TOTobias Oberhoffner

Tobias Oberhoffner

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tobias Oberhoffner has a total of 15 co-authors. Here are the top co-authors by number of shared publications:

  • Angelika Dierker

    MED-EL Medical Electronics, Austria

    1 shared publication
  • Astrid Braun

    Cecilienstift Halberstadt Cochlear-Implant-Rehabilitationszentrum

    1 shared publication
  • Dietmar Hecker

    Universitätsklinikum des Saarlandes und Medizinische Fakultät der Universität des Saarlandes Klinik für Hals-, Nasen- und Ohrenheilkunde

    1 shared publication
  • Goetz Brademann

    Klinik fr Hals-, Nasen-, Ohrenheilkunde, Kopf- und Halschirurgie; Phoniatrie und Pdaudiologie, Germany

    1 shared publication
  • Heike Bagus

    Bagus GmbH Cochlear Implant Centrum Ruhr

    1 shared publication
  • Matthias Hey

    Universitätsklinikum Schleswig-Holstein Campus Kiel Hals-, Nasen-, Ohrenheilkunde, Kopf- und Halschirurgie

    1 shared publication

Latest Publications

  • Open Access

    Effects of Intraoperative Cochlear Implant Electrode Conditioning on Impedances and Electrically Evoked Compound Action Potentials

    by Tobias Oberhoffner, Robert Mlynski, Sebastian Schraven, Goetz Brademann, Angelika Dierker, Philipp Spitzer, Matthias Hey

    Objective: The current study investigates whether, during a Cochlear Implant (CI) surgery, conditioning (i.e. applying short bursts of electrical stimulation) within a saline solution can have positive effects on subsequent intra-operative measurements. We hypothesize that, based on previous research, the impedance values will be reduced, and that the reproducibility of Electrically Evoked Compound Action Potentials (ECAPs) is improved as a result of conditioning. Methods: We conditioned half of the electrode contacts, within a saline solution, before CI insertion, using 23 MED-EL implants. Impedance was measured for both the conditioned and non-conditioned groups at five time points. Repeated ECAP recordings were measured and compared between the conditioned and non-conditioned groups. Results: Impedance of the electrode contacts were reduced by 31% after conditioning in saline solution; however, there were no clinically relevant differences after the implantation of the electrode array. The hypothesis that measurement reproducibility would be increased after conditioning could not be confirmed with our data. Within the saline solution, we observed that 44% of the electrode contacts were covered with air bubbles, which most disappeared after implantation. However, these air bubbles limited the effectiveness of the conditioning within the saline solution. Lastly, the effect of conditioning on the reference electrode stimulation was approximately 16% of the total reduction in impedance. Conclusion: Our data does not suggest that intraoperative conditioning is clinically required for cochlear implantation with MED-EL implants. Additionally, an in-vivo ECAP recording can be considered as a method of conditioning the electrode contacts. Significance: We confirm that the common clinical practice does not need to be changed.


  • Multizentrische Analyse des Nutzerverhaltens von Cochlea-Implantat-Trägern

    by Tobias Oberhoffner, Ulrich Hoppe, Matthias Hey, Dietmar Hecker, Heike Bagus, Peter Voigt, Silvia Schicktanz, Astrid Braun, Thomas Hocke

    Zusammenfassung: Zusammenfassung Neuartige Cochlear-Implant-Sprachprozessoren bieten die Möglichkeit der Speicherung von Nutzungsdaten (Datalogging). Mit Hilfe dieser Informationen kann eine gezieltere individuelle Betreuung von Patienten ermöglicht werden. Allerdings fehlen bisher Normdaten in größerem Umfang zum individuellen Nutzungsverhalten. Material und Methoden Im Rahmen einer retrospektiven Studie wurden die Nutzungsdaten von 2687 Patienten ausgewertet. Alle Patienten waren mit dem Nucleus 6-System der Firma Cochlear Ltd. versorgt. Ergebnisse Die Daten ermöglichen für die Nutzungsdauer bzw. Tragedauern von Cochlear-Implant-Sprachprozessoren einen Normalbereich festzulegen. Ebenso ist die Identifikation von auffälligem Nutzungsverhalten möglich.