Lorena Álvarez-Rodríguez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lorena Álvarez-Rodríguez has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Joaquim de Moura
Department of Computer Science and Information Technologies, Universidade da Coruña, A Coruña, Spain
6 shared publications - Marcos Ortega
Department of Computer Science and Information Technologies, Universidade da Coruña, A Coruña, Spain
5 shared publications - Jorge Novo
Grupo VARPA INIBIC Instituto de Investigacion Biomédica de A Coruña Universidade da Coruña 15006 A Coruña Spain
4 shared publications - Elena García-Martín
University Institute of Molecular Pathology Biomarkers, Universidad de Extremadura, 10071 Cáceres, Spain
2 shared publications Jorge Novo
2 shared publicationsAna M.D Macarro-Merino
Centro Internacional de Oftalmología Avanzada, Madrid, Spain
1 shared publication
Latest Publications
- Open Access
- 7 July 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- p. 1-27
3D OCT-Based Retinal Biomarker Analysis for Automatic Regional-Wise Characterization of Neurodegenerative Diseases
Neurodegenerative diseases (NDDs) such as Alzheimer’s disease (AD), essential tremor (ET), multiple sclerosis (MS), and Parkinson’s disease (PD) are complex disorders that often exhibit overlapping symptoms, leading to diagnostic challenges. Given the increasing interest in retinal imaging as a non-invasive biomarker for neurodegeneration, this study proposes a fully automated machine learning pipeline for disease characterization using optical coherence tomography (OCT). We analyze macular thickness patterns across three key and relevant retinal elements: retinal nerve fibre layer (RNFL), ganglion cell layer to Bruch’s membrane (GCL-BM), and the total retina. These are processed by two complementary regional layouts: the standard ETDRS scheme and a custom 3 $$\times $$ 3 quadrant grid. These measurements are used to train multiple classifiers to distinguish between healthy controls and NDDs either collectively or individually. The proposed method processes 34,375 OCT B-scans from 353 subjects and highlights disease-specific thickness patterns with a pathological distinction score ranging up to 0.71 depending on the retinal region, disease, and classifier. Sector-based grids generally outperform quadrant-based ones, revealing highly localized pathological signatures. Our findings demonstrate that each disease manifests distinct retinal alterations, aligning with current clinical literature while offering novel insights for ET and PD. The study reinforces the potential of grid-based OCT analysis as a discriminative and fully automatic screening tool, paving the way for improved early diagnosis and differential analysis of NDDs through retinal biomarkers.- 7 July 2026
- Published by Springer Nature in Journal of Imaging Informatics in Medicine
- p. 1-27
Open Access3D OCT-Based Retinal Biomarker Analysis for Automatic Regional-Wise Characterization of Neurodegenerative Diseases
Neurodegenerative diseases (NDDs) such as Alzheimer’s disease (AD), essential tremor (ET), multiple sclerosis (MS), and Parkinson’s disease (PD) are complex disorders that often exhibit overlapping symptoms, leading to diagnostic challenges. Given the increasing interest in retinal imaging as a non-invasive biomarker for neurodegeneration, this study proposes a fully automated machine learning pipeline for disease characterization using optical coherence tomography (OCT). We analyze macular thickness patterns across three key and relevant retinal elements: retinal nerve fibre layer (RNFL), ganglion cell layer to Bruch’s membrane (GCL-BM), and the total retina. These are processed by two complementary regional layouts: the standard ETDRS scheme and a custom 3 $$\times $$ 3 quadrant grid. These measurements are used to train multiple classifiers to distinguish between healthy controls and NDDs either collectively or individually. The proposed method processes 34,375 OCT B-scans from 353 subjects and highlights disease-specific thickness patterns with a pathological distinction score ranging up to 0.71 depending on the retinal region, disease, and classifier. Sector-based grids generally outperform quadrant-based ones, revealing highly localized pathological signatures. Our findings demonstrate that each disease manifests distinct retinal alterations, aligning with current clinical literature while offering novel insights for ET and PD. The study reinforces the potential of grid-based OCT analysis as a discriminative and fully automatic screening tool, paving the way for improved early diagnosis and differential analysis of NDDs through retinal biomarkers. - Open Access
- 20 August 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 112
Automatic identification of neurodegenerative diseases with 3D point cloud-based analysis using geometric deep learning in OCT retinal images
- 20 August 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 112
Open AccessAutomatic identification of neurodegenerative diseases with 3D point cloud-based analysis using geometric deep learning in OCT retinal images
- Open Access
- 26 January 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 104
Heatmap-guided balanced multi-task learning approach for glistening characterization in OCT images
- 26 January 2025
- Published by Elsevier in Biomedical Signal Processing and Control
- Vol. 104
Open AccessHeatmap-guided balanced multi-task learning approach for glistening characterization in OCT images
- Open Access
- 1 November 2024
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 158, 103006
Fully automatic deep convolutional approaches for the screening of neurodegeneratives diseases using multi-view OCT images
- 1 November 2024
- Published by Elsevier in Artificial Intelligence in Medicine
- Vol. 158, 103006
Open AccessFully automatic deep convolutional approaches for the screening of neurodegeneratives diseases using multi-view OCT images
- Open Access
- 28 October 2024
- Published by Qeios Ltd
Review of: "Mastering Artifact Correction in Neuroimaging Analysis: A Retrospective Approach"
It is a very well-written and structured work. I have some comments to further improve its quality: * The acronym MOANA is not explained. * The dataset used contains pathological samples, but assuming the framework is designed to reconstruct any t...
- 28 October 2024
- Published by Qeios Ltd
Open AccessReview of: "Mastering Artifact Correction in Neuroimaging Analysis: A Retrospective Approach"
It is a very well-written and structured work. I have some comments to further improve its quality: * The acronym MOANA is not explained. * The dataset used contains pathological samples, but assuming the framework is designed to reconstruct any t...
- 1 January 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (1) , 37-42
Comparative study of the glistening between four intraocular lens models assessed by OCT and deep learning
Purpose: To evaluate the glistening in 4 different models of intraocular lenses (IOLs) using optical coherence tomography (OCT) and deep learning (DL). Setting: Centro Internacional de Oftalmología Avanzada (Madrid, Spain). Design: Cross-sectional study. Methods: 325 eyes were assessed for the presence and severity of glistening in 4 IOL models: ReSTOR+3 SN6AD1 (n = 41), SN60WF (n = 110), PanOptix TFNT (n = 128) and Vivity DFT015 (n = 46). The presence of glistening was analyzed using OCT, identifying the presence of hyperreflective foci (HRF) in the central area of the IOL. A manual and an original DL-based quantification algorithm designed for this purpose was applied. Results: Glistening was detected in 22 (53.7%) ReSTOR SN6AD1, 44 (40%) SN60WF, 49 (38.3%) PanOptix TFNT, and 4 (8.7%) Vivity DFT015 IOLs, when any grade was considered. In the comparison of the different types of IOLs, global glistening measured as total HRF was 17.3 ± 25.9 for the ReSTOR+3; 9.3 ± 15.7 for the SN60WF; 6.9 ± 10.5 for the PanOptix; and 1.2 ± 2.6 for the Vivity (P < .05). There was excellent agreement between manual and DL-based quantification (≥0.829). Conclusions: It is possible to quantify, classify and compare the glistening severity in different IOL models using OCT images in a simple and objective manner with a DL algorithm. In the comparative study, the Vivity presented the lowest severity of glistening.
- 1 January 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (1) , 37-42
Comparative study of the glistening between four intraocular lens models assessed by OCT and deep learning
Purpose: To evaluate the glistening in 4 different models of intraocular lenses (IOLs) using optical coherence tomography (OCT) and deep learning (DL). Setting: Centro Internacional de Oftalmología Avanzada (Madrid, Spain). Design: Cross-sectional study. Methods: 325 eyes were assessed for the presence and severity of glistening in 4 IOL models: ReSTOR+3 SN6AD1 (n = 41), SN60WF (n = 110), PanOptix TFNT (n = 128) and Vivity DFT015 (n = 46). The presence of glistening was analyzed using OCT, identifying the presence of hyperreflective foci (HRF) in the central area of the IOL. A manual and an original DL-based quantification algorithm designed for this purpose was applied. Results: Glistening was detected in 22 (53.7%) ReSTOR SN6AD1, 44 (40%) SN60WF, 49 (38.3%) PanOptix TFNT, and 4 (8.7%) Vivity DFT015 IOLs, when any grade was considered. In the comparison of the different types of IOLs, global glistening measured as total HRF was 17.3 ± 25.9 for the ReSTOR+3; 9.3 ± 15.7 for the SN60WF; 6.9 ± 10.5 for the PanOptix; and 1.2 ± 2.6 for the Vivity (P < .05). There was excellent agreement between manual and DL-based quantification (≥0.829). Conclusions: It is possible to quantify, classify and compare the glistening severity in different IOL models using OCT images in a simple and objective manner with a DL algorithm. In the comparative study, the Vivity presented the lowest severity of glistening.
- Open Access
- 28 April 2022
- Published by Springer Nature in BMC Medical Research Methodology
- Vol. 22 (1) , 1-17
Does imbalance in chest X-ray datasets produce biased deep learning approaches for COVID-19 screening?
Background: The health crisis resulting from the global COVID-19 pandemic highlighted more than ever the need for rapid, reliable and safe methods of diagnosis and monitoring of respiratory diseases. To study pulmonary involvement in detail, one of the most common resources is the use of different lung imaging modalities (like chest radiography) to explore the possible affected areas. Methods: The study of patient characteristics like sex and age in pathologies of this type is crucial for gaining knowledge of the disease and for avoiding biases due to the clear scarcity of data when developing representative systems. In this work, we performed an analysis of these factors in chest X-ray images to identify biases. Specifically, 11 imbalance scenarios were defined with female and male COVID-19 patients present in different proportions for the sex analysis, and 6 scenarios where only one specific age range was used for training for the age factor. In each study, 3 different approaches for automatic COVID-19 screening were used: Normal vs COVID-19, Pneumonia vs COVID-19 and Non-COVID-19 vs COVID-19. The study was validated using two public chest X-ray datasets, allowing a reliable analysis to support the clinical decision-making process. Results: The results for the sex-related analysis indicate this factor slightly affects the system in the Normal VS COVID-19 and Pneumonia VS COVID-19 approaches, although the identified differences are not relevant enough to worsen considerably the system. Regarding the age-related analysis, this factor was observed to be influencing the system in a more consistent way than the sex factor, as it was present in all considered scenarios. However, this worsening does not represent a major factor, as it is not of great magnitude. Conclusions: Multiple studies have been conducted in other fields in order to determine if certain patient characteristics such as sex or age influenced these deep learning systems. However, to the best of our knowledge, this study has not been done for COVID-19 despite the urgency and lack of COVID-19 chest x-ray images. The presented results evidenced that the proposed methodology and tested approaches allow a robust and reliable analysis to support the clinical decision-making process in this pandemic scenario.
- 28 April 2022
- Published by Springer Nature in BMC Medical Research Methodology
- Vol. 22 (1) , 1-17
Open AccessDoes imbalance in chest X-ray datasets produce biased deep learning approaches for COVID-19 screening?
Background: The health crisis resulting from the global COVID-19 pandemic highlighted more than ever the need for rapid, reliable and safe methods of diagnosis and monitoring of respiratory diseases. To study pulmonary involvement in detail, one of the most common resources is the use of different lung imaging modalities (like chest radiography) to explore the possible affected areas. Methods: The study of patient characteristics like sex and age in pathologies of this type is crucial for gaining knowledge of the disease and for avoiding biases due to the clear scarcity of data when developing representative systems. In this work, we performed an analysis of these factors in chest X-ray images to identify biases. Specifically, 11 imbalance scenarios were defined with female and male COVID-19 patients present in different proportions for the sex analysis, and 6 scenarios where only one specific age range was used for training for the age factor. In each study, 3 different approaches for automatic COVID-19 screening were used: Normal vs COVID-19, Pneumonia vs COVID-19 and Non-COVID-19 vs COVID-19. The study was validated using two public chest X-ray datasets, allowing a reliable analysis to support the clinical decision-making process. Results: The results for the sex-related analysis indicate this factor slightly affects the system in the Normal VS COVID-19 and Pneumonia VS COVID-19 approaches, although the identified differences are not relevant enough to worsen considerably the system. Regarding the age-related analysis, this factor was observed to be influencing the system in a more consistent way than the sex factor, as it was present in all considered scenarios. However, this worsening does not represent a major factor, as it is not of great magnitude. Conclusions: Multiple studies have been conducted in other fields in order to determine if certain patient characteristics such as sex or age influenced these deep learning systems. However, to the best of our knowledge, this study has not been done for COVID-19 despite the urgency and lack of COVID-19 chest x-ray images. The presented results evidenced that the proposed methodology and tested approaches allow a robust and reliable analysis to support the clinical decision-making process in this pandemic scenario.