Guosheng Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Guosheng Liu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Guorui Wu
Changsha University of Science and Technology, Changsha, CHINA
4 shared publications - Yixiang Xia
Changsha University of Science and Technology, Changsha, CHINA
4 shared publications - Zewen Li
School of Electrical and Automation Engineering, East China Jiaotong University, Nanchang, China
3 shared publications - Chenguang Hu
Guangdong Power Grid Company Ltd., Zhaoqing Power Supply Bureau, Zhaoqing, China
1 shared publication - Feng
Changsha University of Science and Technology, Changsha, CHINA
1 shared publication - Ke Li
Guiyang Power Supply Bureau of Guizhou Power Grid Company Ltd., Guiyang, China
1 shared publication
Latest Publications
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
A Hybrid Transmission Network Traveling Wave Location Method Based on Fault Deduction and Wave Speed Optimization
Addressing the challenges brought by complex hybrid ring networks in fault section location and accurate location, this paper proposes a hybrid transmission network traveling wave (TW) location method based on fault deduction and wave speed optimization. First, the paper analyzes the TW propagation process and establishes equivalent models for each stage of the propagation process, deriving initial TW relationships between measurement points. Based on this, the fault deduction algorithm determines the TW propagation paths, enabling network decomposition of complex hybrid ring lines. Combining the concept of virtual fault (VF), a fault section location model is established, and the fault section is determined by maximizing the similarity of VF waveforms. Utilizing the TW arrival time in non-fault areas after network decomposition, a TW speed optimization model is established to obtain the optimal TW speed solution for the region, achieving accurate location. Verified by the PSCAD simulation platform, this method can accurately locate the fault section and determine the optimal TW speed in complex hybrid ring network scenarios, achieving accurate fault location.
- 10 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-11
A Hybrid Transmission Network Traveling Wave Location Method Based on Fault Deduction and Wave Speed Optimization
Addressing the challenges brought by complex hybrid ring networks in fault section location and accurate location, this paper proposes a hybrid transmission network traveling wave (TW) location method based on fault deduction and wave speed optimization. First, the paper analyzes the TW propagation process and establishes equivalent models for each stage of the propagation process, deriving initial TW relationships between measurement points. Based on this, the fault deduction algorithm determines the TW propagation paths, enabling network decomposition of complex hybrid ring lines. Combining the concept of virtual fault (VF), a fault section location model is established, and the fault section is determined by maximizing the similarity of VF waveforms. Utilizing the TW arrival time in non-fault areas after network decomposition, a TW speed optimization model is established to obtain the optimal TW speed solution for the region, achieving accurate location. Verified by the PSCAD simulation platform, this method can accurately locate the fault section and determine the optimal TW speed in complex hybrid ring network scenarios, achieving accurate fault location.
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (8) , 5866-5876
Traveling Wave Network Location Method Based on Virtual Fault Time Difference Information
To address the issues of location accuracy in traveling wave (TW) network location methods, which are susceptible to clock synchronization errors and TW speed inaccuracies. We propose a TW network location method based on virtual fault time difference information, simulating the propagation of TWs using virtual faults (VFs). Theoretically, the study analyzes the impact of transition resistance and TW heads (TWHs) aliasing on TWHs calibration, proposing an optimal effective time difference criterion that is unaffected by these factors. Algorithmically, VFs are first set in the faulty line, and a path search algorithm is used to obtain all TWH paths from the VF point to the measurement points. Subsequently, based on the optimal effective time difference selection criteria for different fault areas, steps such as filtering VF wave head paths and simulating virtual fault TWHs yield the optimal time difference matrix for the VFs. The accuracy of the VF location is assessed by calculating the degree of difference between the time difference information of virtual and real faults. An optimization algorithm continuously adjusts the VF point location and TW speed, gradually converging the VF point to the real fault point until they coincide, at which point the VF location corresponds to the real fault location. Verified by the PSCAD simulation platform, the proposed method can achieve precise fault location under various fault types, transition resistances, and noise interferences.
- 13 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 21 (8) , 5866-5876
Traveling Wave Network Location Method Based on Virtual Fault Time Difference Information
To address the issues of location accuracy in traveling wave (TW) network location methods, which are susceptible to clock synchronization errors and TW speed inaccuracies. We propose a TW network location method based on virtual fault time difference information, simulating the propagation of TWs using virtual faults (VFs). Theoretically, the study analyzes the impact of transition resistance and TW heads (TWHs) aliasing on TWHs calibration, proposing an optimal effective time difference criterion that is unaffected by these factors. Algorithmically, VFs are first set in the faulty line, and a path search algorithm is used to obtain all TWH paths from the VF point to the measurement points. Subsequently, based on the optimal effective time difference selection criteria for different fault areas, steps such as filtering VF wave head paths and simulating virtual fault TWHs yield the optimal time difference matrix for the VFs. The accuracy of the VF location is assessed by calculating the degree of difference between the time difference information of virtual and real faults. An optimization algorithm continuously adjusts the VF point location and TW speed, gradually converging the VF point to the real fault point until they coincide, at which point the VF location corresponds to the real fault location. Verified by the PSCAD simulation platform, the proposed method can achieve precise fault location under various fault types, transition resistances, and noise interferences.
- 7 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (3) , 3446-3455
Distribution Network Fault Location Method Based on Wide Scale Time Window Difference Operator
This study aims to address the challenge of fault location in distribution networks with closed-loop structures. We propose a comprehensive method that focuses on two aspects: traveling wave head calibration and fault location. By analyzing the propagation properties of hybrid lines traveling waves, we demonstrate the feasibility of optimizing wave speed using time difference measurements. To solve the time calibration problem of weak fault signals, we utilize the signal cumulative deviation curve to select the time window of fault mutation, and then develop a novel wide scale time window difference operator for accurate calibration. Finally, we use a positioning method based on dynamic virtual faults to optimize wave speed and accurately locate faults in both overhead and cable lines. We build an improved IEEE 118 node network using power system simulation software (PSCAD) for simulation verification, which shows that our proposed method can accurately calibrate the initial wavefront time of fault traveling waves and precisely locate the fault positions.
- 7 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (3) , 3446-3455
Distribution Network Fault Location Method Based on Wide Scale Time Window Difference Operator
This study aims to address the challenge of fault location in distribution networks with closed-loop structures. We propose a comprehensive method that focuses on two aspects: traveling wave head calibration and fault location. By analyzing the propagation properties of hybrid lines traveling waves, we demonstrate the feasibility of optimizing wave speed using time difference measurements. To solve the time calibration problem of weak fault signals, we utilize the signal cumulative deviation curve to select the time window of fault mutation, and then develop a novel wide scale time window difference operator for accurate calibration. Finally, we use a positioning method based on dynamic virtual faults to optimize wave speed and accurately locate faults in both overhead and cable lines. We build an improved IEEE 118 node network using power system simulation software (PSCAD) for simulation verification, which shows that our proposed method can accurately calibrate the initial wavefront time of fault traveling waves and precisely locate the fault positions.