Mochamad Iqbal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Mochamad Iqbal has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Bella Restu Juliarka
Petrology, Volcanology, and Geothermal Research Group, Geological Engineering, Institut Teknologi Sumatera, Jalan Terusan Ryacudu, Way Huwi, 36365, Lampung, Indonesia
2 shared publicationsBilal Al Farishi
Geology Research Group, Geological Engineering, Institut Teknologi Sumatera
2 shared publications- Katsuaki Koike
Department of Urban Management, Graduate School of Engineering, Kyoto University
2 shared publications - Koki Kashiwaya
Department of Urban Management, Graduate School of Engineering, Kyoto University, Kyoto, Japan
2 shared publications Rahmat Nawi Siregar
2 shared publications- Rofiqul Umam
Faculty of Life and Environmental Sciences, University of Tsukuba Japan // Center for Research in Radiation, Isotopes, and Earth System Sciences (CRiES), University of Tsukuba, Japan
2 shared publications
Latest Publications
- Open Access
- 20 April 2026
- Published by Elsevier in SSRN Electronic Journal
Detecting and characterizing a hidden geothermal system in the Mt. Endut area, Indonesia, through integrated soil-gas component analyses
A hidden geothermal system (HGS) is a specific, complex geothermal system that does not have surface thermal manifestations but has significant potential for energy resources. Despite the difficulty of exploration of such systems because of their concealed features, detection and development of these systems can significantly contribute to increasing geothermal power generation. This study aimed to detect and characterize an HGS in the Mt. Endut area, Banten, west Indonesia, and to clarify its relationship with the adjacent, conventional mediumtemperature Cikawah Geothermal System (CGS). Mt. Endut area is classified as a hidden system because a thick low-permeability cap rock and sealed fault segments suppress surface discharge, with no evidence of a depressed water table or an overlying cold aquifer. Under such sealing conditions, moderately low-solubility CO2 and short-lived radon isotopes (222 Rn and 220 Rn) can migrate upward through minor fractures while liquid flow remains impeded, making them effective tracers of concealed fluid pathways. To evaluate this mechanism, an integrated soil-gas geochemical approach was employed, combining CO2 flux, δ 13 C-CO2, and radon isotopes measurements with interpretations from existing geophysical datasets, a complete Bouguer anomaly (CBA) map, and magnetotelluric (MT) data. The soil-gas survey revealed large variabilities in the CO2 flux (15 to 1,399 g m-2 day-1) and δ 13 C-CO2 (-18.71 to-9.75‰) caused by a complex mixture of biogenic and hydrothermal gas sources. The locations of highflux zones of hydrothermal-dominated mixture (HDM) CO2 were strongly correlated with the Handeleum dextral fault having a permeable structure. The 222 Rn/ 220 Rn ratio was effective for differentiating gas source depths and attributing deep-seated 222 Rn anomalies to major fault zones and advective transport. A key finding was the role of the NNE-SSW Endut normal fault as a distinct structural boundary separating the Endut HGS from the CGS, supported by a coincident gravity low and a steep MT resistivity gradient. Moreover, the results suggest that the two systems are driven by distinct heat sources, a deep magmatic body for the Endut HGS
- 20 April 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessDetecting and characterizing a hidden geothermal system in the Mt. Endut area, Indonesia, through integrated soil-gas component analyses
A hidden geothermal system (HGS) is a specific, complex geothermal system that does not have surface thermal manifestations but has significant potential for energy resources. Despite the difficulty of exploration of such systems because of their concealed features, detection and development of these systems can significantly contribute to increasing geothermal power generation. This study aimed to detect and characterize an HGS in the Mt. Endut area, Banten, west Indonesia, and to clarify its relationship with the adjacent, conventional mediumtemperature Cikawah Geothermal System (CGS). Mt. Endut area is classified as a hidden system because a thick low-permeability cap rock and sealed fault segments suppress surface discharge, with no evidence of a depressed water table or an overlying cold aquifer. Under such sealing conditions, moderately low-solubility CO2 and short-lived radon isotopes (222 Rn and 220 Rn) can migrate upward through minor fractures while liquid flow remains impeded, making them effective tracers of concealed fluid pathways. To evaluate this mechanism, an integrated soil-gas geochemical approach was employed, combining CO2 flux, δ 13 C-CO2, and radon isotopes measurements with interpretations from existing geophysical datasets, a complete Bouguer anomaly (CBA) map, and magnetotelluric (MT) data. The soil-gas survey revealed large variabilities in the CO2 flux (15 to 1,399 g m-2 day-1) and δ 13 C-CO2 (-18.71 to-9.75‰) caused by a complex mixture of biogenic and hydrothermal gas sources. The locations of highflux zones of hydrothermal-dominated mixture (HDM) CO2 were strongly correlated with the Handeleum dextral fault having a permeable structure. The 222 Rn/ 220 Rn ratio was effective for differentiating gas source depths and attributing deep-seated 222 Rn anomalies to major fault zones and advective transport. A key finding was the role of the NNE-SSW Endut normal fault as a distinct structural boundary separating the Endut HGS from the CGS, supported by a coincident gravity low and a steep MT resistivity gradient. Moreover, the results suggest that the two systems are driven by distinct heat sources, a deep magmatic body for the Endut HGS
- 28 January 2026
- Published by Elsevier in Measurement
- Vol. 267
Reliability testing and verification of a portable CO2 flux measurement device for geothermal and volcanic studies
- 28 January 2026
- Published by Elsevier in Measurement
- Vol. 267
Reliability testing and verification of a portable CO2 flux measurement device for geothermal and volcanic studies
- Open Access
- 22 September 2025
- Published by Elsevier in Geothermics
- Vol. 134
Lithium enrichment in high radiogenic geothermal systems originating from lithospheric water due to water-rock interactions
- 22 September 2025
- Published by Elsevier in Geothermics
- Vol. 134
Open AccessLithium enrichment in high radiogenic geothermal systems originating from lithospheric water due to water-rock interactions
- Open Access
- 30 November 2024
- Published by National Research and Innovation Agency in EKSPLORIUM
- Vol. 45 (2) , 67-76
Evaluating The Effectiveness of Radon Measurement Techniques in Soil Gas: Impact of Hole Depth and Measurement Time
Radon measurement methodologies are critical for accurate risk assessment and resource optimization, yet challenges persist in determining the optimal sampling depth and measurement duration. These factors significantly influence radon concentration readings, and their impact still needs to be explored in systematic evaluations, particularly in balancing efficiency and accuracy. This study evaluates the effectiveness of radon measurement methodologies by experimenting with how sampling hole depth and measurement duration affect radon concentration in soil gas. Radon experiments were conducted at depths of 0.5 m, 1.0 m, and 1.2 m over a 39-day period in soft tuff rock formations at Institut Teknologi Sumatera. Measurements were taken on Days 0, 6, 12, 18, 27, and 39 using the RAD7 Radon Detector, with multiple cycles to ensure stability. The results indicate that radon concentrations varied significantly with both depth and time, with the highest concentrations observed at 1.2 m on Day 18 (1,089 Bq/m³). A noticeable “lag effect” was observed following rainfall events, where radon levels initially decreased due to soil saturation but spiked as the soil dried. The depth of 0.5 m provided the most consistent measurements, with the lowest coefficient of variation (CV = 31%), making it the most reliable and practical depth for routine radon assessments. Overall, this study highlights the importance of considering environmental conditions, such as rainfall and soil moisture, when interpreting radon data and provides insights into optimizing radon measurement practices for accuracy and efficiency.
- 30 November 2024
- Published by National Research and Innovation Agency in EKSPLORIUM
- Vol. 45 (2) , 67-76
Open AccessEvaluating The Effectiveness of Radon Measurement Techniques in Soil Gas: Impact of Hole Depth and Measurement Time
Radon measurement methodologies are critical for accurate risk assessment and resource optimization, yet challenges persist in determining the optimal sampling depth and measurement duration. These factors significantly influence radon concentration readings, and their impact still needs to be explored in systematic evaluations, particularly in balancing efficiency and accuracy. This study evaluates the effectiveness of radon measurement methodologies by experimenting with how sampling hole depth and measurement duration affect radon concentration in soil gas. Radon experiments were conducted at depths of 0.5 m, 1.0 m, and 1.2 m over a 39-day period in soft tuff rock formations at Institut Teknologi Sumatera. Measurements were taken on Days 0, 6, 12, 18, 27, and 39 using the RAD7 Radon Detector, with multiple cycles to ensure stability. The results indicate that radon concentrations varied significantly with both depth and time, with the highest concentrations observed at 1.2 m on Day 18 (1,089 Bq/m³). A noticeable “lag effect” was observed following rainfall events, where radon levels initially decreased due to soil saturation but spiked as the soil dried. The depth of 0.5 m provided the most consistent measurements, with the lowest coefficient of variation (CV = 31%), making it the most reliable and practical depth for routine radon assessments. Overall, this study highlights the importance of considering environmental conditions, such as rainfall and soil moisture, when interpreting radon data and provides insights into optimizing radon measurement practices for accuracy and efficiency.
- Open Access
- 26 May 2024
- Published by Qeios Ltd
Review of: "Exploration of Quartz, Feldspar, and Mica Minerals Using Geophysical Resistivity, Self-Potential, and Natural Electrical Field Techniques"
The paper presents interesting findings; however, I believe there are several areas that could benefit from further improvement to enhance its overall quality and impact. Firstly, I recommend a more thorough development of each section, with particu...
- 26 May 2024
- Published by Qeios Ltd
Open AccessReview of: "Exploration of Quartz, Feldspar, and Mica Minerals Using Geophysical Resistivity, Self-Potential, and Natural Electrical Field Techniques"
The paper presents interesting findings; however, I believe there are several areas that could benefit from further improvement to enhance its overall quality and impact. Firstly, I recommend a more thorough development of each section, with particu...
- 6 March 2024
- Published by Elsevier in Geothermics
- Vol. 119
Deciphering the Way Ratai geothermal system, Lampung, Indonesia: A comprehensive geochemical and isotopic analysis
- 6 March 2024
- Published by Elsevier in Geothermics
- Vol. 119
Deciphering the Way Ratai geothermal system, Lampung, Indonesia: A comprehensive geochemical and isotopic analysis
- 31 March 2023
- Published by Penerbit UMT, Universiti Malaysia Terengganu in Journal of Sustainability Science and Management
- Vol. 18 (3) , 147-154
MICROPLASTIC ABUNDANCE IN EDIBLE CRABS AND GASTROPODS ON THE BLANAKAN COAST
- 31 March 2023
- Published by Penerbit UMT, Universiti Malaysia Terengganu in Journal of Sustainability Science and Management
- Vol. 18 (3) , 147-154
MICROPLASTIC ABUNDANCE IN EDIBLE CRABS AND GASTROPODS ON THE BLANAKAN COAST
- Open Access
- 1 January 2022
- Published by The Institute for Research and Community Services (LPPM) ITB in Journal of Engineering and Technological Sciences
- Vol. 54 (4) , 220406
Geothermal System in Parang Wedang, Yogyakarta, Indonesia
Geothermal manifestations in Parangtritis, Indonesia, known as Parang Wedang Hot Spring, indicate a geothermal system in the subsurface. This circumstance motivated our research to model the Parang Wedang geothermal system in order to determine its subsurface conditions. Geological mapping, the geophysical method, and geochemical analysis were integrated to produce a conceptual model of the Parang Wedang geothermal system. The study area consists of structural hills, karst hills, and eolian plains with andesite breccias, limestone, andesite, and sand deposits as lithological variations. The results of magnetic modeling indicate that the research area is associated with the presence of an andesite intrusion and shows a NE-SW trending geological structure that is thought to be a path for hydrothermal fluid to the surface. Geochemical analysis was performed at two hot springs with temperatures of 47 degrees C and 49 degrees C. Geothermometer calculation showed that the geothermal reservoir in Parang Wedang has a temperature of 100 to 120 degrees C, a depth of about 180 to 285 m, and can be classified as a low enthalpy geothermal system.
- 1 January 2022
- Published by The Institute for Research and Community Services (LPPM) ITB in Journal of Engineering and Technological Sciences
- Vol. 54 (4) , 220406
Open AccessGeothermal System in Parang Wedang, Yogyakarta, Indonesia
Geothermal manifestations in Parangtritis, Indonesia, known as Parang Wedang Hot Spring, indicate a geothermal system in the subsurface. This circumstance motivated our research to model the Parang Wedang geothermal system in order to determine its subsurface conditions. Geological mapping, the geophysical method, and geochemical analysis were integrated to produce a conceptual model of the Parang Wedang geothermal system. The study area consists of structural hills, karst hills, and eolian plains with andesite breccias, limestone, andesite, and sand deposits as lithological variations. The results of magnetic modeling indicate that the research area is associated with the presence of an andesite intrusion and shows a NE-SW trending geological structure that is thought to be a path for hydrothermal fluid to the surface. Geochemical analysis was performed at two hot springs with temperatures of 47 degrees C and 49 degrees C. Geothermometer calculation showed that the geothermal reservoir in Parang Wedang has a temperature of 100 to 120 degrees C, a depth of about 180 to 285 m, and can be classified as a low enthalpy geothermal system.
- Open Access
- 1 November 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 882 (1) , 012034
The effect of coal stockpile on shallow groundwater aquifer: Study case Tarahan
This paper aims to determine the existence of groundwater contamination due to coal stockpile activity in shallow groundwater. The research area is located in a stockpile that has been operating since 1986. We conducted chemical content analysis at several points around the coal stockpile and outside the stockpile area to see the impact of pollution on the surrounding residents’ areas. This study also uses geoelectric methods and direct observations to identify shallow groundwater levels (water table). The research area has a groundwater depth of about 2 m from the surface, and groundwater flows from northeast to southwest (sea). The chemical content analysis results show that each sample taken around the stockpile is below the water quality standard threshold, so it can be concluded that coal stockpile activity does not contaminate the shallow groundwater. However, there is nitrate contamination from shallow groundwater located outside the stockpile area taken from dug wells and drilling wells with a depth of 8 m shows a value of 14.08-23.67 ppm (>10 ppm threshold). We suspect that this pollution is caused by the large number of mining activities carried out in the north of the study area.
- 1 November 2021
- Published by IOP Publishing in IOP Conference Series: Earth and Environmental Science
- Vol. 882 (1) , 012034
Open AccessThe effect of coal stockpile on shallow groundwater aquifer: Study case Tarahan
This paper aims to determine the existence of groundwater contamination due to coal stockpile activity in shallow groundwater. The research area is located in a stockpile that has been operating since 1986. We conducted chemical content analysis at several points around the coal stockpile and outside the stockpile area to see the impact of pollution on the surrounding residents’ areas. This study also uses geoelectric methods and direct observations to identify shallow groundwater levels (water table). The research area has a groundwater depth of about 2 m from the surface, and groundwater flows from northeast to southwest (sea). The chemical content analysis results show that each sample taken around the stockpile is below the water quality standard threshold, so it can be concluded that coal stockpile activity does not contaminate the shallow groundwater. However, there is nitrate contamination from shallow groundwater located outside the stockpile area taken from dug wells and drilling wells with a depth of 8 m shows a value of 14.08-23.67 ppm (>10 ppm threshold). We suspect that this pollution is caused by the large number of mining activities carried out in the north of the study area.