Ningcheng Gao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ningcheng Gao has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Haibo Yu
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
3 shared publications - Hui Zhang
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Junle Yan
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Zikang Ke
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
2 shared publications - Hui Zhang
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
1 shared publication - Ling Ning
School of Civil Engineering, Architecture and Environment, Hubei University of Technology, Wuhan 430068, China
1 shared publication
Latest Publications
- Open Access
- 15 November 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (22) , 15988
Solar Energy Utilization Potential in Urban Residential Blocks: A Case Study of Wuhan, China
In dense, energy-demanding urban areas, the effective utilization of solar energy resources, encompassing building-integrated photovoltaic (BIPV) systems and solar water heating (SWH) systems inside buildings, holds paramount importance for addressing concerns related to carbon emission reduction and the balance of energy supply and demand. This study aimed to examine the interplay between urban residential blocks and their solar energy potential, with the objective of promoting environmentally sustainable development within urban residential areas. The primary focus of this study was the hot summer and cold winter zone of China, which serves as a representative case study. Methodologically, we employed Rhinoceros and Grasshopper (GH) software version GH6.0 tools to simulate the solar radiation potential within residential blocks and translated this information into the potential utilization of BIPV and SWH systems. Subsequently, our focus was directed towards identifying optimal locations for mounting BIPV modules and water heaters on roofs and building façades. The study results revealed the following: (1) The floor area ratio (FAR), building density (BD), average building height (ABH), and space layout (SL) exerted substantial influences on the solar potential of a residential block, with correlations of up to 75%, 71%, 78%, and 50%, respectively, concerning the overall solar potential of the entire plot. (2) It is essential to emphasize that, with regard to the BIPV installation potential, façades account for 80% of the overall residential block potential, whereas rooftops contribute only 20%. Both south- and west-facing façades exhibited a BIPV installation ratio of approximately 34%. (3) In the realm of solar water heating, the potential for installations on building façades accounted for 77% of the total living area of the residential blocks, 23% on the rooftops, and 35% on the south-facing façades. This study furnishes practical guidelines for harnessing the potential of BIPV and SWH systems within residential blocks, thereby contributing to the advancement of sustainable urban development practices.
- 15 November 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (22) , 15988
Open AccessSolar Energy Utilization Potential in Urban Residential Blocks: A Case Study of Wuhan, China
In dense, energy-demanding urban areas, the effective utilization of solar energy resources, encompassing building-integrated photovoltaic (BIPV) systems and solar water heating (SWH) systems inside buildings, holds paramount importance for addressing concerns related to carbon emission reduction and the balance of energy supply and demand. This study aimed to examine the interplay between urban residential blocks and their solar energy potential, with the objective of promoting environmentally sustainable development within urban residential areas. The primary focus of this study was the hot summer and cold winter zone of China, which serves as a representative case study. Methodologically, we employed Rhinoceros and Grasshopper (GH) software version GH6.0 tools to simulate the solar radiation potential within residential blocks and translated this information into the potential utilization of BIPV and SWH systems. Subsequently, our focus was directed towards identifying optimal locations for mounting BIPV modules and water heaters on roofs and building façades. The study results revealed the following: (1) The floor area ratio (FAR), building density (BD), average building height (ABH), and space layout (SL) exerted substantial influences on the solar potential of a residential block, with correlations of up to 75%, 71%, 78%, and 50%, respectively, concerning the overall solar potential of the entire plot. (2) It is essential to emphasize that, with regard to the BIPV installation potential, façades account for 80% of the overall residential block potential, whereas rooftops contribute only 20%. Both south- and west-facing façades exhibited a BIPV installation ratio of approximately 34%. (3) In the realm of solar water heating, the potential for installations on building façades accounted for 77% of the total living area of the residential blocks, 23% on the rooftops, and 35% on the south-facing façades. This study furnishes practical guidelines for harnessing the potential of BIPV and SWH systems within residential blocks, thereby contributing to the advancement of sustainable urban development practices.
- Open Access
- 7 November 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (22) , 15687
Research on Microclimate-Suitable Spatial Patterns of Waterfront Settlements in Summer: A Case Study of the Nan Lake Area in Wuhan, China
As China’s urbanization progresses, thermal environmental problems such as the overheating effect experienced by cities are becoming more and more obvious in the daily lives of residents. Urban waterfront spaces not only create pleasant landscape environments and regulate microclimates, but also help to maintain ecological diversity. However, the current high-density urban construction model has led to poor air mobility and weakened water regulation functions in cities. Therefore, the rationalization of the spatial form of settlements has become particularly important in recent times. In this study, the Nan Lake area of Wuhan City was taken as the research object, and it was simulated using ENVI-met (5.5.1) software. Further, the orthogonal experimental design method was combined with the extremum difference analysis method. This study focused on the effects of the layout form (LF), floor area ratio (FAR), green form (GF), and offshore distance (OD) on the temperature (T), relative humidity (RH), and thermal comfort in waterfront settlements in summer. This study found that (1) among the various factors, the effect of the GFs and LFs on the overall microclimate of the study region was the most significant, while the volume ratio had the least significant effect on each indicator. (2) The parallel layout form was found to have better ventilation effects compared to the other three layout forms, with its cooling and humidifying effects being superior. (3) Among the four types of greening combinations, the combination of “grass + shrubs” had the best cooling effect at the height of pedestrians, while trees were able to reduce the heat transfer of solar radiation to the ground due to the shading and evaporation effects provided by their canopies. (4) The cooling and humidifying effects provided by the water body of Nan Lake gradually diminished as the distance from its shore increased; therefore, waterfront settlements maintaining a reasonable proximity to their water bodies will help bring into play the microclimate adjustment effect of such bodies. This study provides a valuable reference for the construction and renewal of urban waterfront settlements in the hot summer and cold winter zones of China (HSCW).
- 7 November 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (22) , 15687
Open AccessResearch on Microclimate-Suitable Spatial Patterns of Waterfront Settlements in Summer: A Case Study of the Nan Lake Area in Wuhan, China
As China’s urbanization progresses, thermal environmental problems such as the overheating effect experienced by cities are becoming more and more obvious in the daily lives of residents. Urban waterfront spaces not only create pleasant landscape environments and regulate microclimates, but also help to maintain ecological diversity. However, the current high-density urban construction model has led to poor air mobility and weakened water regulation functions in cities. Therefore, the rationalization of the spatial form of settlements has become particularly important in recent times. In this study, the Nan Lake area of Wuhan City was taken as the research object, and it was simulated using ENVI-met (5.5.1) software. Further, the orthogonal experimental design method was combined with the extremum difference analysis method. This study focused on the effects of the layout form (LF), floor area ratio (FAR), green form (GF), and offshore distance (OD) on the temperature (T), relative humidity (RH), and thermal comfort in waterfront settlements in summer. This study found that (1) among the various factors, the effect of the GFs and LFs on the overall microclimate of the study region was the most significant, while the volume ratio had the least significant effect on each indicator. (2) The parallel layout form was found to have better ventilation effects compared to the other three layout forms, with its cooling and humidifying effects being superior. (3) Among the four types of greening combinations, the combination of “grass + shrubs” had the best cooling effect at the height of pedestrians, while trees were able to reduce the heat transfer of solar radiation to the ground due to the shading and evaporation effects provided by their canopies. (4) The cooling and humidifying effects provided by the water body of Nan Lake gradually diminished as the distance from its shore increased; therefore, waterfront settlements maintaining a reasonable proximity to their water bodies will help bring into play the microclimate adjustment effect of such bodies. This study provides a valuable reference for the construction and renewal of urban waterfront settlements in the hot summer and cold winter zones of China (HSCW).
- Open Access
- 3 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (17) , 13210
An Empirical Study of a Passive Exterior Window for an Office Building in the Context of Ultra-Low Energy
As the energy crisis continues to intensify and with increasing awareness of global climate change, the issue of high energy consumption and emissions in buildings is garnering more attention. Windows have significant research value and importance as pivotal components in the development of ultra-low-energy buildings. This study presents a proposal for a passive exterior window considering the climatic conditions prevalent in the hot summer and cold winter zone of China. Firstly, an experimental platform was established outside a standard office to conduct tests and analyze the indoor thermal environment for four different scenarios in the summer and winter by comparing a passive room (PR) and non-passive room (NPR), respectively. The human apparent temperature was calculated based on the collected thermal environment data and subsequently evaluated. Lastly, the indoor environmental temperature (IET), window surface temperature (WST), and apparent temperature (AT) data were subjected to non-linear fitting regression analysis using Origin software. The primary aim of this analysis was to examine the impact of the passive exterior window on the indoor thermal environment and establish the feasibility of implementing such a window in the hot summer and cold winter zone of China. The results showed that: (1) in the summer, the IET and WST in the PR exhibited reductions of 0.8 °C and 0.6 °C, respectively, under ventilated conditions compared to the NPR; (2) in the winter, the IET and WST of the PR remained lower compared to those of the NPR (however, the temperature differential between the IET and WST in the PR amounted to 6.8 °C and 7.7 °C, respectively, while the corresponding disparity in the NPR was 8.1 °C and 9.3 °C); and (3) regarding the AT, during summer ventilation, the PR exhibited a substantial reduction of up to 3.5 °C in comparison to the NPR. Moreover, in the context of winter, the time for indoor human thermal perception to reach a comfortable level was extended by 0.5 h. Future investigations will delve into the influence of passive exterior windows on building energy consumption, and this research can provide a practical reference for energy-efficient design and retrofitting of exterior windows in the region.
- 3 September 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (17) , 13210
Open AccessAn Empirical Study of a Passive Exterior Window for an Office Building in the Context of Ultra-Low Energy
As the energy crisis continues to intensify and with increasing awareness of global climate change, the issue of high energy consumption and emissions in buildings is garnering more attention. Windows have significant research value and importance as pivotal components in the development of ultra-low-energy buildings. This study presents a proposal for a passive exterior window considering the climatic conditions prevalent in the hot summer and cold winter zone of China. Firstly, an experimental platform was established outside a standard office to conduct tests and analyze the indoor thermal environment for four different scenarios in the summer and winter by comparing a passive room (PR) and non-passive room (NPR), respectively. The human apparent temperature was calculated based on the collected thermal environment data and subsequently evaluated. Lastly, the indoor environmental temperature (IET), window surface temperature (WST), and apparent temperature (AT) data were subjected to non-linear fitting regression analysis using Origin software. The primary aim of this analysis was to examine the impact of the passive exterior window on the indoor thermal environment and establish the feasibility of implementing such a window in the hot summer and cold winter zone of China. The results showed that: (1) in the summer, the IET and WST in the PR exhibited reductions of 0.8 °C and 0.6 °C, respectively, under ventilated conditions compared to the NPR; (2) in the winter, the IET and WST of the PR remained lower compared to those of the NPR (however, the temperature differential between the IET and WST in the PR amounted to 6.8 °C and 7.7 °C, respectively, while the corresponding disparity in the NPR was 8.1 °C and 9.3 °C); and (3) regarding the AT, during summer ventilation, the PR exhibited a substantial reduction of up to 3.5 °C in comparison to the NPR. Moreover, in the context of winter, the time for indoor human thermal perception to reach a comfortable level was extended by 0.5 h. Future investigations will delve into the influence of passive exterior windows on building energy consumption, and this research can provide a practical reference for energy-efficient design and retrofitting of exterior windows in the region.