Huidong Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Huidong Wang has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jianhui Hu
Harbin Institute of Technology
7 shared publications - Yong Li
School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China
5 shared publications - Chun He
School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China
2 shared publications - Fangrui Wei
School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China
2 shared publications - Chuanyang Li
Laboratory of Intelligent Control, PLA Rocket Force University of Engineering, Xi’an, China
1 shared publication Feng Ren
Department of Geotechnical Engineering, College of Civil Engineering, Tongji University, Shanghai, 200092, China
1 shared publication
Latest Publications
- 20 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (5) , 4888-4899
Gain Compensation-Based Quasi-Resonant PLL With Adaptive Super-Twisting SMO for Position Error Suppression of IPMSM Sensorless Control
In this paper, a gain compensation-based quasi-resonant phase-locked loop (GCQR-PLL) with adaptive super-twisting sliding-mode observer (AST-SMO) is proposed. The conventional SMO typically employs a low-pass filter (LPF) and a quadrature phase-locked loop (QPLL) for position extraction. However, the tracking performance of the conventional QPLL is unsatisfactory, leading to position estimation error under transient conditions. Furthermore, the LPF fails to mitigate the DC disturbance caused by detection errors in the estimated backelectromotive force (EMF), resulting in position estimation error. To minimize the position estimation error, the proposed GCQR-PLL performs gain compensation under transient condition, which ensures sufficient bandwidth for position extraction, and at the same time, it effectively suppresses the DC disturbance due to detection error in estimated back-EMF by quasi-resonant (QR) structure. Additionally, the AST-SMO can diminish chattering at lower speeds while enhancing position estimation accuracy at higher speeds. The effectiveness of the proposed algorithm is verified under different operating conditions.
- 20 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (5) , 4888-4899
Gain Compensation-Based Quasi-Resonant PLL With Adaptive Super-Twisting SMO for Position Error Suppression of IPMSM Sensorless Control
In this paper, a gain compensation-based quasi-resonant phase-locked loop (GCQR-PLL) with adaptive super-twisting sliding-mode observer (AST-SMO) is proposed. The conventional SMO typically employs a low-pass filter (LPF) and a quadrature phase-locked loop (QPLL) for position extraction. However, the tracking performance of the conventional QPLL is unsatisfactory, leading to position estimation error under transient conditions. Furthermore, the LPF fails to mitigate the DC disturbance caused by detection errors in the estimated backelectromotive force (EMF), resulting in position estimation error. To minimize the position estimation error, the proposed GCQR-PLL performs gain compensation under transient condition, which ensures sufficient bandwidth for position extraction, and at the same time, it effectively suppresses the DC disturbance due to detection error in estimated back-EMF by quasi-resonant (QR) structure. Additionally, the AST-SMO can diminish chattering at lower speeds while enhancing position estimation accuracy at higher speeds. The effectiveness of the proposed algorithm is verified under different operating conditions.
- 31 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (2) , 2160-2164
Simplified Pre-Analysis of Fault Severity for Interturn Short-Circuit Faults in Fault-Tolerant Permanent Magnet Machines
This letter proposes a simplified offline preanalysis method of fault severity for interturn short-circuit faults (ISCFs) in fault-tolerant permanent magnet synchronous machines (FTPMSMs). For fault diagnosis and fault-tolerant (FT) control, it is important to predict how much short-circuit current will be generated at various speeds, loads, shorted turns ratios, and fault resistances. However, predicting the short-circuit current usually needs to solve differential equations by closed-loop simulation or finite element analysis (FEA). To increase the efficiency of fault preanalysis, the proposed method provides a simple solution to quickly offline predict the amplitude of short-circuit current. Simulation and experimental results show the effectiveness of the proposed method for different fault severities and various operations.
- 31 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (2) , 2160-2164
Simplified Pre-Analysis of Fault Severity for Interturn Short-Circuit Faults in Fault-Tolerant Permanent Magnet Machines
This letter proposes a simplified offline preanalysis method of fault severity for interturn short-circuit faults (ISCFs) in fault-tolerant permanent magnet synchronous machines (FTPMSMs). For fault diagnosis and fault-tolerant (FT) control, it is important to predict how much short-circuit current will be generated at various speeds, loads, shorted turns ratios, and fault resistances. However, predicting the short-circuit current usually needs to solve differential equations by closed-loop simulation or finite element analysis (FEA). To increase the efficiency of fault preanalysis, the proposed method provides a simple solution to quickly offline predict the amplitude of short-circuit current. Simulation and experimental results show the effectiveness of the proposed method for different fault severities and various operations.
- 25 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (4) , 8336-8345
Fault Phase Location for Interturn Short-Circuit Faults in Symmetrical Six-Phase PMSMs Based on Subspace Current Residual
Fault location can also be called fault isolation which is an important task of fault diagnosis. This paper proposes a fault location method for interturn short circuit faults (ISCF) in symmetrical six-phase permanent magnet synchronous machines (PMSMs). In six-phase control systems, the six-phase states are usually mapped onto three subspaces by vector space decomposition (VSD) and the behaviors in each subspace are influenced by ISCF. In the fault location methods, the phase angle of short-circuit current is usually estimated by inverse tangent function. In symmetrical six-phase PMSMs, there are three pairs of opposite phases. However, it is difficult to distinguish the opposite phases based on a high-harmonic signal due to the incomplete output range of inverse tangent function. In this paper, a novel fault location method based on the x-axis current residual is proposed to overcome this problem. The proposed method has a high signal-to-noise ratio and does not need any additional sensors or searching coils. Simulation and experimental results show the effectiveness of the proposed method.
- 25 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 10 (4) , 8336-8345
Fault Phase Location for Interturn Short-Circuit Faults in Symmetrical Six-Phase PMSMs Based on Subspace Current Residual
Fault location can also be called fault isolation which is an important task of fault diagnosis. This paper proposes a fault location method for interturn short circuit faults (ISCF) in symmetrical six-phase permanent magnet synchronous machines (PMSMs). In six-phase control systems, the six-phase states are usually mapped onto three subspaces by vector space decomposition (VSD) and the behaviors in each subspace are influenced by ISCF. In the fault location methods, the phase angle of short-circuit current is usually estimated by inverse tangent function. In symmetrical six-phase PMSMs, there are three pairs of opposite phases. However, it is difficult to distinguish the opposite phases based on a high-harmonic signal due to the incomplete output range of inverse tangent function. In this paper, a novel fault location method based on the x-axis current residual is proposed to overcome this problem. The proposed method has a high signal-to-noise ratio and does not need any additional sensors or searching coils. Simulation and experimental results show the effectiveness of the proposed method.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3613-3622
Interturn Fault Severity Monitoring in Symmetrical Six-Phase PMSMs Using Subspace Negative-Sequence High-Frequency Current Residuals
This article proposes a fault severity monitoring method for interturn short-circuit fault (ISCF) based on the xy subspace negative-sequence high-frequency (HF) current residuals in symmetrical six-phase permanent magnet synchronous machines. For six-phase machines, both the fundamental frequency and HF behaviors in the xy subspace can be used to design fault indicators. However, another fault type, high-resistance connection faults (HRCFs) can cause similar xy subspace fundamental current symptoms to ISCF. To avoid incorrectly identifying HRCF as ISCF, the proposed method uses the xy subspace negative-sequence HF current residuals to reduce the sensitivity to the HRCF. Moreover, the proposed method has high robustness for different work conditions and does not need additional sensors. Experimental results show the effectiveness of the proposed method for different fault severities and operations.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (3) , 3613-3622
Interturn Fault Severity Monitoring in Symmetrical Six-Phase PMSMs Using Subspace Negative-Sequence High-Frequency Current Residuals
This article proposes a fault severity monitoring method for interturn short-circuit fault (ISCF) based on the xy subspace negative-sequence high-frequency (HF) current residuals in symmetrical six-phase permanent magnet synchronous machines. For six-phase machines, both the fundamental frequency and HF behaviors in the xy subspace can be used to design fault indicators. However, another fault type, high-resistance connection faults (HRCFs) can cause similar xy subspace fundamental current symptoms to ISCF. To avoid incorrectly identifying HRCF as ISCF, the proposed method uses the xy subspace negative-sequence HF current residuals to reduce the sensitivity to the HRCF. Moreover, the proposed method has high robustness for different work conditions and does not need additional sensors. Experimental results show the effectiveness of the proposed method for different fault severities and operations.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2721-2730
Dynamic Modeling for Interturn Short Circuit Faults in Symmetrical Six-Phase FSCW-PMSMs With Unaligned Fault Coil
Comprehensive fault dynamic model is the basis of high-performance fault diagnosis and fault-tolerant control. This article proposes an interturn short circuit faults dynamic model considering the location of unaligned fault coil for symmetrical six-phase fractional slot concentrated-winding permanent magnet synchronous machines (FSCW-PMSMs). In FSCW-PMSMs, the coils in one phase winding are usually wound on two or more different stator teeth. Therefore, the axis of fault coil is not necessarily aligned with the axis of fault phase. Model parameters, such as inductances and back electromotive force in shorted turns change with the location of fault coils. The proposed model can be used to improve diagnosis strategies to detect more fault detail. Simulation and experimental results show that the proposed model has a high accuracy on the short circuit current.
- 31 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (2) , 2721-2730
Dynamic Modeling for Interturn Short Circuit Faults in Symmetrical Six-Phase FSCW-PMSMs With Unaligned Fault Coil
Comprehensive fault dynamic model is the basis of high-performance fault diagnosis and fault-tolerant control. This article proposes an interturn short circuit faults dynamic model considering the location of unaligned fault coil for symmetrical six-phase fractional slot concentrated-winding permanent magnet synchronous machines (FSCW-PMSMs). In FSCW-PMSMs, the coils in one phase winding are usually wound on two or more different stator teeth. Therefore, the axis of fault coil is not necessarily aligned with the axis of fault phase. Model parameters, such as inductances and back electromotive force in shorted turns change with the location of fault coils. The proposed model can be used to improve diagnosis strategies to detect more fault detail. Simulation and experimental results show that the proposed model has a high accuracy on the short circuit current.
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (12) , 16142-16152
Model-Based Severity Monitoring for Interturn Short Circuit Faults in Symmetrical Six-Phase PMSMs Using Subspace Current Residuals
This article proposes a novel model-based method for severity level monitoring of interturn short-circuit faults (ISCFs) using the xy subspace current residuals in symmetrical six-phase permanent magnet synchronous machines. For six-phase control system, the six-phase currents are usually mapped onto the dq and xy subspaces by vector space decomposition. The behavior in each subspace is affected by ISCF. In order to avoid PM flux linkage error reducing the performance of model-based method, the fault indicator is generated using the xy subspace current residuals. The proposed method has a high signal-to-noise ratio by extracting a fundamental signal instead of the second harmonic. Moreover, the proposed fault indicator can be obtained by simple signal processing without the use of spectral analysis tools or lots of filters. Experimental results show the effectiveness of proposed method for different fault severities and operating conditions.
- 12 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 38 (12) , 16142-16152
Model-Based Severity Monitoring for Interturn Short Circuit Faults in Symmetrical Six-Phase PMSMs Using Subspace Current Residuals
This article proposes a novel model-based method for severity level monitoring of interturn short-circuit faults (ISCFs) using the xy subspace current residuals in symmetrical six-phase permanent magnet synchronous machines. For six-phase control system, the six-phase currents are usually mapped onto the dq and xy subspaces by vector space decomposition. The behavior in each subspace is affected by ISCF. In order to avoid PM flux linkage error reducing the performance of model-based method, the fault indicator is generated using the xy subspace current residuals. The proposed method has a high signal-to-noise ratio by extracting a fundamental signal instead of the second harmonic. Moreover, the proposed fault indicator can be obtained by simple signal processing without the use of spectral analysis tools or lots of filters. Experimental results show the effectiveness of proposed method for different fault severities and operating conditions.
- 1 June 2020
- Published by Elsevier in Renewable Energy
- Vol. 153, 985-997
Evaluation of geothermal development considering proppant embedment in hydraulic fractures
- 1 June 2020
- Published by Elsevier in Renewable Energy
- Vol. 153, 985-997
Evaluation of geothermal development considering proppant embedment in hydraulic fractures