Sylvia H. Heywang-Köbrunner
Sylvia H. Heywang-Köbrunner has a total of 115 co-authors. Here are the top co-authors by number of shared publications:
Astrid Hacker
National Reference Center for Mammography Munich, Muenchen, Germany
7 shared publicationsAlexander Jänsch
FFB gGmbH Gesellschaft für Forschung und Fortbildung in der Brustdiagnose, Muenchen, Germany
5 shared publications- Ingrid Schreer
Radiologische Allianz Hamburg, Schäferkampsallee 5 - 7, 220357, Hamburg, Germany.
4 shared publications - Alexander Katalinic
Institute of Social Medicine and Epidemiology, University of Luebeck, Luebeck, Germany
3 shared publications Sina Weinand
LinkCare GmbH, Stuttgart, Germany
3 shared publicationsA. Hacker
Munich Reference Centre, Munich
2 shared publications
Latest Publications
- Open Access
Supplemental Breast Ultrasound in Mammography Screening for Women with Critically Dense Breasts
Background: The sensitivity of mammography screening is compromised in women with dense breast tissue. Supplemental ultrasound (S-US) can enhance cancer detection, but evidence regarding its feasibility, harms, and benefits within Western population-based screening programs remains limited. Methods: This pragmatic, prospective controlled trial was integrated into the German national mammography screening program across 16 sites. Breast density was assessed using automated AI software. Women with “critically dense” breasts (top 15–20%) were offered handheld supplemental S-US in addition to mammography (MXUS). The control group (MX-only) comprised women with comparable densities who did not receive S-US. Primary outcomes included cancer detection rate (CDR), recall rate, biopsy rate, and short-term follow-up recommendations. Results: From May 2020 to March 2024, 25,341 women underwent MXUS, while 38,529 received MX-only. The CDR was significantly higher in the MXUS group, at 10.7 per 1000 (95% CI: 9.4–12.0) compared to 7.2 per 1000 (95% CI: 6.4–8.1) in the MX-only group, yielding an incremental CDR of 3.5 per 1000 (95% CI: 1.9–5.0). However, MXUS led to higher rates of recall (6.6% vs. 5.4%), biopsies (3.2% vs. 1.5%), and short-term follow-up recommendations (0.9% vs. 0.5%). Conclusions: Implementing quality-assured S-US for women with critically dense breasts substantially increases the detection of invasive cancers, but also raises false positives. While these results support density-adapted screening, the high resource intensity suggests that future strategies should optimize risk stratification to target S-US more selectively. Long-term data are required to confirm clinical benefits.
Open AccessSupplemental Breast Ultrasound in Mammography Screening for Women with Critically Dense Breasts
Background: The sensitivity of mammography screening is compromised in women with dense breast tissue. Supplemental ultrasound (S-US) can enhance cancer detection, but evidence regarding its feasibility, harms, and benefits within Western population-based screening programs remains limited. Methods: This pragmatic, prospective controlled trial was integrated into the German national mammography screening program across 16 sites. Breast density was assessed using automated AI software. Women with “critically dense” breasts (top 15–20%) were offered handheld supplemental S-US in addition to mammography (MXUS). The control group (MX-only) comprised women with comparable densities who did not receive S-US. Primary outcomes included cancer detection rate (CDR), recall rate, biopsy rate, and short-term follow-up recommendations. Results: From May 2020 to March 2024, 25,341 women underwent MXUS, while 38,529 received MX-only. The CDR was significantly higher in the MXUS group, at 10.7 per 1000 (95% CI: 9.4–12.0) compared to 7.2 per 1000 (95% CI: 6.4–8.1) in the MX-only group, yielding an incremental CDR of 3.5 per 1000 (95% CI: 1.9–5.0). However, MXUS led to higher rates of recall (6.6% vs. 5.4%), biopsies (3.2% vs. 1.5%), and short-term follow-up recommendations (0.9% vs. 0.5%). Conclusions: Implementing quality-assured S-US for women with critically dense breasts substantially increases the detection of invasive cancers, but also raises false positives. While these results support density-adapted screening, the high resource intensity suggests that future strategies should optimize risk stratification to target S-US more selectively. Long-term data are required to confirm clinical benefits.
- 29 August 2023
- Published by SAGE Publications in Acta Radiologica
- Vol. 64 (10) , 2697-2703
Use of novel artificial intelligence computer-assisted detection (AI-CAD) for screening mammography: an analysis of 17,884 consecutive two-view full-field digital mammography screening exams
Background: Novel artificial intelligence computer-assisted detection (AI-CAD) systems based on deep learning (DL) promise to support screen reading. Purpose: To test a DL-AI-CAD system compared to human reading on consecutive screening mammograms. Material and Methods: In this retrospective study, 17,884 consecutive anonymized screening mammograms, double-read from January to November 2018, were processed by the DL-AI-CAD system. AI-CAD reading was considered positive if the AI-CAD case scores exceeded 30 (range = 1–100) and the lesion was correctly marked. Likewise, human reading (R1 or R2, respectively) was considered positive if the lesion was correctly identified and called. Receiver operating characteristic (ROC) analysis was performed and accuracy data were calculated. Ground truth for benign lesions: absence of malignancy after cancer registry matching (2022); for malignancy: histopathologic proof; evaluation was patient-based. Results: In total, 114 screen-detected and 17 interval cancers (ICA) occurred. ROC analysis of screen-detected cancers yielded an AUC of 89% for AI-CAD. Sensitivity/specificity was 81.7%/80.2% for AI-CAD; 77.1%/91.7% for R1; 78.6/91.6% for R2. Combining each human reading with AI-CAD was as sensitive as human double-reading (all approximately 88%), but less specific (approximately 75%) compared to human double-reading (approximately 87%). These AI-CAD combinations required consensus readings for twice as many cases as the human combination. Four of 17 ICA exceeded a case score of 30; two of four CAD correctly marked the quadrant of the subsequent ICA. Conclusion: Including ICA cases, this AI-CAD achieved comparable sensitivity to human reading at lower specificity. Combining human reading and AI-CAD allows increasing sensitivity compared to single-reading.
- 29 August 2023
- Published by SAGE Publications in Acta Radiologica
- Vol. 64 (10) , 2697-2703
Use of novel artificial intelligence computer-assisted detection (AI-CAD) for screening mammography: an analysis of 17,884 consecutive two-view full-field digital mammography screening exams
Background: Novel artificial intelligence computer-assisted detection (AI-CAD) systems based on deep learning (DL) promise to support screen reading. Purpose: To test a DL-AI-CAD system compared to human reading on consecutive screening mammograms. Material and Methods: In this retrospective study, 17,884 consecutive anonymized screening mammograms, double-read from January to November 2018, were processed by the DL-AI-CAD system. AI-CAD reading was considered positive if the AI-CAD case scores exceeded 30 (range = 1–100) and the lesion was correctly marked. Likewise, human reading (R1 or R2, respectively) was considered positive if the lesion was correctly identified and called. Receiver operating characteristic (ROC) analysis was performed and accuracy data were calculated. Ground truth for benign lesions: absence of malignancy after cancer registry matching (2022); for malignancy: histopathologic proof; evaluation was patient-based. Results: In total, 114 screen-detected and 17 interval cancers (ICA) occurred. ROC analysis of screen-detected cancers yielded an AUC of 89% for AI-CAD. Sensitivity/specificity was 81.7%/80.2% for AI-CAD; 77.1%/91.7% for R1; 78.6/91.6% for R2. Combining each human reading with AI-CAD was as sensitive as human double-reading (all approximately 88%), but less specific (approximately 75%) compared to human double-reading (approximately 87%). These AI-CAD combinations required consensus readings for twice as many cases as the human combination. Four of 17 ICA exceeded a case score of 30; two of four CAD correctly marked the quadrant of the subsequent ICA. Conclusion: Including ICA cases, this AI-CAD achieved comparable sensitivity to human reading at lower specificity. Combining human reading and AI-CAD allows increasing sensitivity compared to single-reading.
- Open Access
- 25 October 2021
- Published by Springer Nature in European Radiology
- Vol. 32 (4) , 2301-2312
Digital breast tomosynthesis (DBT) plus synthesised two-dimensional mammography (s2D) in breast cancer screening is associated with higher cancer detection and lower recalls compared to digital mammography (DM) alone: results of a systematic review and meta-analysis
Objectives: Digital breast tomosynthesis (DBT) plus digital mammography (DM) in screening is problematic due to increased radiation by the double exposure. Synthesised two-dimensional mammography (s2D) calculated from DBT datasets at no additional dose appears a sensible alternative compared to adding DM. This systematic review and meta-analysis focuses on screening performance outcomes in women screened with DBT plus s2D compared to DM alone. Methods: PubMed was searched from January 1, 2010, to September 2, 2020. Studies comparing DBT plus s2D to DM alone in breast cancer screening were included. Pooled risk ratios (RR) were estimated for cancer detection rates (CDR), recall rates, interval cancer rates (ICR), biopsy rates, and positive predictive values for recalls (PPV-1), for biopsies recommended (PPV-2), and for biopsies performed (PPV-3). Sensitivity analyses were performed using the leave-one-out approach. Risk of bias (RoB) was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool. Results: Twelve papers covering 414,281 women were included from 766 records identified. CDR is increased ([RR, 95% CI] 1.35, 1.20–1.52), recall rates are decreased (0.79, 0.64–0.98), and PPV-1 is increased (1.69, 1.45–1.96) when using DBT plus s2D compared to DM alone. ICR and biopsy rates did not differ, but PPV-2 respectively PPV-3 increased with DBT plus s2D (1.57, 1.08–2.28 respectively 1.36, 1.17–1.58). Overall RoB of studies was assessed to be low. Conclusion: Results show improved diagnostic outcomes with DBT plus s2D compared to DM alone and underline the value of DBT in combination with s2D in breast cancer screening. Key Points: • DBT plus s2D is associated with higher CDR, lower recall rates, and a higher PPV-1 compared to DM alone in breast cancer screening. • No differences in biopsy rates were found between screening modalities, but PPV-2 and PPV-3 were higher in women screened with DBT plus s2D compared to DM alone. • We identified inconsistent results of ICR in two studies comparing DBT plus s2D to DM alone—resulting in no differences when pooling ICR in meta-analysis.
- 25 October 2021
- Published by Springer Nature in European Radiology
- Vol. 32 (4) , 2301-2312
Open AccessDigital breast tomosynthesis (DBT) plus synthesised two-dimensional mammography (s2D) in breast cancer screening is associated with higher cancer detection and lower recalls compared to digital mammography (DM) alone: results of a systematic review and meta-analysis
Objectives: Digital breast tomosynthesis (DBT) plus digital mammography (DM) in screening is problematic due to increased radiation by the double exposure. Synthesised two-dimensional mammography (s2D) calculated from DBT datasets at no additional dose appears a sensible alternative compared to adding DM. This systematic review and meta-analysis focuses on screening performance outcomes in women screened with DBT plus s2D compared to DM alone. Methods: PubMed was searched from January 1, 2010, to September 2, 2020. Studies comparing DBT plus s2D to DM alone in breast cancer screening were included. Pooled risk ratios (RR) were estimated for cancer detection rates (CDR), recall rates, interval cancer rates (ICR), biopsy rates, and positive predictive values for recalls (PPV-1), for biopsies recommended (PPV-2), and for biopsies performed (PPV-3). Sensitivity analyses were performed using the leave-one-out approach. Risk of bias (RoB) was assessed using the Quality Assessment of Diagnostic Accuracy Studies (QUADAS)-2 tool. Results: Twelve papers covering 414,281 women were included from 766 records identified. CDR is increased ([RR, 95% CI] 1.35, 1.20–1.52), recall rates are decreased (0.79, 0.64–0.98), and PPV-1 is increased (1.69, 1.45–1.96) when using DBT plus s2D compared to DM alone. ICR and biopsy rates did not differ, but PPV-2 respectively PPV-3 increased with DBT plus s2D (1.57, 1.08–2.28 respectively 1.36, 1.17–1.58). Overall RoB of studies was assessed to be low. Conclusion: Results show improved diagnostic outcomes with DBT plus s2D compared to DM alone and underline the value of DBT in combination with s2D in breast cancer screening. Key Points: • DBT plus s2D is associated with higher CDR, lower recall rates, and a higher PPV-1 compared to DM alone in breast cancer screening. • No differences in biopsy rates were found between screening modalities, but PPV-2 and PPV-3 were higher in women screened with DBT plus s2D compared to DM alone. • We identified inconsistent results of ICR in two studies comparing DBT plus s2D to DM alone—resulting in no differences when pooling ICR in meta-analysis.
- Open Access
- 12 April 2021
- Published by International Platform of Registered Systematic Review and Meta-analysis Protocols (INPLASY)
Protocol of a systematic review and meta-analysis comparing digital breast tomosynthesis (DBT) plus synthesized two-dimensional mammography (s2D) to digital mammography (DM) alone in breast cancer screening
INPLASY202140073 Protocol of a systematic review and meta-analysis comparing digital breast tomosynthesis (DBT) plus synthesized two-dimensional mammography (s2D) to digital mammography (DM) alone in breast cancer screening Keywords: Systematic Review; Meta-Analysis; Mammography; Breast Neoplasms; Early Detection of Cancer. Download PDF – 202140073
- 12 April 2021
- Published by International Platform of Registered Systematic Review and Meta-analysis Protocols (INPLASY)
Open AccessProtocol of a systematic review and meta-analysis comparing digital breast tomosynthesis (DBT) plus synthesized two-dimensional mammography (s2D) to digital mammography (DM) alone in breast cancer screening
INPLASY202140073 Protocol of a systematic review and meta-analysis comparing digital breast tomosynthesis (DBT) plus synthesized two-dimensional mammography (s2D) to digital mammography (DM) alone in breast cancer screening Keywords: Systematic Review; Meta-Analysis; Mammography; Breast Neoplasms; Early Detection of Cancer. Download PDF – 202140073
- 14 October 2020
- Published by Springer Nature
- p. 343-354
Breast MRI Screening for the Intermediate Risk: An Open Issue
- 14 October 2020
- Published by Springer Nature
- p. 343-354
Breast MRI Screening for the Intermediate Risk: An Open Issue
- Open Access
- 5 February 2020
- Published by Springer Nature in Insights into Imaging
- Vol. 11 (1) , 1-18
Image-guided breast biopsy and localisation: recommendations for information to women and referring physicians by the European Society of Breast Imaging
We summarise here the information to be provided to women and referring physicians about percutaneous breast biopsy and lesion localisation under imaging guidance. After explaining why a preoperative diagnosis with a percutaneous biopsy is preferred to surgical biopsy, we illustrate the criteria used by radiologists for choosing the most appropriate combination of device type for sampling and imaging technique for guidance. Then, we describe the commonly used devices, from fine-needle sampling to tissue biopsy with larger needles, namely core needle biopsy and vacuum-assisted biopsy, and how mammography, digital breast tomosynthesis, ultrasound, or magnetic resonance imaging work for targeting the lesion for sampling or localisation. The differences among the techniques available for localisation (carbon marking, metallic wire, radiotracer injection, radioactive seed, and magnetic seed localisation) are illustrated. Type and rate of possible complications are described and the issue of concomitant antiplatelet or anticoagulant therapy is also addressed. The importance of pathological-radiological correlation is highlighted: when evaluating the results of any needle sampling, the radiologist must check the concordance between the cytology/pathology report of the sample and the radiological appearance of the biopsied lesion. We recommend that special attention is paid to a proper and tactful approach when communicating to the woman the need for tissue sampling as well as the possibility of cancer diagnosis, repeat tissue sampling, and or even surgery when tissue sampling shows a lesion with uncertain malignant potential (also referred to as “high-risk” or B3 lesions). Finally, seven frequently asked questions are answered.
- 5 February 2020
- Published by Springer Nature in Insights into Imaging
- Vol. 11 (1) , 1-18
Open AccessImage-guided breast biopsy and localisation: recommendations for information to women and referring physicians by the European Society of Breast Imaging
We summarise here the information to be provided to women and referring physicians about percutaneous breast biopsy and lesion localisation under imaging guidance. After explaining why a preoperative diagnosis with a percutaneous biopsy is preferred to surgical biopsy, we illustrate the criteria used by radiologists for choosing the most appropriate combination of device type for sampling and imaging technique for guidance. Then, we describe the commonly used devices, from fine-needle sampling to tissue biopsy with larger needles, namely core needle biopsy and vacuum-assisted biopsy, and how mammography, digital breast tomosynthesis, ultrasound, or magnetic resonance imaging work for targeting the lesion for sampling or localisation. The differences among the techniques available for localisation (carbon marking, metallic wire, radiotracer injection, radioactive seed, and magnetic seed localisation) are illustrated. Type and rate of possible complications are described and the issue of concomitant antiplatelet or anticoagulant therapy is also addressed. The importance of pathological-radiological correlation is highlighted: when evaluating the results of any needle sampling, the radiologist must check the concordance between the cytology/pathology report of the sample and the radiological appearance of the biopsied lesion. We recommend that special attention is paid to a proper and tactful approach when communicating to the woman the need for tissue sampling as well as the possibility of cancer diagnosis, repeat tissue sampling, and or even surgery when tissue sampling shows a lesion with uncertain malignant potential (also referred to as “high-risk” or B3 lesions). Finally, seven frequently asked questions are answered.
- 21 December 2017
- Published by Springer Nature
- p. 165-174
Benefit and Risks of Screening for Breast Cancer
- 21 December 2017
- Published by Springer Nature
- p. 165-174
Benefit and Risks of Screening for Breast Cancer
- 20 September 2017
- Published by SAGE Publications in Acta Radiologica
- Vol. 59 (7) , 782-788
Use of single-view digital breast tomosynthesis (DBT) and ultrasound vs. additional views and ultrasound for the assessment of screen-detected abnormalities: German multi-reader study
Background: Data on the value of digital breast tomosynthesis (DBT) for further assessment of screen-detected lesions are still limited. Purpose: To compare screening mammography, single-view DBT and ultrasound-information (TS) vs. screening mammography, additional views and ultrasound-information (AV) for assessment of screen-detected abnormalities. Material and Methods: The use of wide-angle DBT for screen-detected, soft-tissue abnormalities requiring additional views was investigated: 241 cases (206 benign and 35 malignant lesions), verified by histology or two-year follow-up, were read by ten readers as TS and as AV sets, yielding 2410 diagnoses for each set. Readings were randomly sequenced. Results: The mean interval between readings was nine weeks (random sequence). Evaluation was breast-based. Overall, in terms of area under receiver operating characteristic (AUC; varying degree of suspicion cutoff), TS and AV readings showed similar performance: for TS, AUC was 0.889 (95% confidence interval [CI] = 0.871–0.907) and for AV, AUC was 0.903 (95% CI = 0.886–0.921). TS readings had slightly higher sensitivity than AV readings (96.9% vs. 95.4%) but lower specificity (50% vs. 58.1%) and more variations between reader performance; absolute false negatives (FN) were reduced in 8/16 readers, equal in 5/16, and increased in only 3/16. Conclusion: This study broadly confirms previous data showing equivalence of DBT to AV. However, bias against TS may have occurred since the region of interest was not indicated in the TS set as compared to its obvious identification on the AV set by the selected spot views. A key finding is that reader experience with DBT may be more important than so far reported.
- 20 September 2017
- Published by SAGE Publications in Acta Radiologica
- Vol. 59 (7) , 782-788
Use of single-view digital breast tomosynthesis (DBT) and ultrasound vs. additional views and ultrasound for the assessment of screen-detected abnormalities: German multi-reader study
Background: Data on the value of digital breast tomosynthesis (DBT) for further assessment of screen-detected lesions are still limited. Purpose: To compare screening mammography, single-view DBT and ultrasound-information (TS) vs. screening mammography, additional views and ultrasound-information (AV) for assessment of screen-detected abnormalities. Material and Methods: The use of wide-angle DBT for screen-detected, soft-tissue abnormalities requiring additional views was investigated: 241 cases (206 benign and 35 malignant lesions), verified by histology or two-year follow-up, were read by ten readers as TS and as AV sets, yielding 2410 diagnoses for each set. Readings were randomly sequenced. Results: The mean interval between readings was nine weeks (random sequence). Evaluation was breast-based. Overall, in terms of area under receiver operating characteristic (AUC; varying degree of suspicion cutoff), TS and AV readings showed similar performance: for TS, AUC was 0.889 (95% confidence interval [CI] = 0.871–0.907) and for AV, AUC was 0.903 (95% CI = 0.886–0.921). TS readings had slightly higher sensitivity than AV readings (96.9% vs. 95.4%) but lower specificity (50% vs. 58.1%) and more variations between reader performance; absolute false negatives (FN) were reduced in 8/16 readers, equal in 5/16, and increased in only 3/16. Conclusion: This study broadly confirms previous data showing equivalence of DBT to AV. However, bias against TS may have occurred since the region of interest was not indicated in the TS set as compared to its obvious identification on the AV set by the selected spot views. A key finding is that reader experience with DBT may be more important than so far reported.
- 19 December 2016
- Published by Georg Thieme Verlag KG in Radiopraxis
- Vol. 9 (04) , 186
Buchrezensionen
Fazit: Das Buch stellt ein umfassendes Werk dar und ist sowohl für Mediziner als auch für Studierende, sowie Radiologietechnologen/MTRA zu empfehlen.
- 19 December 2016
- Published by Georg Thieme Verlag KG in Radiopraxis
- Vol. 9 (04) , 186
Buchrezensionen
Fazit: Das Buch stellt ein umfassendes Werk dar und ist sowohl für Mediziner als auch für Studierende, sowie Radiologietechnologen/MTRA zu empfehlen.