Deepak Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Deepak Kumar has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- G. Lloyds Raja
National Institute of Technology Patna
6 shared publications - Mohamed Alkhatib
United Arab Emirates University
3 shared publications - Utkal Ranjan Muduli
APEC, Dept. of Electrical Engineering and Computer Science, Khalifa University, Abu Dhabi, UAE
3 shared publications - Pulakraj Aryan
Department of Electrical Engineering, Manipal University Jaipur, Jaipur, Rajasthan, India
2 shared publications - Akash Kumar Deep
Department of Electrical Engineering, National Institute of Technology, Patna, India
1 shared publication - Dharmendra Kumar Dheer
National Institute of Technology Patna
1 shared publication
Latest Publications
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (6) , 9028-9045
Stability-Constrained Optimization of a FO(I+PID) Controller for Robust AGC Amid Variable Communication Latency and Hybrid Cyber Threats
The phase lag associated with conventional internal model control strategies for thermal power plants (TPP) with dead time (DT) affects its ability to restore frequency and tie-line power deviations. For the aforementioned reason and foreseen merits of fractional calculus, a robust uni-parametric fractional order integral and proportional integral derivative (FO(I+PID)) controller is proposed for a renewable integrated TPP amid DT. This FO(I+PID) controller is designed based on a frequency-shifted version of the TPP's fractional model, which eliminates the need for phase-lag inducing internal model control filters in conventional designs. The frequency-shifting factor ($\mu$) serves as the only tuning parameter that determines the performance and robustness of the FO(I+PID)-based load frequency control strategy, thereby offering the advantage of simplicity, which is desirable in practice. After applying Pade's approximation and stability considerations (to obtain the upper and lower bounds of $\mu$), its optimal value is obtained using the crayfish optimization algorithm. The efficacy of this scheme is demonstrated through simulations, hardware-in-loop validation, and the IEEE 39-bus system by considering various practical scenarios like step load changes, hybrid cyber attacks, variable communication delay, nonlinearities associated with the TPP, and rigorous sensitivity-based stability/fragility analysis by perturbing TPP model/controller parameters. It outperforms $Max\_{v}$ of tie-line power deflection by 70.57% and 72.44% compared to FIMC and TFC, respectively. Moreover, settling time is reduced to 103.2s, outperforming TFC (149.87s), FIMC (114.3s), and PI (131.87s). It confirms the better transient performance of the FO(I+PID) controller over reported techniques.
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 62 (6) , 9028-9045
Stability-Constrained Optimization of a FO(I+PID) Controller for Robust AGC Amid Variable Communication Latency and Hybrid Cyber Threats
The phase lag associated with conventional internal model control strategies for thermal power plants (TPP) with dead time (DT) affects its ability to restore frequency and tie-line power deviations. For the aforementioned reason and foreseen merits of fractional calculus, a robust uni-parametric fractional order integral and proportional integral derivative (FO(I+PID)) controller is proposed for a renewable integrated TPP amid DT. This FO(I+PID) controller is designed based on a frequency-shifted version of the TPP's fractional model, which eliminates the need for phase-lag inducing internal model control filters in conventional designs. The frequency-shifting factor ($\mu$) serves as the only tuning parameter that determines the performance and robustness of the FO(I+PID)-based load frequency control strategy, thereby offering the advantage of simplicity, which is desirable in practice. After applying Pade's approximation and stability considerations (to obtain the upper and lower bounds of $\mu$), its optimal value is obtained using the crayfish optimization algorithm. The efficacy of this scheme is demonstrated through simulations, hardware-in-loop validation, and the IEEE 39-bus system by considering various practical scenarios like step load changes, hybrid cyber attacks, variable communication delay, nonlinearities associated with the TPP, and rigorous sensitivity-based stability/fragility analysis by perturbing TPP model/controller parameters. It outperforms $Max\_{v}$ of tie-line power deflection by 70.57% and 72.44% compared to FIMC and TFC, respectively. Moreover, settling time is reduced to 103.2s, outperforming TFC (149.87s), FIMC (114.3s), and PI (131.87s). It confirms the better transient performance of the FO(I+PID) controller over reported techniques.
- 5 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-18
Delay-Compensated Double-Loop IDFD Controller for EV-Assisted Renewable-Integrated Thermal Power Systems Amid Cyber Threats
Modern automatic generation control (AGC) systems suffer from instability as well as delayed corrective actions in response to frequency and tie line power aberrations due to communication time delays (TD) and cyber threats. Additionally, the sporadic nature of the renewable energy sources (RES), electric vehicles (EVs) and energy storage systems further introduces complexities in AGC. Therefore, this work proposes a double-loop-based integral dual fractional derivative (IDFD) controller to enhance robustness and stability in EV-assisted dual-area thermal power systems (TPS) under such adverse conditions. The IDFD controller is developed via the internal model control theory grounded on the fractional-order model of the TPS. The performance-robustness tradeoff is improved through the judicious selection of the single tuning parameter ($\alpha$) based on gain and phase margin specifications with birds-of-prey-based optimisation by minimising integral time absolute error of area control error. The proposed controller is validated using both simulation and hardware-in-the-loop implementation to show its practical feasibility. Case studies are performed on dual-area TPS and a realistic IEEE 39- bus test system, demonstrating superior dynamic response and enhanced resilience against cyber threats, TD, parametric uncertainties, multiple-step load disturbance, and non-linearities.
- 5 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-18
Delay-Compensated Double-Loop IDFD Controller for EV-Assisted Renewable-Integrated Thermal Power Systems Amid Cyber Threats
Modern automatic generation control (AGC) systems suffer from instability as well as delayed corrective actions in response to frequency and tie line power aberrations due to communication time delays (TD) and cyber threats. Additionally, the sporadic nature of the renewable energy sources (RES), electric vehicles (EVs) and energy storage systems further introduces complexities in AGC. Therefore, this work proposes a double-loop-based integral dual fractional derivative (IDFD) controller to enhance robustness and stability in EV-assisted dual-area thermal power systems (TPS) under such adverse conditions. The IDFD controller is developed via the internal model control theory grounded on the fractional-order model of the TPS. The performance-robustness tradeoff is improved through the judicious selection of the single tuning parameter ($\alpha$) based on gain and phase margin specifications with birds-of-prey-based optimisation by minimising integral time absolute error of area control error. The proposed controller is validated using both simulation and hardware-in-the-loop implementation to show its practical feasibility. Case studies are performed on dual-area TPS and a realistic IEEE 39- bus test system, demonstrating superior dynamic response and enhanced resilience against cyber threats, TD, parametric uncertainties, multiple-step load disturbance, and non-linearities.
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-14
Robust and Unified Fractional Order AGC-AVR Scheme for Hydropower Plant
Hydropower plants are well known for their nonlinear and non-minimum phase behavior, which poses significant challenges in automatic generation control (AGC) and automatic voltage regulation (AVR). Although integrated AGC-AVR methods are common for thermal power plants, there's still a need for robust, unified solutions tailored to hydropower systems. This paper proposes a simple and unified fractional-order frequency-shifted PID controller with a fractional filter (FS-FPIDF) to address this gap. A fractional-order model of a non-reheated hydropower plant is derived and then frequency-shifted to design the FS-FPIDF controller, featuring a single tuning parameter optimized via integral square error (ISE) minimization of voltage and frequency deviations. The proposed control scheme demonstrates robustness against sudden load changes, nonlinearities, model uncertainties, and stealthy cyber-threats, including false data injection (FDI) and denial of service (DoS). Additionally, the methodology is scalable and has been evaluated on a renewable-integrated IEEE 39-bus hydro-thermal system to assess its performance in maintaining frequency and voltage stability amidst the stochastic nature of renewable energy sources. Practical feasibility of this proposal is ascertained using OPAL-RT-based hardware-in-loop validation. Compared to conventional integer-order control methods, the proposed FS-FPIDF controller ensures superior regulation without increasing design complexity.
- 18 March 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. PP (00939994) , 1-14
Robust and Unified Fractional Order AGC-AVR Scheme for Hydropower Plant
Hydropower plants are well known for their nonlinear and non-minimum phase behavior, which poses significant challenges in automatic generation control (AGC) and automatic voltage regulation (AVR). Although integrated AGC-AVR methods are common for thermal power plants, there's still a need for robust, unified solutions tailored to hydropower systems. This paper proposes a simple and unified fractional-order frequency-shifted PID controller with a fractional filter (FS-FPIDF) to address this gap. A fractional-order model of a non-reheated hydropower plant is derived and then frequency-shifted to design the FS-FPIDF controller, featuring a single tuning parameter optimized via integral square error (ISE) minimization of voltage and frequency deviations. The proposed control scheme demonstrates robustness against sudden load changes, nonlinearities, model uncertainties, and stealthy cyber-threats, including false data injection (FDI) and denial of service (DoS). Additionally, the methodology is scalable and has been evaluated on a renewable-integrated IEEE 39-bus hydro-thermal system to assess its performance in maintaining frequency and voltage stability amidst the stochastic nature of renewable energy sources. Practical feasibility of this proposal is ascertained using OPAL-RT-based hardware-in-loop validation. Compared to conventional integer-order control methods, the proposed FS-FPIDF controller ensures superior regulation without increasing design complexity.
- Top Cited PapersOpen Access
- 7 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 4515-4529
Smith Predictor Based Fractional LFC Strategy for Storage Supported Thermal Power System Amid Communication Dead Time and Cyber Threats
Communication dead time (CDT) amid integration of renewable energy sources (RESs) and energy storage systems (ESSs) into modern power system networks can result in instabilities, phase lags and sluggish corrective action when dealing with frequency and tie-line power deviations. To compensate CDT, a Smith predictor based Fractional Order Proportional-Integral-Derivative with Integrator (FPIDI) controller is analytically designed for a dual-area thermal power system (TPS) with integrated RES, battery ESS, flywheel ESS and Ultra-capacitors. The FPIDI controller is designed using a modified internal model control (IMC) theory that is based on the frequency-relocated fractional-order model of the TPS. This modified IMC method eliminates the need of phase-lag inducing IMC filter. The performance-robustness tradeoff is enhanced by appropriate selection of the single tuning parameter (frequency-relocation factor ($\psi$)) by minimizing the integral of time-weighted absolute value of area control errors. The proposed controller is validated both by simulation and hardware-in-loop implementation to show its practical feasibility.
- 7 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (3) , 4515-4529
Top Cited PapersOpen AccessSmith Predictor Based Fractional LFC Strategy for Storage Supported Thermal Power System Amid Communication Dead Time and Cyber Threats
Communication dead time (CDT) amid integration of renewable energy sources (RESs) and energy storage systems (ESSs) into modern power system networks can result in instabilities, phase lags and sluggish corrective action when dealing with frequency and tie-line power deviations. To compensate CDT, a Smith predictor based Fractional Order Proportional-Integral-Derivative with Integrator (FPIDI) controller is analytically designed for a dual-area thermal power system (TPS) with integrated RES, battery ESS, flywheel ESS and Ultra-capacitors. The FPIDI controller is designed using a modified internal model control (IMC) theory that is based on the frequency-relocated fractional-order model of the TPS. This modified IMC method eliminates the need of phase-lag inducing IMC filter. The performance-robustness tradeoff is enhanced by appropriate selection of the single tuning parameter (frequency-relocation factor ($\psi$)) by minimizing the integral of time-weighted absolute value of area control errors. The proposed controller is validated both by simulation and hardware-in-loop implementation to show its practical feasibility.
- 30 November 2023
- Published by Taylor & Francis in International Journal of Systems Science
- Vol. 55 (3) , 499-516
Relocated internal model control based cascade control strategy for stable and unstable systems with delay
- 30 November 2023
- Published by Taylor & Francis in International Journal of Systems Science
- Vol. 55 (3) , 499-516
Relocated internal model control based cascade control strategy for stable and unstable systems with delay
- 3 September 2023
- Published by Elsevier in Chemical Engineering Science
- Vol. 282
Generalized optimal 3-degree of freedom parallel cascade control strategy for stable, unstable and integrating chemical processes
- 3 September 2023
- Published by Elsevier in Chemical Engineering Science
- Vol. 282
Generalized optimal 3-degree of freedom parallel cascade control strategy for stable, unstable and integrating chemical processes