wind characteristics of electromagnetic plasma micro-actuator
- Open Access
Numerical Analysis of Factors Affecting NOx Emissions in Hydrogen-Fueled Micromix Combustors
Micromix combustion is a promising approach to addressing issues such as flashback, combustion instability, and nitrogen oxide (NOx) emissions in hydrogen-fueled gas turbines. In this study, a numerical analysis was conducted to investigate key factors influencing NOx emissions in a lab-scale micromix combustor under atmospheric pressure and room temperature. The effects of air flow rate, equivalence ratio, and combustor component surface temperature on NOx formation were systematically evaluated. The results show that increasing the air and hydrogen flow rates at a constant equivalence ratio reduced NOx emissions due to shorter residence times. In addition, higher surface temperatures of combustor components increased flame temperatures and NOx production. Lastly, high equivalence ratios led to partial flame merging, increasing NOx emissions. These findings highlight that the efficient cooling of combustor components and proper selection of air flow rate and equivalence ratio are critical to minimizing NOx emissions in micromix combustors. The study provides design and operational guidelines for the future development of hydrogen-fueled gas turbines.
Open AccessNumerical Analysis of Factors Affecting NOx Emissions in Hydrogen-Fueled Micromix Combustors
Micromix combustion is a promising approach to addressing issues such as flashback, combustion instability, and nitrogen oxide (NOx) emissions in hydrogen-fueled gas turbines. In this study, a numerical analysis was conducted to investigate key factors influencing NOx emissions in a lab-scale micromix combustor under atmospheric pressure and room temperature. The effects of air flow rate, equivalence ratio, and combustor component surface temperature on NOx formation were systematically evaluated. The results show that increasing the air and hydrogen flow rates at a constant equivalence ratio reduced NOx emissions due to shorter residence times. In addition, higher surface temperatures of combustor components increased flame temperatures and NOx production. Lastly, high equivalence ratios led to partial flame merging, increasing NOx emissions. These findings highlight that the efficient cooling of combustor components and proper selection of air flow rate and equivalence ratio are critical to minimizing NOx emissions in micromix combustors. The study provides design and operational guidelines for the future development of hydrogen-fueled gas turbines.
- 5 May 2025
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 215
Effect of an inlet keyhole slot geometry on crossflow-fed-film cooling hole
- 5 May 2025
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 215
Effect of an inlet keyhole slot geometry on crossflow-fed-film cooling hole
- 18 March 2024
- Published by Elsevier in Aerospace Science and Technology
- Vol. 148
Improvement of labyrinth seal performance using the partial honeycomb lands
- 18 March 2024
- Published by Elsevier in Aerospace Science and Technology
- Vol. 148
Improvement of labyrinth seal performance using the partial honeycomb lands
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (1)
Suspension of a point-mass-loaded filament in non-uniform flows: Passive dynamics of a ballooning spider
Spiders utilize their fine silk fibers for their aerial dispersal, known as ballooning. With this method, spiders can disperse hundreds of kilometers, reaching as high as 4.5 km. However, the passive dynamics of a ballooning model (a highly flexible filament and a spider body at the end of it) are not well understood. Here, we introduce a bead–spring model that takes into account the anisotropic drag of a fiber to investigate the passive dynamics by the various non-uniform flows: (i) a shear flow, (ii) a periodic vortex flow field, and (iii) a homogeneous turbulent flow. For the analysis of the wide range of parameters, we defined a dimensionless parameter, which is called “a ballooning number.” The ballooning number is defined as the ratio of Stokes’ fluid-dynamic force on a fiber by the non-uniform flow field to the gravitational force of a body. Our simulations show that the present model in a homogeneous turbulent flow exhibits the biased characteristic of slow settling with increasing turbulence. Upon investigating this phenomenon for a shear flows, it was found that the drag anisotropy of the filament structure is the main cause of the slow settling. Particularly, the cause of slow settling speed lies not only in the deformed geometrical shape but also in its generation of fluid-dynamic force in a non-uniform flow. Additionally, we found that the ballooning structure could become trapped in a vortex flow. These results help deepen our understanding of the passive dynamics of spiders ballooning in the atmospheric boundary layer.
- 1 January 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (1)
Open AccessSuspension of a point-mass-loaded filament in non-uniform flows: Passive dynamics of a ballooning spider
Spiders utilize their fine silk fibers for their aerial dispersal, known as ballooning. With this method, spiders can disperse hundreds of kilometers, reaching as high as 4.5 km. However, the passive dynamics of a ballooning model (a highly flexible filament and a spider body at the end of it) are not well understood. Here, we introduce a bead–spring model that takes into account the anisotropic drag of a fiber to investigate the passive dynamics by the various non-uniform flows: (i) a shear flow, (ii) a periodic vortex flow field, and (iii) a homogeneous turbulent flow. For the analysis of the wide range of parameters, we defined a dimensionless parameter, which is called “a ballooning number.” The ballooning number is defined as the ratio of Stokes’ fluid-dynamic force on a fiber by the non-uniform flow field to the gravitational force of a body. Our simulations show that the present model in a homogeneous turbulent flow exhibits the biased characteristic of slow settling with increasing turbulence. Upon investigating this phenomenon for a shear flows, it was found that the drag anisotropy of the filament structure is the main cause of the slow settling. Particularly, the cause of slow settling speed lies not only in the deformed geometrical shape but also in its generation of fluid-dynamic force in a non-uniform flow. Additionally, we found that the ballooning structure could become trapped in a vortex flow. These results help deepen our understanding of the passive dynamics of spiders ballooning in the atmospheric boundary layer.
- Open Access
- 31 December 2023
- Published by Korean Society of Health Promotion and Disease Prevention in Korean Journal of Health Promotion
- Vol. 23 (4) , 217-225
Comparison of Heat Treatments by Floor Heating and Fan Heating for Bed Bug Control
Background: Non-chemical methods are as important as pesticides to control bed bugs. The most effective method is heat treatment. Underfloor heating is widely used in residential buildings in Korea, and the benefits of floor heating can be utilized in heat treatment for bed bug control.Methods: Simulations of indoor air flow and heat transfer were performed to compare and analyze the temperature distributions with different heating methods for bed bug control using floor heating and fan heater methods.Results: Even though the average indoor temperature of floor heating was lower, it was more uniform with floor heating than that of fan heating under the assumed conditions. Local cold spots disappeared with the floor heating method.Conclusions: It was confirmed that floor heating has advantages over fan heating to achive uniform high temperatures during heat treatment for exterminating bed bugs.
- 31 December 2023
- Published by Korean Society of Health Promotion and Disease Prevention in Korean Journal of Health Promotion
- Vol. 23 (4) , 217-225
Open AccessComparison of Heat Treatments by Floor Heating and Fan Heating for Bed Bug Control
Background: Non-chemical methods are as important as pesticides to control bed bugs. The most effective method is heat treatment. Underfloor heating is widely used in residential buildings in Korea, and the benefits of floor heating can be utilized in heat treatment for bed bug control.Methods: Simulations of indoor air flow and heat transfer were performed to compare and analyze the temperature distributions with different heating methods for bed bug control using floor heating and fan heater methods.Results: Even though the average indoor temperature of floor heating was lower, it was more uniform with floor heating than that of fan heating under the assumed conditions. Local cold spots disappeared with the floor heating method.Conclusions: It was confirmed that floor heating has advantages over fan heating to achive uniform high temperatures during heat treatment for exterminating bed bugs.
- Open Access
Numerical Study on Combustion-Driven Jet Actuation for Aerodynamic Control of Airfoil Flows
In this study, a numerical investigation is conducted on combustion-driven pulsed-jet actuation to control the flow around a lifting surface. Based on relevant experimental measurements and computations, high-speed jets are generated from the impulsive variation in pressure at the actuator boundary. A supersonic jet flow is momentarily generated by combustion in a reaction chamber of the actuator, and the flow interacts with the external flow around the lifting surface and alters the aerodynamic characteristics. The computational results indicate that the flow control performance of the jet actuation is significant at a high-incidence angle of attack, such as beyond the stall angle, whereas the impact is minimal at low angles of attack, such as in the linear lift region. Repetitive jet actuation can produce additional momentum to the external flow and alters the pressure distribution on the suction surface, particularly downstream of the actuator location. This pressure variation from the actuation yields an additional lift force on the lifting surface and reduces the amplitude of the aerodynamic moment at a given angle of attack, thus enhancing the aerodynamic performance of the airfoil.
Open AccessNumerical Study on Combustion-Driven Jet Actuation for Aerodynamic Control of Airfoil Flows
In this study, a numerical investigation is conducted on combustion-driven pulsed-jet actuation to control the flow around a lifting surface. Based on relevant experimental measurements and computations, high-speed jets are generated from the impulsive variation in pressure at the actuator boundary. A supersonic jet flow is momentarily generated by combustion in a reaction chamber of the actuator, and the flow interacts with the external flow around the lifting surface and alters the aerodynamic characteristics. The computational results indicate that the flow control performance of the jet actuation is significant at a high-incidence angle of attack, such as beyond the stall angle, whereas the impact is minimal at low angles of attack, such as in the linear lift region. Repetitive jet actuation can produce additional momentum to the external flow and alters the pressure distribution on the suction surface, particularly downstream of the actuator location. This pressure variation from the actuation yields an additional lift force on the lifting surface and reduces the amplitude of the aerodynamic moment at a given angle of attack, thus enhancing the aerodynamic performance of the airfoil.
- Open Access
Mass Flow Function Correlation for Solid and Honeycomb Land Labyrinth Seals including Fin Front Angle, Clearance, Fin Number and Honeycomb Geometry
In this study, the effects of several geometry factors (fin front angle, clearance, number of fins, and honeycomb cell diameter and depth) on the mass flow function of solid and honeycomb land were studied experimentally. The fin front angle considered in the experiment ranged from 60 to 90 degrees, the number of fins was varied between two and three, and the diameter and depth of the honeycomb cell ranged from 1.33 to 4.00 times and 8.08 to 13.08 times the thickness of the fin tip, respectively. The experimental results showed that the mass flow function decreased as the number of fins increased for the solid land labyrinth seal, and the mass flow function increased as the clearance increased. A fin front angle of 60 degrees was found to have the minimum mass flow function. For the honeycomb land labyrinth seal, the mass flow function decreased as the number of fins increased, and the effect of the cell depth was shown to be insignificant compared to the effect of the cell diameter. The effects of cell diameter and cell depth on the mass flow function depended on the conditions of other variables. In addition, the correlation equations of the mass flow functions of the solid land and honeycomb land labyrinth seals are presented based on the experimental results, which represent the effects of the fin front angle, clearance, pressure ratio, and diameter and depth of the honeycomb cell. The correlation equation for the solid land labyrinth seal had an value of 0.9822, while the correlation equation for honeycomb land had an value of 0.9621.Open AccessMass Flow Function Correlation for Solid and Honeycomb Land Labyrinth Seals including Fin Front Angle, Clearance, Fin Number and Honeycomb Geometry
In this study, the effects of several geometry factors (fin front angle, clearance, number of fins, and honeycomb cell diameter and depth) on the mass flow function of solid and honeycomb land were studied experimentally. The fin front angle considered in the experiment ranged from 60 to 90 degrees, the number of fins was varied between two and three, and the diameter and depth of the honeycomb cell ranged from 1.33 to 4.00 times and 8.08 to 13.08 times the thickness of the fin tip, respectively. The experimental results showed that the mass flow function decreased as the number of fins increased for the solid land labyrinth seal, and the mass flow function increased as the clearance increased. A fin front angle of 60 degrees was found to have the minimum mass flow function. For the honeycomb land labyrinth seal, the mass flow function decreased as the number of fins increased, and the effect of the cell depth was shown to be insignificant compared to the effect of the cell diameter. The effects of cell diameter and cell depth on the mass flow function depended on the conditions of other variables. In addition, the correlation equations of the mass flow functions of the solid land and honeycomb land labyrinth seals are presented based on the experimental results, which represent the effects of the fin front angle, clearance, pressure ratio, and diameter and depth of the honeycomb cell. The correlation equation for the solid land labyrinth seal had an value of 0.9822, while the correlation equation for honeycomb land had an value of 0.9621.