Maísa Carnietto
Research Subjects
Research Interests
Maísa Carnietto has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Joel Ferreira Santiago Junior
Universidade de São Paulo, Brasil
2 shared publications - Ester Alves Ferreira Bordini
Universidade de São Paulo, Brasil
1 shared publication - Fernanda Leal Vieira
Department of Dental Materials and Prosthodontics, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, Brazil
1 shared publication - Hiskell Francine Fernandes Oliveira
Bone Research Lab, Departamento de Biologia Oral, Faculdade de Odontologia de Ribeirão Preto, USP, Universidade de São Paulo, CEP 14040-904 Ribeirão Preto-SP, Brasil
1 shared publication - José R. A. Cerqueira Filho
Military Fire Department of the State of Rio de Janeiro, Rio de Janeiro 20211-030, RJ, Brazil
1 shared publication - Nathália Cristina Bortolozzo
Centro Universitário do Sagrado Coração
1 shared publication
Latest Publications
- Open Access
- 8 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 533
Intraoral Scanning Versus Conventional Methods for Obtaining Full-Arch Implant-Supported Prostheses: A Systematic Review with Meta-Analysis
There is still no consensus on whether intraoral scanning for producing full-arch implant-supported prostheses is effective. Therefore, this systematic review aimed to analyze clinical studies that evaluated intraoral scanning versus conventional impression to obtain rehabilitation of full-arch fixed prostheses and removable. Registration was carried out in the PROSPERO database (CRD: 42020152197). Searches were performed in 11 databases. Review Manager 7.2 (2024) software was used for the quantitative analysis stage (α = 0.05). Bias analysis was conducted using the ROBINS-I and ROB scales, and the certainty of the evidence was evaluated using the GRADE scale. The initial search showed 33,975 abstracts and titles, from which, after applying the inclusion/exclusion criteria, 11 clinical studies were selected. Based on the studies collected, it was observed that there was no difference in the comparison between the digital (DG) and conventional (CG) groups for the following criteria: technical and biological complication rates and marginal bone loss (p > 0.05). The analysis of clinical execution time highlights a notable advantage of the DG over the CG at both scanned patient and implant levels (p < 0.05). Nevertheless, CG achieved fewer retakes than the DG (p < 0.05), demonstrating its reliability in execution. It is concluded that the survival rates of full-arch fixed prostheses produced using intraoral scanning are comparable to those achieved with traditional impression techniques, providing a reliable option for patients. However, further clinical studies are necessary due to the variability in clinical protocols.
- 8 January 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (2) , 533
Open AccessIntraoral Scanning Versus Conventional Methods for Obtaining Full-Arch Implant-Supported Prostheses: A Systematic Review with Meta-Analysis
There is still no consensus on whether intraoral scanning for producing full-arch implant-supported prostheses is effective. Therefore, this systematic review aimed to analyze clinical studies that evaluated intraoral scanning versus conventional impression to obtain rehabilitation of full-arch fixed prostheses and removable. Registration was carried out in the PROSPERO database (CRD: 42020152197). Searches were performed in 11 databases. Review Manager 7.2 (2024) software was used for the quantitative analysis stage (α = 0.05). Bias analysis was conducted using the ROBINS-I and ROB scales, and the certainty of the evidence was evaluated using the GRADE scale. The initial search showed 33,975 abstracts and titles, from which, after applying the inclusion/exclusion criteria, 11 clinical studies were selected. Based on the studies collected, it was observed that there was no difference in the comparison between the digital (DG) and conventional (CG) groups for the following criteria: technical and biological complication rates and marginal bone loss (p > 0.05). The analysis of clinical execution time highlights a notable advantage of the DG over the CG at both scanned patient and implant levels (p < 0.05). Nevertheless, CG achieved fewer retakes than the DG (p < 0.05), demonstrating its reliability in execution. It is concluded that the survival rates of full-arch fixed prostheses produced using intraoral scanning are comparable to those achieved with traditional impression techniques, providing a reliable option for patients. However, further clinical studies are necessary due to the variability in clinical protocols.
- Open Access
- 3 August 2023
- Published by Research, Society and Development in Research, Society and Development
- Vol. 12 (8)
Próteses unitárias fixas implantossuportadas obtidas pelo escaneamento digital: Revisão sistemática
Intraoral scanning is a viable alternative to be used in implant dentistry. However, the use of this technique is more in evidence in recent years and there is a need for a survey of studies to establish an indication protocol for the correct use of scanners and digital molding. Therefore, this study aims to conduct a systematic review with meta-analysis (Cochrane model; PRISMA and PROSPERO: CRD42022313310), in order to analyze the primary studies that evaluated techniques used to obtain moldings in single and partial fixed cases in implant dentistry, using the intraoral scanning system (intervention) compared to the conventional molding system for implant-supported prostheses (comparison). The PubMed/Medline, Cochrane Collaboration, Web of Science and SciELO databases were analyzed using area keywords. The collected data were tabulated and organized qualitatively. Clinical trials were classified according to hierarchy scales. The main results indicated the feasibility of digital scanning when compared to the conventional molding technique for making implant-supported prostheses. In addition, digital flow was associated with shorter clinical procedure time, when compared to conventional molding, greater satisfaction of patients. It is concluded that there is feasibility in the indication and use of intraoral scanning systems to obtain single and multiple implant-supported fixed prostheses. However, no differences were identified between conventional flow vs. digital flow regarding complications and/or failures of prostheses.
- 3 August 2023
- Published by Research, Society and Development in Research, Society and Development
- Vol. 12 (8)
Open AccessPróteses unitárias fixas implantossuportadas obtidas pelo escaneamento digital: Revisão sistemática
Intraoral scanning is a viable alternative to be used in implant dentistry. However, the use of this technique is more in evidence in recent years and there is a need for a survey of studies to establish an indication protocol for the correct use of scanners and digital molding. Therefore, this study aims to conduct a systematic review with meta-analysis (Cochrane model; PRISMA and PROSPERO: CRD42022313310), in order to analyze the primary studies that evaluated techniques used to obtain moldings in single and partial fixed cases in implant dentistry, using the intraoral scanning system (intervention) compared to the conventional molding system for implant-supported prostheses (comparison). The PubMed/Medline, Cochrane Collaboration, Web of Science and SciELO databases were analyzed using area keywords. The collected data were tabulated and organized qualitatively. Clinical trials were classified according to hierarchy scales. The main results indicated the feasibility of digital scanning when compared to the conventional molding technique for making implant-supported prostheses. In addition, digital flow was associated with shorter clinical procedure time, when compared to conventional molding, greater satisfaction of patients. It is concluded that there is feasibility in the indication and use of intraoral scanning systems to obtain single and multiple implant-supported fixed prostheses. However, no differences were identified between conventional flow vs. digital flow regarding complications and/or failures of prostheses.