Matthew Skalak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Matthew Skalak has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Benben
Detroit Medical Center, Detroit, MI, USA
2 shared publications Mazen Abdelhady
Detroit Medical Center, Detroit, MI, USA
2 shared publicationsAli Baydoun
Detroit Medical Center, Detroit, MI, USA
1 shared publication- Barrett G. Anderson
Detroit Medical Center Urology Residency, Harper Professional Building, 4160 John R St., Suite 1017, Detroit, MI 48201, USA
1 shared publication - Brandi D. Miller
Detroit Medical Center Urology Residency, Harper Professional Building, 4160 John R St., Suite 1017, Detroit, MI 48201, USA
1 shared publication Briana Kaplunov
1 shared publication
Latest Publications
- Open Access
- 9 September 2026
- Published by Elsevier in Urology Case Reports
- Vol. 69
Double-J stent traversing the inferior vena cava into the right atrium: a rare cause of bacteremia after chronic stent retention
- 9 September 2026
- Published by Elsevier in Urology Case Reports
- Vol. 69
Open AccessDouble-J stent traversing the inferior vena cava into the right atrium: a rare cause of bacteremia after chronic stent retention
- Open Access
- 20 April 2024
- Published by Hindawi Limited in Case Reports in Urology
- Vol. 2024, 1-3
The Management of Inflatable Penile Prosthesis Erosion and Infection following Iatrogenic Aspiration
This case report presents a unique and previously unreported case of malfunction, infection, and erosion of an inflatable penile prosthesis (IPP) resulting from iatrogenic injury during a priapism aspiration procedure performed by an emergency medicine physician. The patient, a 75-year-old male with a history of IPP placement for erectile dysfunction, presented with urinary retention and priapism, leading to inadvertent deflation of the IPP during aspiration. Subsequent evaluation revealed a pinhole opening on the scrotum, indicating infection and erosion of the prosthesis tubing. The patient underwent emergent explantation of the infected IPP, washout, cystoscopy, and insertion of a suprapubic tube. Intraoperative cultures identified Escherichia cloacae as the causative pathogen. This case highlights the importance of thorough chart review to identify patients with IPPs before aspiration procedures and emphasizes the need for healthcare provider education regarding potential complications in this patient population. Early recognition and management of such complications are crucial for optimal patient outcomes. While IPP placement remains a highly satisfactory treatment for erectile dysfunction, this case highlights the importance of vigilance to ensure the best care for patients with penile prostheses. It is noteworthy that ultimately, a new IPP was not placed in this patient due to the patients significant medical comorbidities.
- 20 April 2024
- Published by Hindawi Limited in Case Reports in Urology
- Vol. 2024, 1-3
Open AccessThe Management of Inflatable Penile Prosthesis Erosion and Infection following Iatrogenic Aspiration
This case report presents a unique and previously unreported case of malfunction, infection, and erosion of an inflatable penile prosthesis (IPP) resulting from iatrogenic injury during a priapism aspiration procedure performed by an emergency medicine physician. The patient, a 75-year-old male with a history of IPP placement for erectile dysfunction, presented with urinary retention and priapism, leading to inadvertent deflation of the IPP during aspiration. Subsequent evaluation revealed a pinhole opening on the scrotum, indicating infection and erosion of the prosthesis tubing. The patient underwent emergent explantation of the infected IPP, washout, cystoscopy, and insertion of a suprapubic tube. Intraoperative cultures identified Escherichia cloacae as the causative pathogen. This case highlights the importance of thorough chart review to identify patients with IPPs before aspiration procedures and emphasizes the need for healthcare provider education regarding potential complications in this patient population. Early recognition and management of such complications are crucial for optimal patient outcomes. While IPP placement remains a highly satisfactory treatment for erectile dysfunction, this case highlights the importance of vigilance to ensure the best care for patients with penile prostheses. It is noteworthy that ultimately, a new IPP was not placed in this patient due to the patients significant medical comorbidities.
- Open Access
- 1 January 2024
- Published by Wiley in Case Reports in Urology
- Vol. 2024 (1) , 4446878
Twisting of Inflatable Penile Prosthesis Tubing Leading to Device Malfunction and Required Explantation: A Rare Complication
Erectile dysfunction (ED), the impairment of achieving and maintaining an erection for satisfactory sexual intercourse, is a common pathology that men experience for a variety of different factors. Conservative treatment for ED includes changing medications, lifestyle modifications, and psychotherapy. Pharmaceutical and nonsurgical interventions include phosphodiesterase‐5 inhibitors(PDE‐5i), intracavernosal medication injections, and vacuum devices. Surgical treatment options for ED have evolved over time and currently include the use of inflatable penile prosthesis (IPP) and malleable penile prosthesis. IPP insertion is usually met with good patient satisfaction. However, complications of device insertion can include corporal perforation, urethral injury, cylinder erosion or extrusion, infection, and mechanical failure, to name a few. Our patient presented with device malfunction and intraoperative assessment showed the IPP tubing twisted at the levels of the reservoir on the first operation and the level of the cylinder and scrotal pump on the second operation. The twisting of the tubing resulted in a nonfunctioning IPP as the fluid was unable to fill the cylinders resulting in an erection. The patient was managed with complete device explanation and reinsertion of a new three‐piece IPP per the patient and partner’s request. This is the first case report highlighting this specific complication, and we hope to provide clinicians with the resources to recognize this rare complication.
- 1 January 2024
- Published by Wiley in Case Reports in Urology
- Vol. 2024 (1) , 4446878
Open AccessTwisting of Inflatable Penile Prosthesis Tubing Leading to Device Malfunction and Required Explantation: A Rare Complication
Erectile dysfunction (ED), the impairment of achieving and maintaining an erection for satisfactory sexual intercourse, is a common pathology that men experience for a variety of different factors. Conservative treatment for ED includes changing medications, lifestyle modifications, and psychotherapy. Pharmaceutical and nonsurgical interventions include phosphodiesterase‐5 inhibitors(PDE‐5i), intracavernosal medication injections, and vacuum devices. Surgical treatment options for ED have evolved over time and currently include the use of inflatable penile prosthesis (IPP) and malleable penile prosthesis. IPP insertion is usually met with good patient satisfaction. However, complications of device insertion can include corporal perforation, urethral injury, cylinder erosion or extrusion, infection, and mechanical failure, to name a few. Our patient presented with device malfunction and intraoperative assessment showed the IPP tubing twisted at the levels of the reservoir on the first operation and the level of the cylinder and scrotal pump on the second operation. The twisting of the tubing resulted in a nonfunctioning IPP as the fluid was unable to fill the cylinders resulting in an erection. The patient was managed with complete device explanation and reinsertion of a new three‐piece IPP per the patient and partner’s request. This is the first case report highlighting this specific complication, and we hope to provide clinicians with the resources to recognize this rare complication.
- Open Access
- 7 September 2023
- Published by Hindawi Limited in Case Reports in Urology
- Vol. 2023, 1-4
Robot-Assisted Repair of Bladder Rupture following Penile Ring Entrapment
Penile rings have been used to help sustain erection and enhance sexual pleasure for centuries. Constriction of the penis reduces the outflow of blood from the cavernosal tissue. However, if left for an extended time period, a condition called penile ring entrapment can occur. This may result in severe edema, gangrene, necrosis, and even penile amputation. Penile ring entrapment is a very rare condition; complete urinary obstruction with concomitant bladder rupture as a result renders this case even more extraordinary. We discuss our experience in the management of a 64-year-old man, who presented with altered mental status and inability to urinate, found to have penile ring entrapment and intraperitoneal bladder rupture. Removal of the constricting ring was performed in the ED, and bladder injury and penile necrosis were subsequently repaired with robot-assisted laparoscopic cystorrhaphy, penectomy, and perineal urethrostomy.
- 7 September 2023
- Published by Hindawi Limited in Case Reports in Urology
- Vol. 2023, 1-4
Open AccessRobot-Assisted Repair of Bladder Rupture following Penile Ring Entrapment
Penile rings have been used to help sustain erection and enhance sexual pleasure for centuries. Constriction of the penis reduces the outflow of blood from the cavernosal tissue. However, if left for an extended time period, a condition called penile ring entrapment can occur. This may result in severe edema, gangrene, necrosis, and even penile amputation. Penile ring entrapment is a very rare condition; complete urinary obstruction with concomitant bladder rupture as a result renders this case even more extraordinary. We discuss our experience in the management of a 64-year-old man, who presented with altered mental status and inability to urinate, found to have penile ring entrapment and intraperitoneal bladder rupture. Removal of the constricting ring was performed in the ED, and bladder injury and penile necrosis were subsequently repaired with robot-assisted laparoscopic cystorrhaphy, penectomy, and perineal urethrostomy.