Stefania Valeria Fields
Stefania Valeria Fields has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Antonio Leccisotti
Siena Eye Laser, 53036 Poggibonsi, Italy
6 shared publications - Christian Crudale
Siena Eye Laser, 53036 Poggibonsi, Italy
5 shared publications - Giuseppe De Bartolo
Siena Eye Laser, 53036 Poggibonsi, Italy
5 shared publications - Matteo Posarelli
Siena Eye Laser, 53036 Poggibonsi, Italy
4 shared publications - Lorenzo Azzaro
Siena Eye Laser, 53036 Poggibonsi, Italy
1 shared publication - Matteo Posarelli
Siena Eye Laser, UK
1 shared publication
Latest Publications
- Open Access
- 26 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (17) , 6585
Safety and Efficacy of Keratorefractive Lenticule Extraction (KLEx) for High Myopia with the CLEAR Platform
Objectives: To assess the safety and efficacy of Keratorefractive Lenticule Extraction (KLEx) in patients with myopia ≥ 5 diopters (D). Methods: Retrospective study of KLEx procedures performed at Siena Eye Laser (Poggibonsi, Italy) with the CLEAR platform of the Ziemer Z8 femtosecond laser. Results: We included 137 eyes of 85 patients; mean age was 33.8 ± 8.3 years. Assessment at baseline showed a mean myopic error of −7.3 ± 1.4 D, a mean astigmatic error of 1.1 ± 0.8 D, and a mean spherical equivalent (SE) of −7.8 ± 1.6 D. Preoperative corrected distance visual acuity (CDVA) was 0.0 logMAR or better in all eyes. Mean corneal thickness was 510.0 ± 26.9 µm. At post-operative day 1 (POD1) uncorrected distance visual acuity (UDVA) was 0.1 ± 0.1 logMAR, with a mean residual SEQ of 0.1 ± 0.8 D. At 6 months follow-up, mean UDVA significantly increased to 0.0 ± 0.0 logMAR (p < 0.001), with a mean residual SE of −0.12 ± 0.7 D (p > 0.05 compared to POD1). At 24 months, the mean UDVA remained stable at 0.0 ± 0.0 logMAR, with a mean residual SE of −0.1 ± 0.4 D as manifest refraction (all p > 0.05 compared to 6 months). At 6 months and 2 years, the observed residual stromal bed (RSB) was 30 microns thicker than the RSB calculated by the Ziemer LDV Z8 software 2022. The difference between predicted (POZ) and effective (EOZ) optical zone correlated with the degree of myopia corrected (r = 0.6, p < 0.001). The difference between POZ and EOZ inversely correlated with astigmatic correction (r = −0.5, p < 0.001). Conclusions: In patients with high myopia, CLEAR showed good predictability and efficacy. Both UDVA and SE improved during the first 6 months, and remained stable at 2 years. The effective RSB was thicker than expected, and patients with high astigmatism achieved a larger EOZ.
- 26 August 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (17) , 6585
Open AccessSafety and Efficacy of Keratorefractive Lenticule Extraction (KLEx) for High Myopia with the CLEAR Platform
Objectives: To assess the safety and efficacy of Keratorefractive Lenticule Extraction (KLEx) in patients with myopia ≥ 5 diopters (D). Methods: Retrospective study of KLEx procedures performed at Siena Eye Laser (Poggibonsi, Italy) with the CLEAR platform of the Ziemer Z8 femtosecond laser. Results: We included 137 eyes of 85 patients; mean age was 33.8 ± 8.3 years. Assessment at baseline showed a mean myopic error of −7.3 ± 1.4 D, a mean astigmatic error of 1.1 ± 0.8 D, and a mean spherical equivalent (SE) of −7.8 ± 1.6 D. Preoperative corrected distance visual acuity (CDVA) was 0.0 logMAR or better in all eyes. Mean corneal thickness was 510.0 ± 26.9 µm. At post-operative day 1 (POD1) uncorrected distance visual acuity (UDVA) was 0.1 ± 0.1 logMAR, with a mean residual SEQ of 0.1 ± 0.8 D. At 6 months follow-up, mean UDVA significantly increased to 0.0 ± 0.0 logMAR (p < 0.001), with a mean residual SE of −0.12 ± 0.7 D (p > 0.05 compared to POD1). At 24 months, the mean UDVA remained stable at 0.0 ± 0.0 logMAR, with a mean residual SE of −0.1 ± 0.4 D as manifest refraction (all p > 0.05 compared to 6 months). At 6 months and 2 years, the observed residual stromal bed (RSB) was 30 microns thicker than the RSB calculated by the Ziemer LDV Z8 software 2022. The difference between predicted (POZ) and effective (EOZ) optical zone correlated with the degree of myopia corrected (r = 0.6, p < 0.001). The difference between POZ and EOZ inversely correlated with astigmatic correction (r = −0.5, p < 0.001). Conclusions: In patients with high myopia, CLEAR showed good predictability and efficacy. Both UDVA and SE improved during the first 6 months, and remained stable at 2 years. The effective RSB was thicker than expected, and patients with high astigmatism achieved a larger EOZ.
- Open Access
- 7 February 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (4) , 1067
Optical Coherence Tomography in Infectious Keratitis After Femtosecond Keratorefractive Surgery
Objectives: Anterior Segment Optical coherence tomography (AS–OCT) can help in the diagnosis and treatment of infectious keratitis, but it has not been studied in cases occurring after corneal refractive surgery procedures such as femtosecond laser in situ keratomileusis (FS–LASIK) and keratorefractive lenticule extraction (KLEx). In these procedures, a surgical interface is created, where infections usually start, thus determining a different AS–OCT pattern compared to non–surgical infections, which begin on the corneal surface. Methods: We retrospectively reviewed 22,756 eyes of 13,564 patients who underwent FS–LASIK and KLEx at our surgical center. Results: Four cases of post–refractive surgery infectious keratitis were included (two after FS–LASIK and two after KLEx), in which the AS–OCT identified an initial infiltrate in the interface, followed by interface inflammation. In one case, after FS–LASIK, interface fluid accumulation occurred. In one case, after KLEx, diffuse interface inflammation led to stromal reabsorption, later compensated by stromal reformation and epithelial hyperplasia, well documented by OCT. Conclusions: AS–OCT represents a useful tool for assessing corneal infections after refractive surgery, guiding the treatment, and evaluating the healing process and residual corneal scarring.
- 7 February 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (4) , 1067
Open AccessOptical Coherence Tomography in Infectious Keratitis After Femtosecond Keratorefractive Surgery
Objectives: Anterior Segment Optical coherence tomography (AS–OCT) can help in the diagnosis and treatment of infectious keratitis, but it has not been studied in cases occurring after corneal refractive surgery procedures such as femtosecond laser in situ keratomileusis (FS–LASIK) and keratorefractive lenticule extraction (KLEx). In these procedures, a surgical interface is created, where infections usually start, thus determining a different AS–OCT pattern compared to non–surgical infections, which begin on the corneal surface. Methods: We retrospectively reviewed 22,756 eyes of 13,564 patients who underwent FS–LASIK and KLEx at our surgical center. Results: Four cases of post–refractive surgery infectious keratitis were included (two after FS–LASIK and two after KLEx), in which the AS–OCT identified an initial infiltrate in the interface, followed by interface inflammation. In one case, after FS–LASIK, interface fluid accumulation occurred. In one case, after KLEx, diffuse interface inflammation led to stromal reabsorption, later compensated by stromal reformation and epithelial hyperplasia, well documented by OCT. Conclusions: AS–OCT represents a useful tool for assessing corneal infections after refractive surgery, guiding the treatment, and evaluating the healing process and residual corneal scarring.
- Open Access
- 13 June 2024
- Published by MDPI AG in Preprints.org
Optical Coherence Tomography in Infectious Keratitis after Femtosecond Keratorefractive Surgery
Optical coherence tomography (OCT) can help in the diagnosis and treatment of infectious keratitis, but it has not been studied in cases occurring after corneal refractive surgery procedures such as femtosecond laser in situ keratomileusis (FS-LASIK) and keratorefractive lenticule extraction (KLEx). In these procedures a surgical interface is created, where infections usually start, thus determining a different OCT pattern compared to non-surgical infections, which instead begin in the corneal surface. A total of 4 cases of post-refractive surgery infectious keratitis are reported (2 after FS-LASIK and 2 after KLEx), in which the OCT identified an initial infiltrate in the interface, followed by interface inflammation. In 1 case after FS-LASIK, interface fluid accumulation occurred. In 1 case after KLEx, diffuse interface inflammation led to stromal reabsorption, later compensated by stromal reformation and epithelial hyperplasia, well documented by OCT.
- 13 June 2024
- Published by MDPI AG in Preprints.org
Open AccessOptical Coherence Tomography in Infectious Keratitis after Femtosecond Keratorefractive Surgery
Optical coherence tomography (OCT) can help in the diagnosis and treatment of infectious keratitis, but it has not been studied in cases occurring after corneal refractive surgery procedures such as femtosecond laser in situ keratomileusis (FS-LASIK) and keratorefractive lenticule extraction (KLEx). In these procedures a surgical interface is created, where infections usually start, thus determining a different OCT pattern compared to non-surgical infections, which instead begin in the corneal surface. A total of 4 cases of post-refractive surgery infectious keratitis are reported (2 after FS-LASIK and 2 after KLEx), in which the OCT identified an initial infiltrate in the interface, followed by interface inflammation. In 1 case after FS-LASIK, interface fluid accumulation occurred. In 1 case after KLEx, diffuse interface inflammation led to stromal reabsorption, later compensated by stromal reformation and epithelial hyperplasia, well documented by OCT.
- Open Access
Creation of a Corneal Flap for Laser In Situ Keratomileusis Using a Three-Dimensional Femtosecond Laser Cut: Clinical and Optical Coherence Tomography Features
Laser in situ keratomileusis (LASIK) is the most frequently used technique for the surgical correction of refractive errors on the cornea. It entails the creation of a superficial hinged corneal flap using a femtosecond laser, ablation of the underlying stromal bed using an excimer laser, and repositioning of the flap. A corneal flap with an angled side cut reduces the risk of flap dislocation and infiltration of epithelial cells and confers unique biomechanical properties to the cornea. A new laser software creating three-dimensional (3D) flaps using a custom angle side cut was retrospectively evaluated, comparing optical coherence tomography 3D (with intended 90° side cut) and 2D flaps (with tapered side cuts) as well as respective intra- and early postoperative complications. Four hundred consecutive eyes were included, two hundred for each group. In the 3D group, the mean edge angle was 92°, and the procedure was on average 5.2 s slower (p = 0). Non-visually significant flap folds were found in thirteen eyes of the 2D group and in seven eyes of the 3D group (p = 0.17). In conclusion, the creation of a LASIK flap using a 3D femtosecond laser cut, although slightly slower, was safe and effective. The side cut angle was predictable and accurate.
Open AccessCreation of a Corneal Flap for Laser In Situ Keratomileusis Using a Three-Dimensional Femtosecond Laser Cut: Clinical and Optical Coherence Tomography Features
Laser in situ keratomileusis (LASIK) is the most frequently used technique for the surgical correction of refractive errors on the cornea. It entails the creation of a superficial hinged corneal flap using a femtosecond laser, ablation of the underlying stromal bed using an excimer laser, and repositioning of the flap. A corneal flap with an angled side cut reduces the risk of flap dislocation and infiltration of epithelial cells and confers unique biomechanical properties to the cornea. A new laser software creating three-dimensional (3D) flaps using a custom angle side cut was retrospectively evaluated, comparing optical coherence tomography 3D (with intended 90° side cut) and 2D flaps (with tapered side cuts) as well as respective intra- and early postoperative complications. Four hundred consecutive eyes were included, two hundred for each group. In the 3D group, the mean edge angle was 92°, and the procedure was on average 5.2 s slower (p = 0). Non-visually significant flap folds were found in thirteen eyes of the 2D group and in seven eyes of the 3D group (p = 0.17). In conclusion, the creation of a LASIK flap using a 3D femtosecond laser cut, although slightly slower, was safe and effective. The side cut angle was predictable and accurate.
- Open Access
- 28 March 2024
- Published by MDPI AG in Preprints.org
Creation of the Corneal Flap for Laser In Situ Keratomileusis with a 3-Dimension Femtosecond Laser Cut: Clinical and Optical Coherence Tomography Features
Laser in situ keratomileusis (LASIK) is the gold standard in the surgical correction of refractive errors on the cornea. It entails the creation of a superficial hinged corneal flap by a femtosecond laser, ablation of the underlying stromal bed by an excimer laser, and reposition of the flap. The corneal flap can be build in a 2-dimension (2D) fashion with tapered edges, or in a 3-dimension (3D) fashion, with angled sidecut. The latter reduces the risk of flap dislocation and infiltration of epithelial cells. This retrospective study compares with optical coherence tomography 3D and 2D flaps, and respective intra- and early post-operative complications. Four hundred consecutive eyes were included, 200 for each group. In the 3D group, the mean edge angle was 92°. The procedure was in average 5.2 seconds slower in the 3D group (p=0). Non visually significant flap folds were found in 13 eyes of the 2D group and in 7 eyes of the 3D group (p= 0.17). An intracorneal opaque bubble layer induced by laser photodisruption was more commonly observed in the 3D group (9 eyes vs. 2; p=0.03). In conclusion, the creation of a LASIK flap by a 3D-femtosecond laser cut was safe and effective.
- 28 March 2024
- Published by MDPI AG in Preprints.org
Open AccessCreation of the Corneal Flap for Laser In Situ Keratomileusis with a 3-Dimension Femtosecond Laser Cut: Clinical and Optical Coherence Tomography Features
Laser in situ keratomileusis (LASIK) is the gold standard in the surgical correction of refractive errors on the cornea. It entails the creation of a superficial hinged corneal flap by a femtosecond laser, ablation of the underlying stromal bed by an excimer laser, and reposition of the flap. The corneal flap can be build in a 2-dimension (2D) fashion with tapered edges, or in a 3-dimension (3D) fashion, with angled sidecut. The latter reduces the risk of flap dislocation and infiltration of epithelial cells. This retrospective study compares with optical coherence tomography 3D and 2D flaps, and respective intra- and early post-operative complications. Four hundred consecutive eyes were included, 200 for each group. In the 3D group, the mean edge angle was 92°. The procedure was in average 5.2 seconds slower in the 3D group (p=0). Non visually significant flap folds were found in 13 eyes of the 2D group and in 7 eyes of the 3D group (p= 0.17). An intracorneal opaque bubble layer induced by laser photodisruption was more commonly observed in the 3D group (9 eyes vs. 2; p=0.03). In conclusion, the creation of a LASIK flap by a 3D-femtosecond laser cut was safe and effective.
- Open Access
- 18 April 2023
- Published by PAGEPress Publications in Laser Therapy
- Vol. 30 (1)
Incidence and outcome of suction loss during corneal lenticule extraction with the femtosecond laser application CLEAR
- 18 April 2023
- Published by PAGEPress Publications in Laser Therapy
- Vol. 30 (1)
Open AccessIncidence and outcome of suction loss during corneal lenticule extraction with the femtosecond laser application CLEAR