Chaowei Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chaowei Dong has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Deying Chen
National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150001, China
5 shared publications - Rongwei Fan
National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150001, China
5 shared publications - Zhaodong Chen
National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150001, China
5 shared publications - Lansong Cao
National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150001, China
3 shared publications - Zhiwei Dong
National Key Laboratory of Laser Spatial Information, Harbin Institute of Technology, Harbin 150001, China
3 shared publications - Pengfei Hao
Space Representative Office, Changchun 130000, China
2 shared publications
Latest Publications
- Open Access
- 4 August 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (8) , 355
Relative-Height Image Generation from Long-Range Airborne Streak-Tube Imaging LiDAR for Wide-Area Building- Structure Mapping
Wide-area building-structure mapping from long-range airborne LiDAR requires image products that can represent building footprints, roof-height variations, and structural discontinuities with low computational latency. Airborne streak-tube imaging LiDAR (ASTIL) records a spatial–temporal echo image for each laser pulse, where the detector row corresponds to the fan-beam spatial angle, the detector column encodes echo arrival time, and the frame sequence represents the scanning process. This row–column–frame topology makes it possible to generate image-domain structural products directly from raw streak-tube echo sequences. In this paper, a relative-height image generation method is proposed for long-range ASTIL. The method constructs slant-range matrices from raw echo images, suppresses row-wise ground-related range trends, maps the residuals into relative-height values, and generates scan-geometry-calibrated swath-level relative-height images using lightweight calibration rather than rigorous point-wise POS/IMU trajectory reconstruction. Airborne experiments at 2 km, 3 km, and 6 km flight heights show that the proposed workflow can generate relative-height images with spatial sampling intervals of 0.30 m, 0.45 m, and 0.90 m, respectively, within a 0.5 s acquisition window. The generated cropped image products occupy less than 0.3% of the raw streak-image sequence volume, reflecting a compact image-domain representation for rapid preliminary mapping rather than lossless data compression. Building-scale comparisons with UAV LiDAR reference data indicate that the generated images preserve the main building footprints, boundary orientations, and roof-height discontinuities. For nine flat-roof targets, the mean absolute roof-to-ground height errors range from 0.24 m to 0.30 m across the three flight heights. These results suggest that ASTIL relative-height imaging can provide an efficient image-domain representation for wide-area building-structure mapping under long-range airborne observation conditions.
- 4 August 2026
- Published by MDPI AG in Journal of Imaging
- Vol. 12 (8) , 355
Open AccessRelative-Height Image Generation from Long-Range Airborne Streak-Tube Imaging LiDAR for Wide-Area Building- Structure Mapping
Wide-area building-structure mapping from long-range airborne LiDAR requires image products that can represent building footprints, roof-height variations, and structural discontinuities with low computational latency. Airborne streak-tube imaging LiDAR (ASTIL) records a spatial–temporal echo image for each laser pulse, where the detector row corresponds to the fan-beam spatial angle, the detector column encodes echo arrival time, and the frame sequence represents the scanning process. This row–column–frame topology makes it possible to generate image-domain structural products directly from raw streak-tube echo sequences. In this paper, a relative-height image generation method is proposed for long-range ASTIL. The method constructs slant-range matrices from raw echo images, suppresses row-wise ground-related range trends, maps the residuals into relative-height values, and generates scan-geometry-calibrated swath-level relative-height images using lightweight calibration rather than rigorous point-wise POS/IMU trajectory reconstruction. Airborne experiments at 2 km, 3 km, and 6 km flight heights show that the proposed workflow can generate relative-height images with spatial sampling intervals of 0.30 m, 0.45 m, and 0.90 m, respectively, within a 0.5 s acquisition window. The generated cropped image products occupy less than 0.3% of the raw streak-image sequence volume, reflecting a compact image-domain representation for rapid preliminary mapping rather than lossless data compression. Building-scale comparisons with UAV LiDAR reference data indicate that the generated images preserve the main building footprints, boundary orientations, and roof-height discontinuities. For nine flat-roof targets, the mean absolute roof-to-ground height errors range from 0.24 m to 0.30 m across the three flight heights. These results suggest that ASTIL relative-height imaging can provide an efficient image-domain representation for wide-area building-structure mapping under long-range airborne observation conditions.
- Open Access
- 8 July 2026
- Published by MDPI AG in Remote Sensing
- Vol. 18 (14) , 2281
Lightweight Raw Echo Image Preprocessing for Long-Range Airborne Streak Tube Imaging LiDAR Using Adaptive Frequency-Domain Noise Suppression
Long-range airborne streak tube imaging lidar (ASTIL) raw echo images are degraded by atmospheric speckle, detector noise, and weak-return fluctuations, which can bias centroid localization before range calculation. This study presents a lightweight preprocessing method combining row–column geometry-aware echo region pre-classification with frequency-domain histogram-based adaptive suppression. Candidate regions are extracted from normalized streak images, classified by row–column morphology, filtered using local magnitude-spectrum percentile thresholds, and fused with a background-constrained weighted strategy. Simulated echo images, simulated point clouds, and 6 km airborne data were used for validation. In selected building roof control regions, the mean elevation root mean square error (RMSE) decreased from 0.34 m to 0.29 m, the mean absolute error (MAE) from 0.30 m to 0.26 m, and the mean roof elevation standard deviation from 0.19 m to 0.15 m, corresponding to an approximately 21% reduction in roof-level point cloud thickness. The results show that preprocessing before centroid extraction can improve roof-level vertical consistency without neural-network training or complex point cloud post-processing.
- 8 July 2026
- Published by MDPI AG in Remote Sensing
- Vol. 18 (14) , 2281
Open AccessLightweight Raw Echo Image Preprocessing for Long-Range Airborne Streak Tube Imaging LiDAR Using Adaptive Frequency-Domain Noise Suppression
Long-range airborne streak tube imaging lidar (ASTIL) raw echo images are degraded by atmospheric speckle, detector noise, and weak-return fluctuations, which can bias centroid localization before range calculation. This study presents a lightweight preprocessing method combining row–column geometry-aware echo region pre-classification with frequency-domain histogram-based adaptive suppression. Candidate regions are extracted from normalized streak images, classified by row–column morphology, filtered using local magnitude-spectrum percentile thresholds, and fused with a background-constrained weighted strategy. Simulated echo images, simulated point clouds, and 6 km airborne data were used for validation. In selected building roof control regions, the mean elevation root mean square error (RMSE) decreased from 0.34 m to 0.29 m, the mean absolute error (MAE) from 0.30 m to 0.26 m, and the mean roof elevation standard deviation from 0.19 m to 0.15 m, corresponding to an approximately 21% reduction in roof-level point cloud thickness. The results show that preprocessing before centroid extraction can improve roof-level vertical consistency without neural-network training or complex point cloud post-processing.
- Open Access
- 1 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 8835
Design and Validation of a Long-Range Streak-Tube Imaging Lidar System with High Ranging Accuracy
The Streak-Tube Imaging Lidar (STIL) has been widely used in high-precision measurement systems due to its ability to capture detailed spatial and temporal information. In this paper, we proposed a ranging measurement method that integrates a Time-to-Digital Converter (TDC) with a streak camera in a remote STIL system. In this method, the TDC accurately measures the trigger pulse time, while the streak camera captures high time-resolution images of the laser echo, thereby enhancing both measurement accuracy and range. A corresponding ranging model is developed for this method. To validate the system’s performance, an outdoor experiment covering a distance of up to 6 km was conducted. The results demonstrate that the system achieved a distance measurement accuracy of 0.1 m, highlighting its effectiveness in long-range applications. The experiment further confirms that the combination of STIL and TDC significantly enhances accuracy and range, making it suitable for various long-range, high-precision measurement tasks.
- 1 October 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (19) , 8835
Open AccessDesign and Validation of a Long-Range Streak-Tube Imaging Lidar System with High Ranging Accuracy
The Streak-Tube Imaging Lidar (STIL) has been widely used in high-precision measurement systems due to its ability to capture detailed spatial and temporal information. In this paper, we proposed a ranging measurement method that integrates a Time-to-Digital Converter (TDC) with a streak camera in a remote STIL system. In this method, the TDC accurately measures the trigger pulse time, while the streak camera captures high time-resolution images of the laser echo, thereby enhancing both measurement accuracy and range. A corresponding ranging model is developed for this method. To validate the system’s performance, an outdoor experiment covering a distance of up to 6 km was conducted. The results demonstrate that the system achieved a distance measurement accuracy of 0.1 m, highlighting its effectiveness in long-range applications. The experiment further confirms that the combination of STIL and TDC significantly enhances accuracy and range, making it suitable for various long-range, high-precision measurement tasks.
- Open Access
- 5 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (15) , 6843
High Accuracy Reconstruction of Airborne Streak Tube Imaging LiDAR Using Particle Swarm Optimization
Airborne streak tube imaging LiDAR (STIL) consists of several different data-generating subsystems and introduces system errors each time it is installed on an aircraft. These errors change with each installation, which makes the parametric calibration of the LiDAR meaningless. In this study, we propose a high-precision reconstruction method for point clouds that can be used without calibrating the system parameters. In essence, after each remote sensing measurement, a self-checking process is performed with experimental data to replace the fixed system parameters. In this process, the splicing error of the same region measured under different conditions is used as a criterion to optimize the reconstruction parameters via a particle swarm optimization (PSO) algorithm. For a detection distance of 3000 m, the elevation error of the point cloud reconstruction reaches more than 1 m if the placement parameters are not optimized; after optimization, the elevation error can be controlled within 0.3 m.
- 5 August 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (15) , 6843
Open AccessHigh Accuracy Reconstruction of Airborne Streak Tube Imaging LiDAR Using Particle Swarm Optimization
Airborne streak tube imaging LiDAR (STIL) consists of several different data-generating subsystems and introduces system errors each time it is installed on an aircraft. These errors change with each installation, which makes the parametric calibration of the LiDAR meaningless. In this study, we propose a high-precision reconstruction method for point clouds that can be used without calibrating the system parameters. In essence, after each remote sensing measurement, a self-checking process is performed with experimental data to replace the fixed system parameters. In this process, the splicing error of the same region measured under different conditions is used as a criterion to optimize the reconstruction parameters via a particle swarm optimization (PSO) algorithm. For a detection distance of 3000 m, the elevation error of the point cloud reconstruction reaches more than 1 m if the placement parameters are not optimized; after optimization, the elevation error can be controlled within 0.3 m.
- Open Access
- 6 September 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (18) , 10042
A Calibration Method for Time Dimension and Space Dimension of Streak Tube Imaging Lidar
Owing to the special working systems of streak tube imaging lidar (STIL), the time and space dimensions are coupled together on the streak images. This coupling can cause measurement errors in 3D point clouds and can make measurement results more complicated to calibrate than other kinds of lidars. This paper presents a method to generate a time calibration array and an angle calibration array to separate the offset of the streak into time dimension and space dimension. The time and space information of the signal at any position on the streak image can be indexed through these two arrays. A validation experiment on aircraft was carried out, and the range error of the 3D point cloud was improved from 0.41 m to 0.27 m using the proposed calibration method. Thus, using the proposed calibration method can improve the accuracy of the point cloud produced by STIL.
- 6 September 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (18) , 10042
Open AccessA Calibration Method for Time Dimension and Space Dimension of Streak Tube Imaging Lidar
Owing to the special working systems of streak tube imaging lidar (STIL), the time and space dimensions are coupled together on the streak images. This coupling can cause measurement errors in 3D point clouds and can make measurement results more complicated to calibrate than other kinds of lidars. This paper presents a method to generate a time calibration array and an angle calibration array to separate the offset of the streak into time dimension and space dimension. The time and space information of the signal at any position on the streak image can be indexed through these two arrays. A validation experiment on aircraft was carried out, and the range error of the 3D point cloud was improved from 0.41 m to 0.27 m using the proposed calibration method. Thus, using the proposed calibration method can improve the accuracy of the point cloud produced by STIL.