DFDaihua Fu

Daihua Fu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Daihua Fu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Spatiotemporally Orchestrated H 2 S/NO‐Releasing Stent for Synergistic Vascular Healing

    by Jiayi Zhang, Yang Li, Zhen Xiang, Daihua Fu, Yunbing Wang

    Cardiovascular stents persistently struggle to reconcile rapid endothelialization with long‐term prevention of thrombosis and restenosis. This study develops a spatiotemporally orchestrated dual‐gas‐releasing hydrogel coating that synchronizes H 2 S and NO delivery with the dynamic phases of vascular healing. The coating is fabricated by covalently grafting an alginate coating onto poly(L‐lactic acid) stents via a benzophenone‐mediated two‐step surface photopolymerization. A thiol‑activated H 2 S donor is anchored within the coating, while alginate‑chelated Cu 2 ⁺ catalyzes NO generation from endogenous S‑nitrosothiols. An early H 2 S burst synergizes with NO to suppress thromboinflammation and prime a regenerative niche, while sustained NO release maintains vascular homeostasis and directs long‐term remodeling. The coating reduces platelet adhesion by over 90%, virtually eliminates thrombosis in an arteriovenous shunt model, triples endothelial coverage, and suppresses smooth muscle cell proliferation by ≈73%. It also reprograms macrophage polarization, increasing the M2/M1 ratio tenfold, and reduces intracellular ROS levels by >90%. In a rabbit abdominal aorta model, the coating promotes flow‐aligned endothelialization, achieving CD31⁺/eNOS⁺ coverage comparable to native tissue within 3 months, while decreasing neointimal thickness by 66% versus controls. This spatiotemporally tailored gasotransmitter delivery resolves the healing dichotomy of stents, providing a clinically translatable platform for next‐generation vascular implants.


  • Dual-mode nitric oxide releasing vascular grafts for vascular homeostasis and antibacterial defense

    by Yang Li, Jiayi Zhang, Zhen Xiang, Julin Wang, Siyu Ren, Jichun Zhao, Daihua Fu, Yunbing Wang


  • In Situ H2S-Releasing Stents Optimize Vascular Healing

    by Jiayi Zhang, Yang Li, Zhen Xiang, Hongxia Pu, Cheng Ji, Xingrong Ren, Daihua Fu, Yunbing Wang

    Stent implantation remains a cornerstone of interventional cardiology, providing a minimally invasive solution to restore blood flow in occluded vessels. However, current stents face persistent challenges in simultaneously preventing neointimal hyperplasia and promoting reendothelialization, compromising their long-term efficacy. To address these limitations, we developed an in situ H2S-releasing polymer brush-coated stent that actively modulates material-blood interactions, creating a favorable microenvironment for vascular healing. H2S enhances the stent's antithrombotic properties by inhibiting fibrinogen binding and platelet activation, while also mitigating oxidative stress and promoting macrophage polarization toward the anti-inflammatory M2 phenotype. In vivo, the H2S-releasing stents significantly improved vascular healing by accelerating endothelialization and inhibiting smooth muscle cell overproliferation, resulting in a thinner neointima with functional endothelial coverage. Transcriptomic analysis further elucidated the underlying mechanisms, revealing H2S-mediated modulation of key biological pathways that support vascular healing. These findings underscore the potential of in situ H2S release as an effective strategy for optimizing vascular implants and improving long-term outcomes.


  • Hierarchical Biomimetic Electrospun Vascular Grafts for Improved Patency and Regeneration

    by Zhen Xiang, Yuwei Xiang, Yang Li, Jiayi Zhang, Chen Zhou, Hui Yan, Daihua Fu, Yunbing Wang

    Small‐diameter vascular grafts (SDVGs) are essential for cardiovascular disease treatment, particularly in arterial replacement and bypass surgeries. Despite their importance, SDVGs often fail due to thrombosis, inflammation, and intimal hyperplasia, limiting their clinical application. This study develops a hierarchical biomimetic SDVG with a bilayered structure, comprising a dense inner layer and a loose outer layer with larger pores, integrated with a multifunctional coating containing polydopamine (PDA), copper ions (Cu2⁺), and REDV peptides. The PDA‐based hydrophilic coating mimics the endothelial glycocalyx, reducing platelet adhesion, suppressing macrophage activation, and promoting M2 macrophage polarization. These effects, along with Cu‐catalyzed nitric oxide (NO) release, regulate thrombosis and inflammation, establishing a favorable microenvironment for vascular healing and regeneration. REDV peptides synergize with NO to selectively enhance endothelial cell (EC) adhesion, proliferation, and migration, enabling rapid endothelialization. The porous outer layer facilitates smooth muscle cell (SMC) infiltration, while NO inhibit excessive SMC proliferation, preventing restenosis. In vitro and in vivo studies, including implantation in Beagle dog iliac arteries, demonstrate that the graft achieves long‐term patency, superior hemocompatibility, and balanced tissue regeneration. This work offers a promising strategy to overcome current limitations in SDVGs, paving the way for advanced vascular repair and regeneration.


  • Near-Infrared Rechargeable Persistent Luminescence Nanoparticles for Biomedical Implants In Vivo Noninvasive Bioimaging

    by Daihua Fu, Fan Yang, Jiayi Zhang, Zhen Xiang, Yunbing Wang

    Luminescent imaging has garnered significant attention for in vivo tracking of biomedical implants during and after surgery due to its human friendliness, affordability, and high sensitivity. However, conventional fluorescent probes are susceptible to background autofluorescence interference from living tissues, often resulting in poor signal-to-noise ratios. Herein, we report a background interference-free persistent luminescent implant (PLI) with excellent persistent luminescence (PL) performance, which can be clearly and long-term detected by an optical imaging system after implantation. Rechargeable near-infrared persistent luminescence nanoparticles (PLNPs) were prepared first via a simple hydrothermal approach and then modified by PEGylation to improve their hydrophilicity, biocompatibility, and compatibility with polymer substrates. The PEGylated PLNPs were facilely complexed into a polymer matrix to fabricate the PLI. The obtained PLIs can well inherit the PL properties of PLNPs, exhibiting good PL optical imaging performance without tissue autofluorescence interference. Furthermore, both PLNPs and PLIs possess good biocompatibility, and the addition of PLNPs has no negative impact on the biocompatibility of the polymer matrix. This work fully utilizes the luminescent properties of PLNPs and adapts this PL to the field of biomedical implant imaging, which provides new insight for designing biomedical imaging systems.


  • Near-Infrared Remotely Controllable Shape Memory Biodegradable Occluder Based on Poly(l-lactide-co-ε-caprolactone)/Gold Nanorod Composite

    by Zhen Xiang, Jiayi Zhang, Chen Zhou, Bo Zhang, Nuoya Chen, Mingyu Li, Daihua Fu, Yunbing Wang

    Biodegradable occluders, which can efficiently eliminate the complications caused by permanent foreign implants, are considered to be the next-generation devices for the interventional treatment of congenital heart disease. However, the controllability of the deployment process of degradable occluders remains a challenge. In this work, a near-infrared (NIR) remotely controllable biodegradable occluder is explored by integrating poly(l-lactide-co-ε-caprolactone) (PLCL) with poly(ethylene glycol)-modified gold nanorods (GNR/PEG). The caprolactone structural units can effectively increase the toughness of poly(l-lactide) and reduce the shape-memory transition temperature of the occluder to a more tissue-friendly temperature. Gold nanorods endow the PLCL-GNR/PEG composite with an excellent photothermal effect. The obtained occluder can be easily loaded into a catheter for transport and spatiotemporally expanded under irradiation with near-infrared light to block the defect site. Both in vitro and in vivo biological experiments showed that PLCL-GNR/PEG composites have good biocompatibility, and the PEGylated gold nanorods could improve the hemocompatibility of the composites to a certain extent by enhancing their hydrophilicity. As a thermoplastic shape-memory polymer, PLCL-GNR/PEG can be easily processed into various forms and structures for different patients and lesions. Therefore, PLCL-GNR/PEG has the potential to be considered as a competitive biodegradable material not only for occluders but also for other biodegradable implants.