Tobias Oberhoffner
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tobias Oberhoffner has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Angelika Dierker
MED-EL Medical Electronics, Austria
1 shared publicationAstrid Braun
Cecilienstift Halberstadt Cochlear-Implant-Rehabilitationszentrum
1 shared publicationDietmar Hecker
Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes Klinik für Hals-, Nasen- und Ohrenheilkunde
1 shared publicationGoetz Brademann
Klinik fr Hals-, Nasen-, Ohrenheilkunde, Kopf- und Halschirurgie; Phoniatrie und Pdaudiologie, Germany
1 shared publicationHeike Bagus
Bagus GmbH Cochlear Implant Centrum Ruhr
1 shared publicationMatthias Hey
Universitätsklinikum Schleswig-Holstein Campus Kiel Hals-, Nasen-, Ohrenheilkunde, Kopf- und Halschirurgie
1 shared publication
Latest Publications
- Open Access
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (2) , 650-659
Effects of Intraoperative Cochlear Implant Electrode Conditioning on Impedances and Electrically Evoked Compound Action Potentials
Objective: The current study investigates whether, during a Cochlear Implant (CI) surgery, conditioning (i.e. applying short bursts of electrical stimulation) within a saline solution can have positive effects on subsequent intra-operative measurements. We hypothesize that, based on previous research, the impedance values will be reduced, and that the reproducibility of Electrically Evoked Compound Action Potentials (ECAPs) is improved as a result of conditioning. Methods: We conditioned half of the electrode contacts, within a saline solution, before CI insertion, using 23 MED-EL implants. Impedance was measured for both the conditioned and non-conditioned groups at five time points. Repeated ECAP recordings were measured and compared between the conditioned and non-conditioned groups. Results: Impedance of the electrode contacts were reduced by 31% after conditioning in saline solution; however, there were no clinically relevant differences after the implantation of the electrode array. The hypothesis that measurement reproducibility would be increased after conditioning could not be confirmed with our data. Within the saline solution, we observed that 44% of the electrode contacts were covered with air bubbles, which most disappeared after implantation. However, these air bubbles limited the effectiveness of the conditioning within the saline solution. Lastly, the effect of conditioning on the reference electrode stimulation was approximately 16% of the total reduction in impedance. Conclusion: Our data does not suggest that intraoperative conditioning is clinically required for cochlear implantation with MED-EL implants. Additionally, an in-vivo ECAP recording can be considered as a method of conditioning the electrode contacts. Significance: We confirm that the common clinical practice does not need to be changed.
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (2) , 650-659
Open AccessEffects of Intraoperative Cochlear Implant Electrode Conditioning on Impedances and Electrically Evoked Compound Action Potentials
Objective: The current study investigates whether, during a Cochlear Implant (CI) surgery, conditioning (i.e. applying short bursts of electrical stimulation) within a saline solution can have positive effects on subsequent intra-operative measurements. We hypothesize that, based on previous research, the impedance values will be reduced, and that the reproducibility of Electrically Evoked Compound Action Potentials (ECAPs) is improved as a result of conditioning. Methods: We conditioned half of the electrode contacts, within a saline solution, before CI insertion, using 23 MED-EL implants. Impedance was measured for both the conditioned and non-conditioned groups at five time points. Repeated ECAP recordings were measured and compared between the conditioned and non-conditioned groups. Results: Impedance of the electrode contacts were reduced by 31% after conditioning in saline solution; however, there were no clinically relevant differences after the implantation of the electrode array. The hypothesis that measurement reproducibility would be increased after conditioning could not be confirmed with our data. Within the saline solution, we observed that 44% of the electrode contacts were covered with air bubbles, which most disappeared after implantation. However, these air bubbles limited the effectiveness of the conditioning within the saline solution. Lastly, the effect of conditioning on the reference electrode stimulation was approximately 16% of the total reduction in impedance. Conclusion: Our data does not suggest that intraoperative conditioning is clinically required for cochlear implantation with MED-EL implants. Additionally, an in-vivo ECAP recording can be considered as a method of conditioning the electrode contacts. Significance: We confirm that the common clinical practice does not need to be changed.
- 13 March 2018
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 97 (05) , 313-320
Multizentrische Analyse des Nutzerverhaltens von Cochlea-Implantat-Trägern
Zusammenfassung: Zusammenfassung Neuartige Cochlear-Implant-Sprachprozessoren bieten die Möglichkeit der Speicherung von Nutzungsdaten (Datalogging). Mit Hilfe dieser Informationen kann eine gezieltere individuelle Betreuung von Patienten ermöglicht werden. Allerdings fehlen bisher Normdaten in größerem Umfang zum individuellen Nutzungsverhalten. Material und Methoden Im Rahmen einer retrospektiven Studie wurden die Nutzungsdaten von 2687 Patienten ausgewertet. Alle Patienten waren mit dem Nucleus 6-System der Firma Cochlear Ltd. versorgt. Ergebnisse Die Daten ermöglichen für die Nutzungsdauer bzw. Tragedauern von Cochlear-Implant-Sprachprozessoren einen Normalbereich festzulegen. Ebenso ist die Identifikation von auffälligem Nutzungsverhalten möglich.
- 13 March 2018
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 97 (05) , 313-320
Multizentrische Analyse des Nutzerverhaltens von Cochlea-Implantat-Trägern
Zusammenfassung: Zusammenfassung Neuartige Cochlear-Implant-Sprachprozessoren bieten die Möglichkeit der Speicherung von Nutzungsdaten (Datalogging). Mit Hilfe dieser Informationen kann eine gezieltere individuelle Betreuung von Patienten ermöglicht werden. Allerdings fehlen bisher Normdaten in größerem Umfang zum individuellen Nutzungsverhalten. Material und Methoden Im Rahmen einer retrospektiven Studie wurden die Nutzungsdaten von 2687 Patienten ausgewertet. Alle Patienten waren mit dem Nucleus 6-System der Firma Cochlear Ltd. versorgt. Ergebnisse Die Daten ermöglichen für die Nutzungsdauer bzw. Tragedauern von Cochlear-Implant-Sprachprozessoren einen Normalbereich festzulegen. Ebenso ist die Identifikation von auffälligem Nutzungsverhalten möglich.