THTianqi Hu

Tianqi Hu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Tianqi Hu has a total of 289 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Towards non-invasive sediment monitoring using muography: A pilot run at the Shanghai Outer Ring Tunnel

    by Kim Siang Khaw, Siew Yan Hoh, Tianqi Hu, Xingyun Huang, Jun Kai Ng, Yusuke Takeuchi, Min Yang Tan, Jiangtao Wang, Yinghe Wang, Guan Ming Wong, et al.

    This study demonstrates the application of cosmic-ray muography as a non-invasive method for monitoring sediment accumulation and tidal influences in the Shanghai Outer Ring Tunnel, an immersed tube tunnel located beneath the Huangpu River in Shanghai, China. A portable, dual-layer plastic scintillator detector was deployed to conduct muon flux scans along the tunnel’s length and to continuously monitor muon flux, allowing for the study of tidal effects. Geant4 simulations validated the correlation between muon attenuation and overburden thickness, incorporating sediment, water, and concrete layers. Key findings include a strong anti-correlation between the measured muon flux and the water levels observed at a nearby tide gauge. The results align with geotechnical data and simulations, especially in the region of interest, confirming muography’s sensitivity to sediment dynamics. This work establishes muography as a robust tool for long-term, real-time monitoring of submerged infrastructure, offering significant advantages over conventional invasive techniques. The study underscores the potential for integrating muography into civil engineering practices to enhance safety and operational resilience in tidal environments.


  • Top Cited Papers
    Open Access

    Measurement of the positive muon anomalous magnetic moment to 127 ppb

    by D. P. Aguillard, T. Albahri, D. Allspach, J. Annala, K. Badgley, S. Baeßler, I. Bailey, L. Bailey, E. Barlas-Yucel, T. Barrett, et al.

    A new measurement of the magnetic anomaly a μ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon g − 2 Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine a μ = 1 165 920 710 ( 162 ) × 10 − 12 (139 ppb) for the new datasets, and a μ = 1 165 920 705 ( 148 ) × 10 − 12 (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is a μ ( exp ) = 1 165 920 715 ( 145 ) × 10 − 12 (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of 4.


  • Development of Fast Front-End Electronics for the Muon Trigger Detector in the PSI muEDM Experiment

    by Tianqi Hu, Guan Ming Wong, Chavdar Dutsov, Siew Yan Hoh, Kim Siang Khaw, Diego Alejandro Sanz Becerra, Philipp Schmidt-Wellenburg, Yuzhi Shang, Yusuke Takeuchi

    This paper outlines the design and development of a fast front-end electronic readout board for the muon trigger detector in the muEDM experiment at the Paul Scherrer Institute. The trigger detector, which consists of a gate and aperture detector, is strategically located at the end of the superconducting injection channel to generate trigger signals for a magnetic kicker, which activates upon the injection of muons into the central region of the storage solenoid. Within the magnetic field of the solenoid, the system configuration is optimized to meet stringent performance specifications, including minimal signal propagation delays, high detection efficiency, non-magnetic properties, and consistent operational stability under varying experimental conditions. Additionally, the design incorporates robust methods for rejecting positron contamination in the muon beamline. The results presented include performance evaluations from both bench testing and actual beam tests, highlighting the effectiveness and reliability of the electronic design.


  • Open Access

    A compact frozen-spin trap for the search for the electric dipole moment of the muon

    by A. Adelmann, A. R. Bainbridge, I. Bailey, A. Baldini, S. Basnet, N. Berger, L. Bianco, C. Calzolaio, L. Caminada, G. Cavoto, et al.

    Electric dipole moments (EDM) of fundamental particles inherently violate time-reversal (T) and the combined charge-conjugation and parity symmetry (CP). We aim to measure the EDM of the muon using the frozen-spin technique within a compact storage trap. This method exploits the high effective electric field, $$E\approx {165\,\mathrm{MV/m}}$$ E ≈ 165 MV / m , experienced in the rest frame of the muon with a momentum of about $${23\,\mathrm{MeV/}}c$$ 23 MeV / c when it passes through a solenoidal magnetic field of $$|\vec {B}|={2.5\,\textrm{T}}$$ | B → | = 2.5 T . In this paper, we outline the fundamental considerations for a muon EDM search and present a conceptual design for a demonstration experiment to be conducted at secondary muon beamlines of the Paul Scherrer Institute in Switzerland. In Phase I, with an anticipated data acquisition period of 200 days, the expected sensitivity to a muon EDM is $$\sigma (d)\le {4E-21\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ σ ( d ) ≤ 4 E - 21 e · cm . In a subsequent phase, Phase II, we propose to improve the sensitivity to $$\sigma (d)\le {6E-23\,\mathrm{{\text {e}}\!\cdot \!\text {cm}}}$$ σ ( d ) ≤ 6 E - 23 e · cm using a dedicated instrument installed on a different beamline that produces muons of momentum 125 $$\textrm{MeV}\!/\!{ c}$$ MeV / c .


  • Beam test performance of a prototype muon trigger detector for the PSI muEDM experiment

    by Tianqi Hu, Jun Kai Ng, Guan Ming Wong, Cheng Chen, Kim Siang Khaw, Meng Lyu, Angela Papa, Philipp Schmidt-Wellenburg, David Staeger, Bastiano Vitali


  • Top Cited Papers
    Open Access

    Detailed report on the measurement of the positive muon anomalous magnetic moment to 0.20 ppm

    by D. P. Aguillard, T. Albahri, D. Allspach, A. Anisenkov, K. Badgley, S. Baeßler, I. Bailey, L. Bailey, V. A. Baranov, E. Barlas-Yucel, et al.

    We present details on a new measurement of the muon magnetic anomaly, aμ=(gμ−2)/2. The result is based on positive muon data taken at Fermilab’s Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses 3.1  GeV/c polarized muons stored in a 7.1-m-radius storage ring with a 1.45 T uniform magnetic field. The value of aμ is determined from the measured difference between the muon spin precession frequency and its cyclotron frequency. This difference is normalized to the strength of the magnetic field, measured using nuclear magnetic resonance. The ratio is then corrected for small contributions from beam motion, beam dispersion, and transient magnetic fields. We measure aμ=116592057(25)×10−11 (0.21 ppm). This is the world’s most precise measurement of this quantity and represents a factor of 2.2 improvement over our previous result based on the 2018 dataset. In combination, the two datasets yield aμ(FNAL)=116592055(24)×10−11 (0.20 ppm). Combining this with the measurements from Brookhaven National Laboratory for both positive and negative muons, the new world average is aμ(exp)=116592059(22)×10−11 (0.19 ppm).


  • Top Cited Papers
    Open Access

    Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

    by D. P. Aguillard, T. Albahri, D. Allspach, A. Anisenkov, K. Badgley, S. Baeßler, I. Bailey, L. Bailey, V. A. Baranov, E. Barlas-Yucel, et al.

    We present a new measurement of the positive muon magnetic anomaly, aμ≡(gμ−2)/2, from the Fermilab Muon g−2 Experiment using data collected in 2019 and 2020. We have analyzed more than 4 times the number of positrons from muon decay than in our previous result from 2018 data. The systematic error is reduced by more than a factor of 2 due to better running conditions, a more stable beam, and improved knowledge of the magnetic field weighted by the muon distribution, ω˜p′, and of the anomalous precession frequency corrected for beam dynamics effects, ωa. From the ratio ωa/ω˜p′, together with precisely determined external parameters, we determine aμ=116 592 057(25)×10−11 (0.21 ppm). Combining this result with our previous result from the 2018 data, we obtain aμ(FNAL)=116 592 055(24)×10−11 (0.20 ppm). The new experimental world average is aμ(exp)=116 592 059(22)×10−11 (0.19 ppm), which represents a factor of 2 improvement in precision.


  • Open Access

    Status of the muEDM Experiment at PSI

    by Kim Siang Khaw, Cheng Chen, Massimo Giovannozzi, Tianqi Hu, Meng Lv, Jun Kai Ng, Angela Papa, Philipp Schmidt-Wellenburg, Bastiano Vitali, Guan Ming Wong

    Permanent electric dipole moments (EDMs) are excellent probes of physics beyond the Standard Model, especially on new sources of CP violation. The muon EDM has recently attracted significant attention due to discrepancies in the magnetic anomaly of the muon, as well as potential violations of lepton-flavor universality in B-meson decays. At the Paul Scherrer Institute in Switzerland, we have proposed a muon EDM search experiment employing the frozen-spin technique, where a radial electric field is exerted within a storage solenoid to cancel the muon’s anomalous spin precession. Consequently, the EDM signal can be inferred from the upstream-downstream asymmetry of the decay positron count versus time. The experiment is planned to take place in two phases, anticipating an annual statistical sensitivity of 3×10−21e·cm for Phase I and 6×10−23e·cm for Phase II. Going beyond 10−21e·cm will enable us to probe various Standard Model extensions.