AJAnil Jakhar

Anil Jakhar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Anil Jakhar has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fuel Cell Railway Tower Car: Efficiency, Cost, and Performance Analysis

    by Rajbala Purnima Priya, Sanjay Kumar Kakodia, Amarendra Edpuganti, Masoud Karimi-Ghartemani, S. Ali Khajehoddin, Anil Jakhar, Prabodh Bajpai

  • A Five-Level Integrated Common-Ground-Type Inverter With Dynamic Voltage-Gain

    by Anil Jakhar, N. Sandeep

    This article proposes a five-level (5L) inverter that combines the benefits of the DC-DC boost converter and the common-ground-type (CGT) inverter in a single-stage conversion. On contrary to the majority of the established CGT inverters, the proposed topology features continuous input current (non-zero) with dynamic voltage-boosting gain. Additionally, the proposed inverter eliminates ground leakage current caused by photovoltaic parasitic capacitance because of the common ground feature. It requires lower voltage rating capacitors, i.e., half of the inverter’s peak output voltage, and is self-voltage-balanced, and reduced control complexity. It will be demonstrated that the voltage stress of semiconductor devices, the number of conducting switches, and switching transitions are the least, resulting in lower power losses. The circuit description and its operation are explained in detail. A comparative assessment is carried out to highlight the salient features of the proposed topology against its counterparts. From the comparative analysis, the above-mentioned salient features of the proposed topology will be established. The experiment results for grid-connected operation demonstrate the proposed inverter’s viability and feasibility. Furthermore, the proposed 5L CGT inverter has fault-tolerant capability unlike other recent CGT inverters; it can sustain the inverter operation in post-fault operation and is capable of supplying partial/full load power.


  • Switched-Capacitor-Based DC–AC Boosting Circuit: Synthesis and Operation

    by Anil Jakhar, N. Sandeep

    The novel inverter topologies are often intriguing and ignite interest in knowing the rationale behind their circuit synthesis, which is usually not detailed. This article provides a step-by-step topological derivation of a novel common ground (CG) multilevel inverter with an aim to motivates researchers for proposing new attractive topologies applicable to emerging fields. Further, this article proposes a dual-output, nine-level boosting inverter that combines CG and common-positive (CP) features. By integrating the CGCP characteristics, the proposed inverter draws a non-zero continuous input current (unlike the traditional CG or CP-based inverter), making it highly suitable for photovoltaic (PV) systems. With the CGCP feature, the proposed inverter eliminates ground leakage current caused by PV parasitic capacitance. In addition, the usage of switched-capacitors (SCs) inherently boosts the input voltage. Further, the SCs are self-voltage balanced without relying on a dedicated sensor circuit, reducing the control complexity. Unlike the conventional dual port CG inverters, the proposed CG and CP inverters are fault-tolerant as an independent unit and in combination as well. The decoupled output ports feed the loads independently of each other, thus, can also feed unequal loads. A detailed comparative study is presented to highlight the figures of merit of the proposed inverter against the well-established topologies. Finally, the feasibility of the proposed inverter is validated through several experimental tests conducted on a 1 kW laboratory prototype, and the results are presented.


  • Switched-Capacitor-Based Seven-Level Boosting Inverter With Reduced Voltage Stress for Grid-Connected Photovoltaic Applications

    by Anil Jakhar, N. Sandeep

    This article proposes a seven-level common-ground -type (CGT) transformer-less inverter with a boosting feature for solar photovoltaic (PV) applications. The proposed topology's common ground feature eliminates the crucial ground leakage current caused by the varying common mode voltage in grid-connected PV inverters. Unlike the conventional and recent CGT inverters, the proposed inverter requires only two capacitors of voltage rating lower than the inverter's peak output voltage. Thereby, the semiconductor devices experience reduced voltage stress resulting in lower power losses. Further, the circuit description and operating principle are presented in detail. The detailed comparative assessment of the proposed and its counterpart topologies is carried out to highlight the superior features of the former such as lower component count, least average number of conducting devices, fewest number of devices in the charging path, self-voltage balancing of the capacitors and reduced capacitor voltage diversity factor. In addition, it will be shown that the proposed inverter cost and footprint requirements are lesser than the available competent solutions. Furthermore, a detailed reliability assessment with fault tolerant operation is presented. Finally, the experimental results of the proposed inverter's grid-connected and stand-alone operations are elucidated to validate its feasibility.


  • An Improved Re-configurable Buck Converter with Enhanced Effective Switching Frequency

    by Shubham Parashar, Anil Jakhar, Shorabh Singh Gavar, N. Sandeep

  • Common-Ground-Type Quadruple Boosting Nine-Level Inverter

    by Anil Jakhar, N. Sandeep, Arun Kumar Verma

    Transformerless multilevel inverters with boosting features are widely used in residential and commercial photovoltaic applications due to their advantages such as compact size, low cost, high voltage gain, and higher efficiency. However, they suffer from ground leakage current, which degrades power quality and poses safety issues. In this paper, a nine-level quadruple-boost inverter with common ground is proposed using the concept of switched capacitor (SC). Due to the common ground, the proposed topology eliminates the leakage current. The voltages of SC are self-balancing without the need for external dedicated circuits or sensors. The operating principle of the proposed topology is described in detail, followed by the design guidelines for sizing SC. The comparative summary highlights the advantageous features of the proposed topology, including fewer components, high gain, self-balancing capability of SCs, lower conduction and switching losses, and near-zero leakage current. In addition, through a detailed volume and cost-based comparison, it will be shown that the proposed topology has the lowest volume (278.95 cm $^{3}$ ) and cost (114.81 $) amongst its counterparts. Further, the performance of the proposed topology is validated through several experiments on a 1 kW laboratory prototype, and the results are presented for grid-connected and stand-alone modes.


  • Seven-Level Common-Ground-Type Inverter With Reduced Voltage Stress

    by Anil Jakhar, N. Sandeep, Arun Kumar Verma

    Transformer-less inverters (TIs) are widely used in solar photovoltaic (PV) applications due to their high power density, low dv/dt stress, low cost, and higher efficiency. The fundamental concern with TIs is the ground leakage current. This article proposes seven-level transformer-less common-ground (CG) inverter with a three-fold gain for synthesizing a seven-level output waveform using switched capacitors (SCs) with a single input source. Due to the CG connection, the proposed inverter can eliminate the ground leakage current. Also, the proposed topology requires a lower conducting devices, which minimizes conduction losses. The voltage across all of the SCs is self-balanced in every fundamental cycle. Therefore, the need for sensors and complex control circuits is eliminated. In addition, the operating modes, SCs design, and power losses are discussed in detail. Furthermore, the experimental results are presented to verify the proposed topology’s theoretical concept, grid-operation, and feasibility. Finally, an exhaustive comparative analysis against state-of-the-art topologies is carried out to highlight the proposed topology’s benefits.


  • Common-Ground-Type Inverter Topology With Low Voltage Stress and Boosting Ability

    by Anil Jakhar, N. Sandeep, Arun Kumar Verma

    This article proposes a seven-level transformer-less common ground-type inverter topology with a three-fold voltage gain. Due to the common ground, the proposed inverter eliminates the photovoltaic ground leakage current due to parasitic capacitance. The proposed topology employs only two capacitors with reduced voltage ratings, which enhances reliability and lowers the overall cost. The capacitors impress less stress on the semiconductor devices. Further, the capacitor voltages are self-balanced, ensuring sensor-less operation. Additionally, the proposed inverter requires the lowest number of conducting devices, resulting in lower conduction losses. The circuit description and operating principle are deliberated in detail. A comparison with other similar inverters is included, and from the results, it will be shown that the proposed inverter has the lowest total standing voltage as compared to others with the same performance and boosting gain. The comparative summary also includes an exclusive cost and volume based assessment to prove the practicality of the proposed topology. Finally, the experimental results of the proposed inverter are presented under steady-state and dynamic conditions in grid-connected and stand-alone modes to validate its feasibility.


  • A Five-Level X-Type Boosting Inverter With Reduced Stored Energy of Switched-Capacitors

    by Anil Jakhar, N. Sandeep, Arun Kumar Verma

    This brief proposes a novel five-level (5L) common ground type (CGT) inverter based on switched capacitors (SCs) with dual voltage boosting ability. In the conventional 5L CGTs, using a capacitor rated for peak output voltage is inevitable, negatively affecting the inverter’s power density. In the proposed topology, the SCs are rated for half of the peak output voltage, resulting in a lower voltage diversity factor and reduced energy storage requirement. Further, in case of any capacitor failures, the proposed inverter can sustain operation with reduced voltage levels. In addition, the proposed topology features SC self-voltage balancing, low dv/dt, and sensorless operation. The circuit description and operating principle of the proposed inverter are detailed. A comparative assessment of the state-of-the-art CGT topologies with the proposed inverter is presented to emphasize the distinctive features of the proposed inverter. Finally, the operation and feasibility of the proposed inverter is validated through experiments on a laboratory prototype, and the results are presented for stand-alone and grid-connected operation.