YYYimin You

Yimin You

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yimin You has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electric Field Improvement and Insulation Performance Enhancement of a Compact 40.5 kV Eco-Friendly Gas-Insulated Switchgear

    by Dongyun Dai, Yuhao Zhang, Yimin You, Zehong Lin, Xiangzhong Liao

    With the ongoing trend of miniaturization and intelligent power transmission equipment, the compact design of environmentally friendly gas-insulated switchgear (GIS) has emerged as a critical technical challenge. This study presents a detailed case study of a 40.5 kV dry air-insulated switchgear under specific dimensional constraints. Specifically, the cabinet width was reduced from 1000 mm to 800 mm, significantly narrowing the phase-to-phase and phase-to-ground clearances. A high-fidelity three-dimensional electric field model was established using the finite element method to evaluate the dielectric stress distribution within the enclosure. Numerical results indicate pronounced electric field concentrations at critical regions—including copper busbar joints, disconnector contacts, and the inlet bushing shielding rings—where local intensities exceeded the insulation safety threshold. To mitigate these issues, integrated design refinement strategies were evaluated, encompassing the structural modification of shielding rings, the application of silicone rubber coatings, and insulation reinforcement via heat-shrinkable tubing. Comparative analysis and experimental results demonstrate that the refined configuration effectively suppressed the peak electric field intensity. Finally, the design was validated through comprehensive dielectric tests, including a 215 kV lightning impulse withstand voltage test. This work may offer useful engineering references and quantitative data for the ultra-compact design of eco-friendly switchgear under similar constraints.


  • Open Access

    Optimized Design of Permanent Magnet Trip Device Based on Orthogonal Experiments and BP-NSGA-II

    by Jie Zhang, Yimin You, Kaicai Zhuo, Lu Zhu, Dongyun Dai, Jun Xiao, Junxiang Liu, Yong Wang

    To address the issues of slow operation and high variability in traditional electromagnetic trip devices, this paper proposes a magnetic trip device based on the principle of “permanent magnet holding, spring driving, and electric reset,” thereby reducing the circuit breaker tripping time. However, its high material and manufacturing costs have limited its widespread adoption. To address this issue, this paper employs a method combining orthogonal experiments with BP-NSGA-II. Using permanent magnet dimensions, coil wire gauge, moving component mass, and spring initial force as variables, the number of simulations is reduced through orthogonal experiments, and transient electromagnetic simulation is utilized to analyze the trip mechanism’s dynamic performance; a BP neural network surrogate model was constructed to replace finite element simulation, and the NSGA-II algorithm was employed to perform weightless Pareto optimization, with the volume of the permanent magnet and the amount of copper used in the coil as the cost optimization objectives. Under the constraint of a trip time ≤ 15 ms, the permanent magnet dimensions were reduced from 8 × 44 × 5 mm to 6.5 × 44 × 5 mm (a 18.7% reduction in volume), and the coil wire diameter was optimized from 0.18 mm (2000 turns) to 0.14 mm (1400 turns) (a 22.3% reduction in copper usage). Test results show that the optimized trip time was reduced from 16.0 ms to 14.1 ms, with the prototype measuring 14.56 ms in actual testing; the discrepancy between the simulation and experiment was less than 5%. This method provides a reference for the design of a permanent magnet trip device and holds significant engineering value.

  • Open Access

    Audio General Recognition of Partial Discharge and Mechanical Defects in Switchgear Using a Smartphone

    by Dongyun Dai, Quanchang Liao, Zhongqing Sang, Yimin You, Rui Qiao, Huisheng Yuan

    Mechanical defects and partial discharge (PD) defects can appear in the indoor switchgear of substations or distribution stations, making the switchgear a safety hazard. However, traditional acoustic methods detect and identify these two types of defects separately, ignoring the general recognition of audio signals. In addition, the process of using testing equipment is complex and costly, which is not conducive to timely testing and widespread application. To assist technicians in making a quick preliminary diagnosis of defect types for switchgear, improve the efficiency of the subsequent overhaul, and reduce the cost of detection, this paper proposes a general audio recognition method for identifying defects in switchgear using a smartphone. Using this method, we can analyze and identify audio and video files recorded with smartphones and synchronously distinguish background noise, mechanical vibration, and PD audio signals, which have good applicability within a certain range. When testing the feasibility of using smartphones to identify three types of audio signal, through characterizing 12 sets of live audio and video files provided by technicians, it was found that there were similarities and differences in these characteristics, such as the autocorrelation, density, and steepness of the waveforms in the time domain, and the band energy and harmonic components of the frequency spectrum, and new combinations of features were proposed as applicable. To compare the recognition performance for features in the time domain, frequency band energy, Mel-frequency cepstral coefficient (MFCC), and this method, feature vectors were input into a support vector machine (SVM) for a recognition test, and the recognition results showed that the the present method had the highest recognition accuracy. Finally, a set of mechanical defects and PD defects were set up for a switchgear, for practical verification, which proved that this method was general and effective.