Nathan M. Boyle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Nathan M. Boyle has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Rusi P. Taleyarkhan
School of Nuclear Engineering, Purdue University, West Lafayette, USA
4 shared publications Brian Archambault
Sagamore Adams Laboratories, 190 S. LaSalle St., Suite 3700, Chicago, Illinois 60603
1 shared publication- Brian C. Archambault
Archambault Consulting, 3601 Sagamore Pkwy N, Lafayette, IN 47904
1 shared publication - Catalin Harabagiu
School of Nuclear Engineering, Purdue University , West Lafayette, IN 47906
1 shared publication Mitch Hemesath
School of Nuclear Engineering, Purdue University, W. Lafayette, Indiana 47907 ()
1 shared publication- Mitchell P Hemesath
School of Nuclear Engineering, Purdue University, West Lafayette, IN 47907
1 shared publication
Latest Publications
- 15 September 2023
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 9 (4) , 1-23
9 MV LINAC Photoneutron Interrogation of Uranium With Advanced Acoustically Tensioned Metastable Fluid Detectors
Active special nuclear material (SNM) photoneutron interrogation research with Acoustically Tensioned Metastable Fluid Detector (ATMFD) sensor technology is discussed which provides evidence for enabling real time detection of special nuclear material (SNM) even when deployed under extreme 15,000 R h-1 (9 MeV endpoint) X-ray beams. Experiments to detect 3.2 kg DU are described with use of two designs of the economical E-ATMFD, viz., E-ATMFD.Ver.0 and E-ATMFD.Ver.1, respectively, at standoffs ranging from 0.1 m to 10 m - including with the E-ATMFD directly within the interrogating beam. Under similar conditions and with 100% photon rejection (i.e., 0 cpm with beam on, and w/o SNM), the E-ATMFD.Ver.1 design was shown capable of ~6x (600%) higher gain at ~10x lower drive powers over E-ATMFD.Ver.0 (with beam on and with SNM). The sensitivity gain rises to ~27x (i.e., 2,700%) with the E-ATMFD.Ver.1 operating at 0.99 W and a background count rate of ~1 cpm. The E-ATMFD.Ver.1 demonstrated 100% photon blindness (0 cpm) while operating at ~0.56 W drive power and placed directly within the beam under 15,000 R/h; including the SNM target led to a count rate of up to 50 cpm - revealing the E-ATMFD.Ver.1 as potentially field-capable for detecting U-based SNMs within seconds from photofission neutron signals, even when deployed directly within the interrogating photon beam.
- 15 September 2023
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 9 (4) , 1-23
9 MV LINAC Photoneutron Interrogation of Uranium With Advanced Acoustically Tensioned Metastable Fluid Detectors
Active special nuclear material (SNM) photoneutron interrogation research with Acoustically Tensioned Metastable Fluid Detector (ATMFD) sensor technology is discussed which provides evidence for enabling real time detection of special nuclear material (SNM) even when deployed under extreme 15,000 R h-1 (9 MeV endpoint) X-ray beams. Experiments to detect 3.2 kg DU are described with use of two designs of the economical E-ATMFD, viz., E-ATMFD.Ver.0 and E-ATMFD.Ver.1, respectively, at standoffs ranging from 0.1 m to 10 m - including with the E-ATMFD directly within the interrogating beam. Under similar conditions and with 100% photon rejection (i.e., 0 cpm with beam on, and w/o SNM), the E-ATMFD.Ver.1 design was shown capable of ~6x (600%) higher gain at ~10x lower drive powers over E-ATMFD.Ver.0 (with beam on and with SNM). The sensitivity gain rises to ~27x (i.e., 2,700%) with the E-ATMFD.Ver.1 operating at 0.99 W and a background count rate of ~1 cpm. The E-ATMFD.Ver.1 demonstrated 100% photon blindness (0 cpm) while operating at ~0.56 W drive power and placed directly within the beam under 15,000 R/h; including the SNM target led to a count rate of up to 50 cpm - revealing the E-ATMFD.Ver.1 as potentially field-capable for detecting U-based SNMs within seconds from photofission neutron signals, even when deployed directly within the interrogating photon beam.
- Open Access
- 12 September 2023
- Published by MDPI AG in Instruments
- Vol. 7 (3) , 26
A Novel, Rapid Response Renewable Biopolymer Neutron and Gamma Radiation Solid-State Detector for Dosimetry and Nuclear Reactor Flux-Power Mapping
A novel solid-state neutron and gamma radiation monitor-dosimeter based on biopolymer polylactic acid (PLA) is presented. The resulting detector (PLAD) technology takes advantage of property changes of the renewable PLA resin when subject to ionizing nuclear radiation. A simple yet rapid and accurate (±10%) low-cost (<$0.01/detector) mass loss upon dissolution (MLD) technique was successfully developed; MLD is based on a simple mass balance for discerning neutron and/or gamma doses using small (40 mg, ~4 mm diameter) ultra-low-cost (<$0.01) resin beads via dissolution in acetone. The GammaCellTM Co-60 irradiator, and the PUR-1 12 kW fission nuclear research reactor were utilized, respectively. Irradiation absorbed doses ranged from 1 to 100 kGy. Acetone bath temperature was varied from ~40 °C to ~54 °C. Results revealed a strong dependence of MLD on acetone bath temperature between neutron and gamma photon dose components; this allowed for the unique ability of PLAD to potentially perform as both a neutron-cum-gamma or as a gamma or neutron radiation dosimeter and intensity level detector. A linear trend is found for combined neutron and gamma radiation doses from 0 to 40 kGy when dissolution is conducted above 50 °C. The important potential ability to distinguish neutron from gamma radiation fields was scoped and found to be feasible by determining MLD at 45 °C. The potential was studied for simultaneous use as an in-core neutron and gamma monitor of an operating 3 GWt light-water reactor (LWR). Scoping tests were conducted with the pre-irradiated (@ 20 °C) PLAD resin beads followed by heating to in-core LWR coolant (300 °C) conditions for ~30 s corresponding to the time to reach ~40 kGy total doses in a typical 3 GWt LWR. MLD results were unaffected, indicating the exciting and unique potential for in situ (low-cost, accurate and rapid) simultaneous mapping of neutron and gamma radiation fluxes, related dosimetry, and fission power level monitoring.
- 12 September 2023
- Published by MDPI AG in Instruments
- Vol. 7 (3) , 26
Open AccessA Novel, Rapid Response Renewable Biopolymer Neutron and Gamma Radiation Solid-State Detector for Dosimetry and Nuclear Reactor Flux-Power Mapping
A novel solid-state neutron and gamma radiation monitor-dosimeter based on biopolymer polylactic acid (PLA) is presented. The resulting detector (PLAD) technology takes advantage of property changes of the renewable PLA resin when subject to ionizing nuclear radiation. A simple yet rapid and accurate (±10%) low-cost (<$0.01/detector) mass loss upon dissolution (MLD) technique was successfully developed; MLD is based on a simple mass balance for discerning neutron and/or gamma doses using small (40 mg, ~4 mm diameter) ultra-low-cost (<$0.01) resin beads via dissolution in acetone. The GammaCellTM Co-60 irradiator, and the PUR-1 12 kW fission nuclear research reactor were utilized, respectively. Irradiation absorbed doses ranged from 1 to 100 kGy. Acetone bath temperature was varied from ~40 °C to ~54 °C. Results revealed a strong dependence of MLD on acetone bath temperature between neutron and gamma photon dose components; this allowed for the unique ability of PLAD to potentially perform as both a neutron-cum-gamma or as a gamma or neutron radiation dosimeter and intensity level detector. A linear trend is found for combined neutron and gamma radiation doses from 0 to 40 kGy when dissolution is conducted above 50 °C. The important potential ability to distinguish neutron from gamma radiation fields was scoped and found to be feasible by determining MLD at 45 °C. The potential was studied for simultaneous use as an in-core neutron and gamma monitor of an operating 3 GWt light-water reactor (LWR). Scoping tests were conducted with the pre-irradiated (@ 20 °C) PLAD resin beads followed by heating to in-core LWR coolant (300 °C) conditions for ~30 s corresponding to the time to reach ~40 kGy total doses in a typical 3 GWt LWR. MLD results were unaffected, indicating the exciting and unique potential for in situ (low-cost, accurate and rapid) simultaneous mapping of neutron and gamma radiation fluxes, related dosimetry, and fission power level monitoring.
- 3 June 2020
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 6 (4)
Tensioned Metastable Fluid Detectors for Spectrometric Radon–Progeny Detection and AARST-NRPP Standard Qualification
This paper describes how the tensioned metastable fluid detector (TMFD) sensor technology was successfully configured and qualified for efficient, accurate, spectroscopic, and cost-effective radon and progeny spectroscopic detection alongside meeting/exceeding the standards set by the American Association of Radon Scientists and Technologists-National Radon Proficiency Program (AARST-NRPP) Device Evaluation Program (DEP). The DEP represents addressing of a challenging test matrix that assesses a radon collection and measurement device's performance over a variety of functional parameters and environmental conditions. Qualification test conditions covered in this study included performance vetting of the centrifugally tensioned metastable fluid detector (CTMFD) technology under a wide range of temperatures, noncondensing relative humidity (RH) levels, condensing conditions, atmospheric pressures, background photon radiation, nonionizing external electromagnetic (EM) fields, shock and vibration, and air movement. Of all these parameters, only the ambient temperature played a first-order role on radon collection; for this reason, a dynamic compensation algorithm was developed and successfully validated. The remaining AARST-NRPP test parameters were found to have negligible affects. In comparison to state-of-art radon detector systems, the resulting radon specific CTMFD (R-CTMFD) sensor system and protocol are shown to provide for superior sensitivity along with spectroscopic identification of radon–progeny alpha emitters while remaining 100% blind to interfering gamma–beta background radiation.
- 3 June 2020
- Published by ASME International in Journal of Nuclear Engineering and Radiation Science
- Vol. 6 (4)
Tensioned Metastable Fluid Detectors for Spectrometric Radon–Progeny Detection and AARST-NRPP Standard Qualification
This paper describes how the tensioned metastable fluid detector (TMFD) sensor technology was successfully configured and qualified for efficient, accurate, spectroscopic, and cost-effective radon and progeny spectroscopic detection alongside meeting/exceeding the standards set by the American Association of Radon Scientists and Technologists-National Radon Proficiency Program (AARST-NRPP) Device Evaluation Program (DEP). The DEP represents addressing of a challenging test matrix that assesses a radon collection and measurement device's performance over a variety of functional parameters and environmental conditions. Qualification test conditions covered in this study included performance vetting of the centrifugally tensioned metastable fluid detector (CTMFD) technology under a wide range of temperatures, noncondensing relative humidity (RH) levels, condensing conditions, atmospheric pressures, background photon radiation, nonionizing external electromagnetic (EM) fields, shock and vibration, and air movement. Of all these parameters, only the ambient temperature played a first-order role on radon collection; for this reason, a dynamic compensation algorithm was developed and successfully validated. The remaining AARST-NRPP test parameters were found to have negligible affects. In comparison to state-of-art radon detector systems, the resulting radon specific CTMFD (R-CTMFD) sensor system and protocol are shown to provide for superior sensitivity along with spectroscopic identification of radon–progeny alpha emitters while remaining 100% blind to interfering gamma–beta background radiation.
- 17 May 2019
- Published by Wolters Kluwer Health in Health Physics
- Vol. 117 (4) , 434-442
Radon and Progeny Detection Using Tensioned Metastable Fluid Detectors
Radon and other alpha-emitting nuclides in air can be a significant risk for health hazards in the workplace and in dwellings. Radon gas in US homes causes over 21,000 deaths from lung cancer annually, according to the US Environmental Protection Agency (US EPA). Alpha-emitting radionuclides from airborne contamination in the nuclear industry also constitute a known safety and security-safeguards related issue. Purdue University, along with Sagamore Adams Laboratories LLC, have developed the tensioned metastable fluid detector (TMFD) sensor technology for general-purpose alpha-neutron-fission. For radon detection, radon gas in air is sparged through the TMFD detection fluid, after which this radon-bearing fluid is placed into a tensioned metastable state. In this metastable state, an audible-visible cavitation (alpha radiation) detection event is created and electronically recorded. Tailoring the level of tension enables spectroscopic information through energy discrimination of radon and its progeny; This is also applicable to other alpha emitting isotopes (Pu, Cm, U…). TMFDs boast high intrinsic detection efficiencies (>95%) for alpha spectroscopy while remaining blind to background beta and gamma radiation even in ~103 R h−1 fields. The immunity to beta and gammas allows for reusability of the detection fluid through immunity to beta buildup from thoron and radon progeny. TMFD technology was used to measure the concentration of radon and radon progeny in air for concentrations from 74 Bq m−3 to 740 Bq m−3. The system measures radon concentration between these levels within 24 h with an intrinsic relative error (IRE) of ± 15% according to the standards set forth by the American Association of Radon Scientists and Technicians-National Radon Proficiency Program (AARST-NRPP) Device Evaluation Program (DEP). Precision evaluation defined using the relative standard deviation set by the AARST-NRPP measured a deviation of <5%, which exceeds the requirement of <25%. Temperature effects from 10°C and 27°C were assessed and corrected for dynamically. A radon decay correction method was introduced to correct for the radon activity decrease in the detection fluid over the counting period due to the ~3.8 d half-life. Blind testing was also successfully performed* with standards from the Bowser-Morner Radon Reference laboratory (2018); within 6 h, the TMFD-based technology accurately measured the concentration of radon to within 20% of the reference standards. Non-condensing relative humidity levels up to 95% per AARST-NRPP were assessed for and were found to have no impact on radon detection. This work improves upon the previous work by splitting the calibration curve into two distinct regions and adds additional information pertaining to the effects of relative humidity on the system.
- 17 May 2019
- Published by Wolters Kluwer Health in Health Physics
- Vol. 117 (4) , 434-442
Radon and Progeny Detection Using Tensioned Metastable Fluid Detectors
Radon and other alpha-emitting nuclides in air can be a significant risk for health hazards in the workplace and in dwellings. Radon gas in US homes causes over 21,000 deaths from lung cancer annually, according to the US Environmental Protection Agency (US EPA). Alpha-emitting radionuclides from airborne contamination in the nuclear industry also constitute a known safety and security-safeguards related issue. Purdue University, along with Sagamore Adams Laboratories LLC, have developed the tensioned metastable fluid detector (TMFD) sensor technology for general-purpose alpha-neutron-fission. For radon detection, radon gas in air is sparged through the TMFD detection fluid, after which this radon-bearing fluid is placed into a tensioned metastable state. In this metastable state, an audible-visible cavitation (alpha radiation) detection event is created and electronically recorded. Tailoring the level of tension enables spectroscopic information through energy discrimination of radon and its progeny; This is also applicable to other alpha emitting isotopes (Pu, Cm, U…). TMFDs boast high intrinsic detection efficiencies (>95%) for alpha spectroscopy while remaining blind to background beta and gamma radiation even in ~103 R h−1 fields. The immunity to beta and gammas allows for reusability of the detection fluid through immunity to beta buildup from thoron and radon progeny. TMFD technology was used to measure the concentration of radon and radon progeny in air for concentrations from 74 Bq m−3 to 740 Bq m−3. The system measures radon concentration between these levels within 24 h with an intrinsic relative error (IRE) of ± 15% according to the standards set forth by the American Association of Radon Scientists and Technicians-National Radon Proficiency Program (AARST-NRPP) Device Evaluation Program (DEP). Precision evaluation defined using the relative standard deviation set by the AARST-NRPP measured a deviation of <5%, which exceeds the requirement of <25%. Temperature effects from 10°C and 27°C were assessed and corrected for dynamically. A radon decay correction method was introduced to correct for the radon activity decrease in the detection fluid over the counting period due to the ~3.8 d half-life. Blind testing was also successfully performed* with standards from the Bowser-Morner Radon Reference laboratory (2018); within 6 h, the TMFD-based technology accurately measured the concentration of radon to within 20% of the reference standards. Non-condensing relative humidity levels up to 95% per AARST-NRPP were assessed for and were found to have no impact on radon detection. This work improves upon the previous work by splitting the calibration curve into two distinct regions and adds additional information pertaining to the effects of relative humidity on the system.