DCDanni Chen

Danni Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Danni Chen has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Bo Zhu

    School of Materials Science and Engineering, Shanghai University, Shanghai 200444, China

    1 shared publication
  • Jun Wang

    School of Materials Science and Engineering, Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai 200444, China

    1 shared publication
  • Shouyan Zhang

    School of Materials Science and Engineering, Shanghai Engineering Research Center of Organ Repair, Shanghai University, Shanghai 200444, China

    1 shared publication
  • Shuhua Zhang

    School of Materials Science and Engineering, Shanghai University, 99 Shangda Road, Baoshan, Shanghai 200444, China

    1 shared publication
  • Sihao Qian

    State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China

    1 shared publication
  • Wei Wu

    School of Materials Science and Engineering, Shanghai University, 99 Shangda Road, Baoshan, Shanghai 200444, China

    1 shared publication

Latest Publications

  • Open Access

    Phosphorylcholine-Functionalized PEDOT-Gated Organic Electrochemical Transistor Devices for Ultra-Specific and Sensitive C-Reactive Protein Detection

    by Sihao Qian, Shouyan Zhang, Danni Chen, Jun Wang, Wei Wu, Shuhua Zhang, Zhi Geng, Yong He, Bo Zhu

    Affinity-based organic electrochemical transistor (OECT) sensors offer an attractive approach to point-of-care diagnostics due to their extreme sensitivity and easy operation; however, their application in the real world is frequently challenged by the poor storage stability of antibody proteins and the interference from biofouling in complex biofluids. In this work, we developed an antibody-free and antifouling OECT biosensor to detect C-reactive protein (CRP) at ultra-high specificity and sensitivity. The key to this novel biosensor is the gate coated by phosphorylcholine-functionalized poly (3,4-ethylene dioxythiophene) (PEDOT-PC), which possesses large capacitance and low impedance, prevents biofouling of bovine serum albumin (BSA) and the fetal bovine serum (FBS), and interacts specifically with CRP molecules in the presence of calcium ions. This PEDOT-PC-gated OECT biosensor demonstrated exceptional sensitivity when detecting the CRP molecules at 10 pg/mL, while significantly depressing the signal from the nonspecific binding. This indicates that this biosensor could detect the CRP molecules directly without nonspecific binding blocking, the usual process for the earlier transistor sensors before detection. We envision that this PEDOT-PC-gated OECT biosensor platform may offer a potentially valuable tool for point-of-care diagnostics as it alleviates concerns about poor antibody stability and BSA blocking inconstancy.