Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Moazzam Ali has a total of 19 co-authors. Here are the top co-authors by number of shared publications:

  • Ali Turab Jafry

    Faculty of Mechanical Engineering, Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi 23640, Pakistan

    5 shared publications
  • Hammas Ullah

    Faculty of Mechanical Engineering, Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi 23460, Pakistan

    3 shared publications
  • Hamza Abbas

    Faculty of Mechanical Engineering, Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi 23460, Pakistan

    3 shared publications
  • Huma Ajab

    Department of Chemistry, COMSATS University Islamabad, Abbottabad Campus, Pakistan

    3 shared publications
  • Mubashar Ali

    Faculty of Mechanical Engineering, Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi 23460, Pakistan

    3 shared publications
  • Hammas Ullah

    Faculty of Mechanical Engineering, Ghulam Ishaq Khan Institute of Engineering Sciences and Technology, Topi 23460, Pakistan

    2 shared publications

Latest Publications

  • Open Access

    Influence of Inclined Chip Angles on Dynamic Contact Angle Variations in Digital Microfluidics

    by Moazzam Ali, Hammas Ullah, Hamza Javaid, Nauman Naeem, Ali Turab Jafry, Huma Ajab

    The impact of tilted angles on contact angles of water droplets in digital microfluidics was investigated. Experiments were conducted tilting the chip from 0 to 10 degrees at voltage increments of 50V from 250V to 400V DC. Both advancing and receding contact angles of the water droplets were measured at each angle and voltage combination. As the tilted angle increased from horizontal to 10 degrees, the advancing contact angle generally decreased whereas the receding contact angle increased. This trend held for all tested voltages. The changes were more pronounced at higher tilt angles above 5 degrees. Voltage was also found to influence the contact angles, with both advancing and receding angles decreasing with increasing driving voltage. The results provide insight into how tilted surface angles affect wetting properties in digital microfluidics. By understanding these relationships between contact angles, tilt angles and driving voltages, design parameters like maximum operational tilt angles before droplet pinning or instability can be better determined. The findings may assist in designing and optimizing tilted or three-dimensional digital microfluidic devices and applications.

  • Open Access

    Droplet Actuation Enhancement through Voltage Control and Hydrophobic Coating Selection

    by Hammas Ullah, Moazzam Ali, Nauman Naeem, Faisal Iqbal, Hamza Abbas, Ali Turab Jafry, Huma Ajab

    This paper presents a novel digital microfluidics platform that utilizes PCB substrate designed on Easy EDA software and is based on electrowetting on a dielectric (EWOD) phenomenon. For droplet actuation, the platform’s performance was examined at different DC voltages ranging from 300V to 450V. The fabrication process was made simple and inexpensive by using readily available, low-cost ingredients including silicone oil, cooking oil, and olive oil with grafting tape as a dielectric layer. Compared to other oils used for droplet actuation, cooking oil yields the highest droplet velocity. Due to its affordable and easy-to-fabricate nature, our suggested digital microfluidics platform will be feasible for droplet actuation and can also be applied to medical diagnostic applications like DNA analysis and cell culture, as well as the detection of environmental pollutants.


  • Open Access

    Influence of nano additives on Diesel-Biodiesel fuel blends in diesel engine: A spray, performance, and emissions study

    by Muteeb Ul Haq, Ali Turab Jafry, Moazzam Ali, Huma Ajab, Naseem Abbas, Uzair Sajjad, Khalid Hamid


  • Open Access

    Dynamic Contact Angle Variation with Applied Voltage and Droplet Volume in Digital Microfluidics

    by Moazzam Ali, Hammas Ullah, Mubashar Ali, Nauman Naeem, Hamza Abbas, Ali Turab Jafry

    Digital microfluidics allows for controlled droplet movement by applying AC or DC voltages. In this research, we investigated the dynamic contact angle variation of droplets at different voltages and droplet volumes in a digital microfluidics platform. Volumes of 10 µL, 14 µL, and 18 µL were investigated with voltages ranging from 250 V to 400 V. The goal was to investigate how variations in voltage and droplet volume affected the contact angle, specifically by tracking variations in the advancing and receding contact angles. The findings showed that as voltage rises, the contact angle decreases more noticeably in terms of both advancing and receding angles. This shows that higher voltages boost the electrowetting effect and lead to better droplet dispersal and substrate wetting. Furthermore, it was found that across the studied voltage range, the effect of volume on the contact angle was largely consistent. The relation between voltage, volume, and contact angle in electrowetting is better understood from our analysis.


  • Open Access

    Design and Fabrication of Digital Microfluidics device for Lab-on-a-Chip Applications

    by Hammas Ullah, Faraz Shoaib, Syed Danyal Zahid, Mohammad Iymaan Mahmood, Mubashar Ali, Moazzam Ali, Hamza Abbas, Ali Turab Jafry

    In digital microfluidics, discrete liquid droplets move on a dielectric surface with the help of AC or DC voltage. Digital microfluidics system has extended the scope of microfluidics by providing automated, precise flow control for point-of-care devices capable of medical diagnostics, environmental, and chemical sensing platforms. In this paper, we introduce a digital microfluidics platform based on electrowetting on a dielectric using PCB substrate designed on Easy EDA software. The platform’s performance was analyzed at various DC voltages between 200 V and 400 V for droplet actuation. PCB fabrication, the utilization of easily accessible and cheap materials such as cooking oil and grafting tape as a dielectric layer, allowed the fabrication to be affordable and simple. The results indicate that droplet actuation takes place at 220 V. The droplet velocity obtained was 2.6 mm/s and 1.51 mm/s using silicon oil and cooking oil, respectively, at 400 V. Our proposed digital microfluidics platform will play a vital role in droplet actuation and can be used for diagnostic applications such as DNA analysis and cell culture due to its simple fabrication and cost-effective technique.


  • Open Access

    Effect of Storage Reservoir on Fluid Velocity in Lateral Flow Paper Device

    by Hamza Abbas, Mubashar Ali, Nauman Naeem, Hammas Ullah, Moazzam Ali, Ali Turab Jafry

    Paper-based microfluidics provides a versatile platform for numerous applications, including diagnostics at the point of care, environmental detection, and food quality control. Utilizing paper as a substrate offers numerous benefits, including flexibility, biodegradability, low cost, and capillary-driven flow. Despite significant advancements in paper-based microfluidic devices, regulating fluid flow effectively within the paper channel remains a persistent challenge. In order to resolve this problem, our research proposes a method for manipulating fluid flow in the paper channel by altering the surface contact between the storage medium and the paper channel. According to the results, increasing the contact area between the reservoir and the paper surface decreases the flow velocity and increases the fluidic time delay. This is due to the increased diffusion area between the storage medium and the paper channel, which creates resistance to liquid flow. Therefore, the liquid takes longer to travel through the paper channel, resulting in a decrease in velocity relative to contact areas of 50% or 70%. We are confident that this method of flow control can enable lateral flow sensing devices with enhanced flow variation options for use in medical, environmental, or food quality applications.