Mahmoud Abdallah El Kot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mahmoud Abdallah El Kot has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Yasser Abd Elmaboud
Department of mathematics, Applied College at Khulis, University Of Jeddah, Jeddah, Saudi Arabia
5 shared publications - Azza M. Algatheem
Department of Mathematics, College of Science, University of Bisha, P. O. Box 551, Bisha, 61922, Saudi Arabia
1 shared publication - Essam M. Elsaid
Department of Mathematics, College of Science, University of Bisha, P.O. Box 551, Bisha 61922, Saudi Arabia
1 shared publication M. A.
1 shared publication- Mohamed Rabea Eid
Center for Scientific Research and Entrepreneurship Northern Border University Arar Saudi Arabia
1 shared publication - Wael Abbas
Basic and Applied Science Department, College of Engineering and Technology, Arab Academy for Science, Technology and Maritime Transport, Cairo, Egypt
1 shared publication
Latest Publications
- 5 January 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 151 (2) , 1393-1410
Entropy generation of unsteady pulsatile electroosmotic blood flow through porous diseased artery: a variable viscosity model and Debye–Hückel approximation
- 5 January 2026
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 151 (2) , 1393-1410
Entropy generation of unsteady pulsatile electroosmotic blood flow through porous diseased artery: a variable viscosity model and Debye–Hückel approximation
- 15 November 2025
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 40 (03)
Beyond shear-thinning hyperbolic tangent electromagnetic nanofluid flow-based blood in porous constricted channels: Electroosmotic and activation energy dynamics
Atherosclerosis is the buildup of lipid deposits in the innermost layer of the artery, called the intima. It is the main cause of coronary artery disease and many brain-related disorders. This study looks at the unsteady magneto-electroosmotic flow of a shear-thinning hyperbolic tangent nanofluid in a porous, restricted artery. It takes radiative heat transfer, nonlinear convection, and activation energy into account. Chemical processes, Joule heating, and the modified Arrhenius equation are all included in a mathematical model. After converting the non-uniform domain into a uniform one, we use Crank–Nicolson finite difference methods to solve the governing equations. Based on the findings, the flow improves by approximately 10% when the Grashof numbers increase from 0 to 2, and the activation energy significantly reduces solute concentration. Electroosmotic forces (EOF) also significantly enhance temperature and concentration patterns, and entropy production increases with concentration gradients and thermal radiation levels. These investigations improve our understanding of how nanofluids behave in magnetic and electroosmotic situations. They also show the impact of this behavior on industrial and biological uses.
- 15 November 2025
- Published by World Scientific Pub Co Pte Ltd in Modern Physics Letters B
- Vol. 40 (03)
Beyond shear-thinning hyperbolic tangent electromagnetic nanofluid flow-based blood in porous constricted channels: Electroosmotic and activation energy dynamics
Atherosclerosis is the buildup of lipid deposits in the innermost layer of the artery, called the intima. It is the main cause of coronary artery disease and many brain-related disorders. This study looks at the unsteady magneto-electroosmotic flow of a shear-thinning hyperbolic tangent nanofluid in a porous, restricted artery. It takes radiative heat transfer, nonlinear convection, and activation energy into account. Chemical processes, Joule heating, and the modified Arrhenius equation are all included in a mathematical model. After converting the non-uniform domain into a uniform one, we use Crank–Nicolson finite difference methods to solve the governing equations. Based on the findings, the flow improves by approximately 10% when the Grashof numbers increase from 0 to 2, and the activation energy significantly reduces solute concentration. Electroosmotic forces (EOF) also significantly enhance temperature and concentration patterns, and entropy production increases with concentration gradients and thermal radiation levels. These investigations improve our understanding of how nanofluids behave in magnetic and electroosmotic situations. They also show the impact of this behavior on industrial and biological uses.
- 27 September 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics B
- Vol. 39 (25)
Electroosmotic flow of Eyring–Powell fluid in stenotic arteries: Effects of variable permeability and an extended Arrhenius relation
This paper offers a preliminary investigation of the electroosmotic Eyring–Powell fluid (blood model) in a stenotic artery within a porous medium with variable permeability. The main goal is to study the flow of a non-Newtonian fluid (Eyring–Powell) occurring in a stenosed artery in a porous medium with permeability that varies with time and an extended Arrhenius relation. Governing equations in a situation of mild stenosis were obtained and were subsequently solved numerically by implementing a finite difference technique. The model adopts the extended Arrhenius relation to take into account the temperature-related transport properties. The results depict that the higher Brownian motion will generate a uniform distribution of the low-density lipoprotein, such that the concentration gradient is weak. Such mixing and dispersion may have the potential benefits of targeted drug delivery. The given study is significant because it helps to accumulate knowledge about the complex interaction of hemodynamic phenomena in arteries with diseases.
- 27 September 2025
- Published by World Scientific Pub Co Pte Ltd in International Journal of Modern Physics B
- Vol. 39 (25)
Electroosmotic flow of Eyring–Powell fluid in stenotic arteries: Effects of variable permeability and an extended Arrhenius relation
This paper offers a preliminary investigation of the electroosmotic Eyring–Powell fluid (blood model) in a stenotic artery within a porous medium with variable permeability. The main goal is to study the flow of a non-Newtonian fluid (Eyring–Powell) occurring in a stenosed artery in a porous medium with permeability that varies with time and an extended Arrhenius relation. Governing equations in a situation of mild stenosis were obtained and were subsequently solved numerically by implementing a finite difference technique. The model adopts the extended Arrhenius relation to take into account the temperature-related transport properties. The results depict that the higher Brownian motion will generate a uniform distribution of the low-density lipoprotein, such that the concentration gradient is weak. Such mixing and dispersion may have the potential benefits of targeted drug delivery. The given study is significant because it helps to accumulate knowledge about the complex interaction of hemodynamic phenomena in arteries with diseases.
- Open Access
- 30 January 2024
- Published by Wiley
Theoretical simulation of blood flow for non-Newtonian fluid through the diseased catheterized curved artery with heat and mass transfer
The current paper deals with studying the physical characteristics of blood flow through a curved catheterized diseased artery with heat and mass transfer. The constitutive equations for incompressible and steady non-Newtonian Jeffrey fluid have been modelled and solved using the corresponding boundary conditions under the mild stenosis approximation to obtain analytical solutions for axial velocity, temperature and concentration. It is observed that, by increasing the curvature parameter, the blood velocity, the arterial wall shear stress and the temperature increase while the resistance to blood flow and concentration decrease. Besides, the values of blood velocity, arterial wall shear stress, and temperature are higher for Jeffrey fluid than for Newtonian fluid, while the inverse effect is observed for the resistance to blood flow and concentration. Moreover, the trapping phenomenon depicts that the symmetry of the trapped bolus destroys due to the curvature of the artery.
- 30 January 2024
- Published by Wiley
Open AccessTheoretical simulation of blood flow for non-Newtonian fluid through the diseased catheterized curved artery with heat and mass transfer
The current paper deals with studying the physical characteristics of blood flow through a curved catheterized diseased artery with heat and mass transfer. The constitutive equations for incompressible and steady non-Newtonian Jeffrey fluid have been modelled and solved using the corresponding boundary conditions under the mild stenosis approximation to obtain analytical solutions for axial velocity, temperature and concentration. It is observed that, by increasing the curvature parameter, the blood velocity, the arterial wall shear stress and the temperature increase while the resistance to blood flow and concentration decrease. Besides, the values of blood velocity, arterial wall shear stress, and temperature are higher for Jeffrey fluid than for Newtonian fluid, while the inverse effect is observed for the resistance to blood flow and concentration. Moreover, the trapping phenomenon depicts that the symmetry of the trapped bolus destroys due to the curvature of the artery.
- 4 November 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (04)
COMPUTATIONAL STUDY OF UNSTEADY PULSATILE BLOOD FLOW THROUGH A POROUS MULTI-IRREGULAR VERTICAL STENOSED ARTERY: IMPACTS OF HOMOGENEOUS–HETEROGENEOUS REACTIONS
Homogeneous and heterogeneous reactions are significant because many chemically reactive systems, such as biochemical systems, involve both types of reactions. This paper sheds light on the effects of homogeneous–heterogeneous reactions on magnetohydrodynamic blood flow through the catheterized multi-irregular vertically stenosed artery in non-Darcy porous media. The governing partial differential equations are simplified using mild stenosis approximations and then transformed into the computational domain to simplify the numerical calculations. It has been noticed that the fluid velocity and the flow rate go to their maximum values after a short time, and they decrease with fluctuation in the case of pulsating, but in the case of nonpulsatile, the behavior is steady. Moreover, an increase in the homogeneous heat reaction parameter decelerates the blood velocity, the flow rate and elevates the fluid temperature. Furthermore, the concentration reaches the steady state faster in the absence of a homogeneous thermal reaction.
- 4 November 2023
- Published by World Scientific Pub Co Pte Ltd in Journal of Mechanics in Medicine and Biology
- Vol. 24 (04)
COMPUTATIONAL STUDY OF UNSTEADY PULSATILE BLOOD FLOW THROUGH A POROUS MULTI-IRREGULAR VERTICAL STENOSED ARTERY: IMPACTS OF HOMOGENEOUS–HETEROGENEOUS REACTIONS
Homogeneous and heterogeneous reactions are significant because many chemically reactive systems, such as biochemical systems, involve both types of reactions. This paper sheds light on the effects of homogeneous–heterogeneous reactions on magnetohydrodynamic blood flow through the catheterized multi-irregular vertically stenosed artery in non-Darcy porous media. The governing partial differential equations are simplified using mild stenosis approximations and then transformed into the computational domain to simplify the numerical calculations. It has been noticed that the fluid velocity and the flow rate go to their maximum values after a short time, and they decrease with fluctuation in the case of pulsating, but in the case of nonpulsatile, the behavior is steady. Moreover, an increase in the homogeneous heat reaction parameter decelerates the blood velocity, the flow rate and elevates the fluid temperature. Furthermore, the concentration reaches the steady state faster in the absence of a homogeneous thermal reaction.
- 14 September 2023
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (2) , 2483-2498
Numerical Simulation of Electroosmotic Sutterby Hybrid Nanofluid Flowing Through an Irregularly Mild Stenotic Artery with an Aneurysm
- 14 September 2023
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 49 (2) , 2483-2498
Numerical Simulation of Electroosmotic Sutterby Hybrid Nanofluid Flowing Through an Irregularly Mild Stenotic Artery with an Aneurysm
- 13 December 2022
- Published by International Information and Engineering Technology Association in Mathematical Modelling of Engineering Problems
- Vol. 9 (5) , 1359-1368
Analytical Procedure for the Flow of a Carreau-Yasuda Fluid Through the Diseased Tapered Inclined Artery Subject to Heat Transfer and Chemical Reactions
This paper demonstrates the implications of heat transfer and chemical reactions by considering the flow of a Carreau-Yasuda fluid through the diseased tapered inclined artery. The analysis has performed on the artery with mild stenosis. The analytical solution has been obtained using the perturbation method due to its low Weissenberg number to get the blood velocity, the wall shear stress distribution, the temperature, the concentration, the resistance impedance and the stream function. The critical results in this study have depicted that the blood velocity for dilatant fluid is higher than that in viscous and pseudoplastic fluids in the core region of the artery. The value of blood velocity through a Newtonian fluid is extraordinarily lower than that through a Carreau-Yasuda fluid at the core region of the artery. The magnitude of blood velocity across the vertical artery is higher than those in the inclined and horizontal arteries inside the core region of the artery. The wall shear stress distributions are higher in the case of stenosis (diseased artery) than in no stenosis (healthy artery). The temperature transmission for the Carreau fluid is higher than that for the Carreau-Yasuda fluid. The flow resistance progressively increases as the depth of the stenosis increases. The size of the trapping bolus gradually increases, shifting toward the right at the diverging tapering artery, and it gradually increases, moving toward the left at the converging tapering artery. Finally, the streamlines are noticeably more comprehensive along the vertical artery and are higher than those in the inclined and horizontal arteries.
- 13 December 2022
- Published by International Information and Engineering Technology Association in Mathematical Modelling of Engineering Problems
- Vol. 9 (5) , 1359-1368
Analytical Procedure for the Flow of a Carreau-Yasuda Fluid Through the Diseased Tapered Inclined Artery Subject to Heat Transfer and Chemical Reactions
This paper demonstrates the implications of heat transfer and chemical reactions by considering the flow of a Carreau-Yasuda fluid through the diseased tapered inclined artery. The analysis has performed on the artery with mild stenosis. The analytical solution has been obtained using the perturbation method due to its low Weissenberg number to get the blood velocity, the wall shear stress distribution, the temperature, the concentration, the resistance impedance and the stream function. The critical results in this study have depicted that the blood velocity for dilatant fluid is higher than that in viscous and pseudoplastic fluids in the core region of the artery. The value of blood velocity through a Newtonian fluid is extraordinarily lower than that through a Carreau-Yasuda fluid at the core region of the artery. The magnitude of blood velocity across the vertical artery is higher than those in the inclined and horizontal arteries inside the core region of the artery. The wall shear stress distributions are higher in the case of stenosis (diseased artery) than in no stenosis (healthy artery). The temperature transmission for the Carreau fluid is higher than that for the Carreau-Yasuda fluid. The flow resistance progressively increases as the depth of the stenosis increases. The size of the trapping bolus gradually increases, shifting toward the right at the diverging tapering artery, and it gradually increases, moving toward the left at the converging tapering artery. Finally, the streamlines are noticeably more comprehensive along the vertical artery and are higher than those in the inclined and horizontal arteries.
- 26 April 2021
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (6) , 4355-4368
Unsteady pulsatile fractional Maxwell viscoelastic blood flow with Cattaneo heat flux through a vertical stenosed artery with body acceleration
- 26 April 2021
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (6) , 4355-4368
Unsteady pulsatile fractional Maxwell viscoelastic blood flow with Cattaneo heat flux through a vertical stenosed artery with body acceleration
- 17 June 2016
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 20 (1) , 45-58
Numerical technique of blood flow through catheterized arteries with overlapping stenosis
This study is concerned with the surgical technique for the injection of a catheter through arteries with overlapping stenosis in the presence of externally applied magnetic field and Hall currents influences. The nature of blood is analyzed mathematically by considering it as a micropolar fluid. The analysis is carried out for an artery with a mild stenosis. The governing equations with the corresponding boundary conditions solved numerically using Crank–Nicolson implicit finite difference scheme. The numerical technique give excellent agreement for axial velocity of the fluid, the circumferential microrotation, the wall shear stress distribution and the contour plots of stream lines. The obtained results show that the value of axial velocity is higher for a Newtonian fluid than that for a micropolar fluid model, the effect of suitable moving magnetic field (Hall currents influences) accelerates the speed of blood, the size of trapped bolus for the stream lines decrease if the spinning movement of the fluid molecules have considerable value regardless of small or large size of the fluid molecules and the flow of fluid is better with increasing the Hall current effect and the size of trapping bolus increase clearly by increasing the maximum height of stenosis where the fluid moves as a bulk.
- 17 June 2016
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 20 (1) , 45-58
Numerical technique of blood flow through catheterized arteries with overlapping stenosis
This study is concerned with the surgical technique for the injection of a catheter through arteries with overlapping stenosis in the presence of externally applied magnetic field and Hall currents influences. The nature of blood is analyzed mathematically by considering it as a micropolar fluid. The analysis is carried out for an artery with a mild stenosis. The governing equations with the corresponding boundary conditions solved numerically using Crank–Nicolson implicit finite difference scheme. The numerical technique give excellent agreement for axial velocity of the fluid, the circumferential microrotation, the wall shear stress distribution and the contour plots of stream lines. The obtained results show that the value of axial velocity is higher for a Newtonian fluid than that for a micropolar fluid model, the effect of suitable moving magnetic field (Hall currents influences) accelerates the speed of blood, the size of trapped bolus for the stream lines decrease if the spinning movement of the fluid molecules have considerable value regardless of small or large size of the fluid molecules and the flow of fluid is better with increasing the Hall current effect and the size of trapping bolus increase clearly by increasing the maximum height of stenosis where the fluid moves as a bulk.