Paneetha Seneviratne
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paneetha Seneviratne has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Amal Nishantha Vadysinghe
Department of Forensic Medicine, Faculty of Medicine, University of Peradeniya, Peradeniya, Sri Lanka
2 shared publications - Bandarage Sanjaya
Department of Forensic Medicine, Faculty of Medicine, University of Peradeniya, Peradeniya, Sri Lanka
2 shared publications - Chathula Ushari Wickramasinghe
Department of Forensic Medicine Faculty of Medicine University of Peradeniya Peradeniya Sri Lanka
2 shared publications - Kasun Bandara Ekanayake
Department of Forensic Medicine, Faculty of Medicine, University of Peradeniya, Peradeniya, Sri Lanka
2 shared publications - Gayan Kumarasinghe
Department of Forensic Medicine, Faculty of Medicine, University of Peradeniya, Peradeniya, Sri Lanka
1 shared publication - Navodya Kumari Ekanayake
University of Peradeniya
1 shared publication
Latest Publications
- Open Access
- 28 May 2026
- Published by Uniwersytet Jagiellonski - Wydawnictwo Uniwersytetu Jagiellonskiego in Archives of Forensic Medicine and Criminology
- Vol. 76 (1) , 76-81
Fatal Electrocution of a Child During Kite Flying: A Case Report
Introduction: Kite flying is generally perceived as a harmless recreational activity, particularly among children. However, under certain environmental and physiological conditions, it may pose unexpected hazards. We present an unusual case of fatal pediatric electrocution that occurred during kite flying with a standard nylon thread, illustrating how specific circumstances can overcome the insulating properties typically attributed to such materials. Case Report: A previously healthy nine-year-old boy was flying a kite near a suburban roadway under adult supervision when the kite became entangled in an overhead 33,000-volt power line. While attempting to retrieve the kite, the child collapsed suddenly and became unresponsive. He was transported to the hospital, where he was pronounced dead on arrival. There was no reported history of direct contact with the electrical infrastructure other than through the kite string. Postmortem examination revealed localized burn injuries on the dorsal aspects of the right thumb and index finger, consistent with an electrical entry site. No definitive exit wounds were identified. Internal examination was unremarkable. Histopathological analysis of palmar skin demonstrated dermo-epidermal separation, elongation and streaming of epidermal nuclei, and homogenization of dermal collagen, findings characteristic of electrical injury. A history of longstanding palmar hyperhidrosis was obtained from the parents, raising the possibility that sweat saturation may have increased the electrical conductivity of the nylon thread. Conclusions: This case demonstrates a rare mechanism of fatal pediatric electrocution involving a sweat-saturated nylon kite thread, underscoring the complex interaction between physiological factors, environmental conditions, and material properties. It further highlights the need for increased public awareness regarding the hidden risks associated with kite flying in proximity to overhead power lines.
- 28 May 2026
- Published by Uniwersytet Jagiellonski - Wydawnictwo Uniwersytetu Jagiellonskiego in Archives of Forensic Medicine and Criminology
- Vol. 76 (1) , 76-81
Open AccessFatal Electrocution of a Child During Kite Flying: A Case Report
Introduction: Kite flying is generally perceived as a harmless recreational activity, particularly among children. However, under certain environmental and physiological conditions, it may pose unexpected hazards. We present an unusual case of fatal pediatric electrocution that occurred during kite flying with a standard nylon thread, illustrating how specific circumstances can overcome the insulating properties typically attributed to such materials. Case Report: A previously healthy nine-year-old boy was flying a kite near a suburban roadway under adult supervision when the kite became entangled in an overhead 33,000-volt power line. While attempting to retrieve the kite, the child collapsed suddenly and became unresponsive. He was transported to the hospital, where he was pronounced dead on arrival. There was no reported history of direct contact with the electrical infrastructure other than through the kite string. Postmortem examination revealed localized burn injuries on the dorsal aspects of the right thumb and index finger, consistent with an electrical entry site. No definitive exit wounds were identified. Internal examination was unremarkable. Histopathological analysis of palmar skin demonstrated dermo-epidermal separation, elongation and streaming of epidermal nuclei, and homogenization of dermal collagen, findings characteristic of electrical injury. A history of longstanding palmar hyperhidrosis was obtained from the parents, raising the possibility that sweat saturation may have increased the electrical conductivity of the nylon thread. Conclusions: This case demonstrates a rare mechanism of fatal pediatric electrocution involving a sweat-saturated nylon kite thread, underscoring the complex interaction between physiological factors, environmental conditions, and material properties. It further highlights the need for increased public awareness regarding the hidden risks associated with kite flying in proximity to overhead power lines.
- 12 September 2023
- Published by Springer Nature in Forensic Science, Medicine and Pathology
- Vol. 20 (3) , 1009-1013
A death due to faulty airbag system—case report
Injuries due to automobile safety devices have been reported and we report a rare fatality due to a defective airbag system. A compact hybrid car driven by a 37-year-old male at moderate speed had crashed through an unprotected manhole. The car had moved around 200 m before it came to a halt. The passers-by had noticed that the driver was unconscious, partly leaning forward with an inflated airbag. He was pronounced dead on admission. The car had sustained minor indentation on front bumper. Autopsy revealed a circular perforated laceration on the neck associated with completely transected right carotid artery and partially transected jugular vein. There was a 2 × 2-cm cylindrical metal object lodged at C4–C5 vertebrae level, and the remaining part of this was retrieved during scene investigation and identified as a part of a metal canister in the inflator component of the airbag system. There was a perforation in the airbag which was similar in size to the retrieved foreign body. The cause of death was ascertained as hemorrhagic shock due to bleeding from ruptured neck vessels caused by primary shrapnel projected from the faulty airbag system. Following the incident, the manufacturers replaced faulty airbag systems in similar models. If abnormally fatal injuries are observed, a scene visit along with automotive expert opinion would provide valuable insight into the incident. Such information would alert the general public on regular screening of safety measures and prompt manufacturers to recall faulty products.
- 12 September 2023
- Published by Springer Nature in Forensic Science, Medicine and Pathology
- Vol. 20 (3) , 1009-1013
A death due to faulty airbag system—case report
Injuries due to automobile safety devices have been reported and we report a rare fatality due to a defective airbag system. A compact hybrid car driven by a 37-year-old male at moderate speed had crashed through an unprotected manhole. The car had moved around 200 m before it came to a halt. The passers-by had noticed that the driver was unconscious, partly leaning forward with an inflated airbag. He was pronounced dead on admission. The car had sustained minor indentation on front bumper. Autopsy revealed a circular perforated laceration on the neck associated with completely transected right carotid artery and partially transected jugular vein. There was a 2 × 2-cm cylindrical metal object lodged at C4–C5 vertebrae level, and the remaining part of this was retrieved during scene investigation and identified as a part of a metal canister in the inflator component of the airbag system. There was a perforation in the airbag which was similar in size to the retrieved foreign body. The cause of death was ascertained as hemorrhagic shock due to bleeding from ruptured neck vessels caused by primary shrapnel projected from the faulty airbag system. Following the incident, the manufacturers replaced faulty airbag systems in similar models. If abnormally fatal injuries are observed, a scene visit along with automotive expert opinion would provide valuable insight into the incident. Such information would alert the general public on regular screening of safety measures and prompt manufacturers to recall faulty products.